Nortel Networks NN43001-318 manual Bk-G Tx+ Bk-Br

Page 72

72Configuring ISDN BRI hardware

 

 

 

 

Connector

 

 

 

 

 

 

pin number

Wire

 

SILC port

UILC port

and wire

color

 

signals

signals

color code

codes

Card ports

 

 

 

 

 

 

 

6

TX-

6

T

38

BK-G

 

6

TX+

6

R

13

G-BK

 

6

RX-

 

 

39

BK-BR

Port 6

6

RX+

 

 

14

BR-BK

 

 

 

 

 

 

 

 

7

TX-

7

T

40

BK-S

 

7

TX+

7

R

15

S-BK

 

7

RX-

 

 

41

Y-BL

Port 7

7

RX+

 

 

16

BL-Y

 

Note: The cable pair designated TX- TX+ is the transmit pair and the pair designated RX+ RX- is the receive pair of the S/T interface. The cable pair designated T R is the Tip and Ring of the 2B1Q full-duplex U interface.

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318 01.02 Standard

Release 5.0 20 June 2007

Copyright © 2003-2007, Nortel Networks

Image 72
Contents Isdn Basic Rate Interface Installation and Commissioning Page June MayAugust SeptemberRevision history Contents Generating traffic reports Contents Contents About this document SubjectApplicable systems System migrationIntended audience ConventionsRelated information TerminologyOnline CD-ROMContents Preparing the siteUnpacking and inspecting Taking inventoryInstalling Isdn BRI hardware Installing Isdn BRI hardware for line applicationsTo install Isdn BRI cards, perform the following steps Procedure Selecting the card slotsMISPs BRSCsSILCs/UILCs NT8D37 IPE module NT8D35 Network module Large SystemNT8D37 IPE module Large System NT4N41 Core/Network module Large SystemProcedure Remove the module cover for card installation Module cover locking latchesProcedure Installing the Misp Procedure Removing the MispProcedure Installing the BRSC, SILC, and Uilc Procedure Remove the BRSC, SILC, and Uilc Procedure Connecting Isdn BRI terminals to the systemStep Action End SILC/UILC port designations at the MDF Connect the system to the MDFInstalling Isdn BRI hardware for line applications Cross-connecting the MDF Step Action End Cross-connect the Silc port to the office wiring Cross-connect the Uilc port to the office wiring Silc Uilc Pairs Pair color PortPort signals Panel connectors Card Connecting the Isdn BRI terminals to the DSL Connecting the terminating resistors Procedure Connecting the Isdn BRI terminals to the DSLConnect the Isdn BRI terminal to the S/T interface Installing Isdn BRI hardware for trunk applications Removing the module cover for card installation Installing the MispInstalling the clock reference on the Silc Procedure Providing clock referencing on the SilcConnecting clock reference cables Isdn BRI clock reference tables Code Length feet UseClock recovery Procedure Connecting clock reference cablesClock reference cable connection Installing the Silc and the Uilc Connecting the system to the Main Distribution Frame MDFCross-connecting the Main Distribution Frame MDF Installing Isdn BRI hardware for trunk applications SILC/UILC or Brsc Number Slot number Connector Ports Card location formsSILC/UILC or Brsc Installing Isdn BRI hardware for trunk applications Installing Isdn BRI hardware Introduction Verifying Isdn BRI operationSetting up Isdn BRI test terminals and trunks Set up Isdn BRI terminalsProcedure Performing acceptance testing Set up Isdn BRI trunking Local Exchange connectivity Isdn BRI acceptance testing setup for terminalsSet up Isdn BRI trunking TIE trunk connectivity Setting up Isdn BRI test terminals and trunks Preparing the system Hardware requirements Line and packet data applicationsIsdn BRI trunking Hardware Product code DescriptionNTAK20AB Installation procedures SummaryCorrect responses to Loop and Misp prompts in LD Cabinet SystemsInstallation procedures Installation procedures Silc is not Silc is cloc See Note Clock reference ReferenceRemove the cover from the system 60 Configuring Isdn BRI hardware Procedure Installing the SILCs and UILCs Remove the cover from the assigned systemSilc line power options Jumper plug settings for normal power on the TX and RX leads Procedure Removing the Silc and Uilc Procedure Installing the PRI hardwareConnecting the Isdn BRI terminals for line applications 66 Configuring Isdn BRI hardware End 68 Configuring Isdn BRI hardware Installation procedures Uilc port designation label at the cross-connect terminal TX+ BL-W BK-G TX+ BK-BR Cross-connecting a Silc port to the office wiring 74 Configuring Isdn BRI hardware Interface connector specification RJ45 jack Pin signal name Signal name76 Configuring Isdn BRI hardware End Connecting the Isdn BRI terminal to the S/T interface Connecting the Isdn network terminator to the U interface Procedure Initializing a Nortel Networks M5317TDX terminal M5317TDX terminal error codes Error Code Number Description No valid voice SpidConnecting the Isdn BRI trunks for trunking applications Error Code Number DescriptionEnd Cross-connecting an Silc port Cross-connecting a Uilc port 86 Configuring Isdn BRI hardware Testing Isdn BRI functions Procedure Performing a call hold test Voice callsCall Hold Procedure Perform a Call Waiting test Call WaitingFeature Fundamentals NN43001-580 Call Forward No AnswerProcedure Performing a Call Forward No Answer test Calling Line Identification Presentation and RestrictionIsdn BRI Conference National ISDN-1 and Etsi Procedure Perform an Isdn BRI Conference test Procedure Perform a Call Join test on Conference Isdn BRI Special Hunting Procedure Perform a hunting test Isdn BRI National ISDN-1 Call Forward All Calls Isdn BRI Etsi Call Forwarding Unconditional Circuit-switched data calls Procedure Perform a circuit-switched data call testPacket data transmission Packet data transmission End Testing an Isdn BRI trunk Removing the test setupProcedure Perform procedure to test an Isdn BRI trunk DSL Testing Isdn BRI functions Generating traffic reports Option Meaning Network traffic reportNetwork traffic report Page Isdn Basic Rate Interface Installation and Commissioning

NN43001-318 specifications

Nortel Networks NN43001-318 is a sophisticated telecommunications component that plays a pivotal role in networking technologies. Designed for high-performance networking environments, this modular circuit pack is part of Nortel's long-standing reputation for reliability and efficiency in communication systems.

One of the standout features of the NN43001-318 is its support for advanced digital processing capabilities, which allows for the seamless transmission of data across various network formats. This circuit pack serves as a bridge between legacy systems and modern digital infrastructures, facilitating smooth upgrades and integration. Its versatility makes it suitable for a range of networking applications, from small businesses to large enterprises.

The NN43001-318 is equipped with multiple interfaces, allowing it to connect with various types of network equipment effortlessly. This characteristic is particularly advantageous for organizations looking to expand their network capabilities without a complete overhaul. The modular nature of the component ensures that it can be easily replaced or upgraded, thus prolonging the lifespan of overall network systems.

In terms of technological advancements, the NN43001-318 leverages multiple protocols to ensure reliable communications across diverse platforms. It supports Voice over IP (VoIP) technologies, which enhances the quality of voice communications while reducing costs associated with traditional telephony. Additionally, the circuit pack is designed to minimize latency, making it ideal for real-time applications where speed and efficiency are critical.

Security is another integral aspect of the NN43001-318, supporting encryption protocols to secure data transmission. This is essential in today's environment, where cybersecurity concerns are paramount. The combination of advanced encryption and robust processing power ensures that sensitive information remains protected, giving organizations peace of mind.

Moreover, the NN43001-318 aids in improving network management through its built-in diagnostic capabilities. These features allow network administrators to monitor performance and troubleshoot potential issues proactively, enhancing overall service quality.

In summary, Nortel Networks NN43001-318 is a versatile and powerful circuit pack that embodies the cutting-edge technologies required for modern networking. Its ability to support various protocols, combined with secure communications and efficient management features, makes it a valuable asset for any organization looking to enhance its networking infrastructure.