84Configuring ISDN BRI hardware
Refer to Table 16 "SILC and UILC port assignments connectors at
3Identify the trunk wiring facilities connected at the
4
5Repeat this procedure for each DSL.
Note: For the system DSL in TE mode, reverse the TX and RX pairs as shown in Figure 32 "Connecting the ISDN network terminator to the U interface and to the S/T interface (in TE mode)" (page 86). Maintain the same polarity on the Tip and Ring pins as for line application. Rewire the selected TX and RX pairs to exchange their TX pairs with RX pair position. This procedure is required since SILC cards are designed for applications in the NT mode.
—End—
Figure 30
Cross-connecting an SILC port
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
Release 5.0 20 June 2007
Copyright ©