Nortel Networks 5000BH manual Token Ring Connections, Port types for the TokenSpeed module

Page 34

Using the 8-port TokenSpeed and TokenSpeed/MCP Switch Modules

Token Ring Connections

When you connect a network device to a token ring port on the TokenSpeed module, you must specify a TokenSpeed port type using SpeedView. The port type setting is based on the type of network connection you are connecting to the TokenSpeed module. Table 3-1 shows the types of network connections and the correct port type for each.

Table 3-1. Port types for the TokenSpeed module

Network device port

TokenSpeed port type

 

 

Lobe port on token ring hub

Station

Lobe port on IBM 8228 MAU or similar device

Station

Station port on a network interface card (NIC)

Hub

in a server, PC, or router

 

RI port on a Bay Networks token ring hub

Bay/SNPX RO

RO port on a Bay Networks token ring hub

RI–other

 

Note: The RO port type on the

 

Bay Networks hub must be set as

 

Other.

RI port on a non-Bay Networks token ring hub

RO–other

RO port on a non-Bay Networks token ring hub

RI–other

 

 

To make the connection, use a straight-through cable with an RJ-45 connector on one end (see Figure 3-6) and an appropriate connector for the network device on the other end. For cable specifications and connector pin assignments, see Appendix B, “Cables.”

5634

Figure 3-6. Connecting a cable to an RJ-45 port on the TokenSpeed module

3-6

893-01019-A

Image 34
Contents Using the 8-port TokenSpeed TokenSpeed/MCP Switch Modules Trademarks Statement of ConditionsVoluntary Control Council for Interference Vcci Statement Iii893-01019-A 893-01019-A 893-01019-A Contents Chapter Installing and Connecting the TokenSpeed Module Figures Figure B -11. RI-other to RO connection RJ-45 to DB-9 Tables Xii Purpose PrefaceAudience Conventions Two-tiered Procedure FormatSpecial Message Formats Related publications Related PublicationsOrdering Bay Networks Publications Title DescriptionBay Networks Customer Support How to Get HelpTechnical Solutions Center Telephone number Fax number Region Telephone number Fax numberFor More Information 893-01019-A Chapter Overview of the TokenSpeed Module About the TokenSpeed ModuleFeatures TokenSpeed Module Ports and ConnectivityCaching and Proxy Fault ToleranceFiltering Network ManagementHardware features of the TokenSpeed module Physical DescriptionChapter TokenSpeed Module Applications Giving a Server a Dedicated PortSegmenting a Ring Giving a server a dedicated portConnecting a Segment Through the RI or RO Port Connecting a ring segment through an RI/RO port ring segmentConnecting a Segment Using a Lobe Port Connecting ring segments through lobe portsReplacing a Source Route Bridge or Router Concentrating Rings into a RouterConcentrating multiple rings into a router Installing and Connecting the TokenSpeed Module Preparing for InstallationInstalling the TokenSpeed Module Removing a filler panel Slot module guides Connecting Cables to TokenSpeed Ports Seating the modulePort types for the TokenSpeed module Token Ring ConnectionsNetwork device port TokenSpeed port type Verifying the Installation Management ConnectionTokenSpeed Module LEDs LED Switch Startup SequenceLED name Meaning Parameter Factory default Possible settings Factory default configuration settingsConfiguring the TokenSpeed Module FFE Removing and Replacing a Module Replacing a TokenSpeed/MCP Module Loosening the TokenSpeed moduleSlide the module out of the chassis see Figure Replacing a TokenSpeed Module 11. Loosening the TokenSpeed module12. Removing the module from the Centillion chassis Page Troubleshooting the TokenSpeed Module Switch Startup Failure with TokenSpeed/MCP TokenSpeed Module Startup Failure Port Insertion Problems Verify that the cabling is correctTroubleshooting the TokenSpeed Module Page Appendix a Technical Specifications Environmental Specifications Safety Agency ApprovalsConnectors Electromagnetic EmissionsAppendix B Cables Cable Types Port TypesTable B-1 Port types for the TokenSpeed module Cable type Mb/s 16 Mb/s UTP cable type Token Ring Connectors on the TokenSpeed ModuleTable B-2 Cable distances STP cable typeCable and Connector Pin Assignments Figure B-2. Connectors for token ring network cablesRJ-45 to RJ-45 Connection Figure B-3. Hub to station connection RJ-45 to RJ-45Figure B-4. Station to hub connection RJ-45 to RJ-45 Figure B-6. RI-other to RO connection RJ-45 to RJ-45 RJ-45 to DB-9 Connection Figure B-8. Hub to station connection RJ-45 to DB-9Figure B-9. Station to hub connection RJ-45 to DB-9 Figure B-11. RI-other to RO connection RJ-45 to DB-9 RJ-45 to IBM Type 1 Connection Figure B-13. Station to hub connection RJ-45 to IBM TypeFigure B-14. Bay/SNPX RO to RI connection RJ-45 to IBM Type Male Mini DIN 8 to male DB-25 cable Male Mini DIN Signal Male DB-25 Pin locations Pin numbersSerial MCP Connections Table B-3Request to send Clear to send Ring indicator Table B-4 Female DB-25 to female DB-9 adapterIndex Types, B-2 caching, RIFIndex-2 Index-3