Nortel Networks NN43001-318 manual Installing Isdn BRI hardware

Page 15

15

Installing ISDN BRI hardware

Contents

This section contains information on the following topics:

"Installing ISDN BRI hardware for line applications" (page 15) "Installing ISDN BRI hardware for trunk applications" (page 38)

"Selecting the card slots" (page 39)

"Removing the module cover for card installation" (page 39) "Installing the MISP" (page 39)

"Installing the clock reference on the SILC" (page 39) "Installing the SILC and the UILC" (page 42)

"Connecting the system to the Main Distribution Frame (MDF)" (page 42) "Cross-connecting the Main Distribution Frame (MDF)" (page 42)

"Card location forms" (page 44)

Installing ISDN BRI hardware for line applications

The following lists the procedures for installing ISDN BRI hardware for line applications. The system must already be installed and operating according to the instructions in Communication Server 1000M and Meridian 1 Large System Installation and Commissioning (NN43021-310)before performing these procedures.

For a successful installation, perform these procedures in the order listed below:

Step Action

1Select the card slots where the ISDN BRI cards will be located.

2Remove the module cover for card installation.

3Install the Multi-Purpose ISDN Signaling Processors (MISPs).

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318 01.02 Standard

Release 5.0 20 June 2007

Copyright © 2003-2007, Nortel Networks

Image 15 Contents
Isdn Basic Rate Interface Installation and Commissioning Page September JuneMay AugustRevision history Contents Generating traffic reports Contents Contents Subject About this documentSystem migration Applicable systems Terminology Intended audience Conventions Related informationCD-ROM OnlinePreparing the site ContentsTaking inventory Unpacking and inspectingInstalling Isdn BRI hardware for line applications Installing Isdn BRI hardwareProcedure Selecting the card slots To install Isdn BRI cards, perform the following stepsMISPs BRSCsSILCs/UILCs NT8D35 Network module Large System NT8D37 IPE moduleNT4N41 Core/Network module Large System NT8D37 IPE module Large SystemModule cover locking latches Procedure Remove the module cover for card installationProcedure Removing the Misp Procedure Installing the MispProcedure Installing the BRSC, SILC, and Uilc Procedure Connecting Isdn BRI terminals to the system Procedure Remove the BRSC, SILC, and UilcStep Action End Connect the system to the MDF SILC/UILC port designations at the MDFInstalling Isdn BRI hardware for line applications Cross-connecting the MDF Step Action End Cross-connect the Silc port to the office wiring Cross-connect the Uilc port to the office wiring Pairs Pair color Port Silc UilcPort signals Panel connectors Card Connecting the Isdn BRI terminals to the DSL Procedure Connecting the Isdn BRI terminals to the DSL Connecting the terminating resistorsConnect the Isdn BRI terminal to the S/T interface Installing Isdn BRI hardware for trunk applications Procedure Providing clock referencing on the Silc Removing the module cover for card installationInstalling the Misp Installing the clock reference on the SilcIsdn BRI clock reference tables Code Length feet Use Connecting clock reference cablesClock recovery Procedure Connecting clock reference cablesClock reference cable connection Installing the Silc and the Uilc Connecting the system to the Main Distribution Frame MDFCross-connecting the Main Distribution Frame MDF Installing Isdn BRI hardware for trunk applications SILC/UILC or Brsc Number Slot number Connector Ports Card location formsSILC/UILC or Brsc Installing Isdn BRI hardware for trunk applications Installing Isdn BRI hardware Verifying Isdn BRI operation IntroductionSetting up Isdn BRI test terminals and trunks Set up Isdn BRI terminalsProcedure Performing acceptance testing Isdn BRI acceptance testing setup for terminals Set up Isdn BRI trunking Local Exchange connectivitySet up Isdn BRI trunking TIE trunk connectivity Setting up Isdn BRI test terminals and trunks Preparing the system Line and packet data applications Hardware requirementsHardware Product code Description Isdn BRI trunkingNTAK20AB Cabinet Systems Installation proceduresSummary Correct responses to Loop and Misp prompts in LDInstallation procedures Silc is not Silc is cloc See Note Clock reference Reference Installation proceduresRemove the cover from the system 60 Configuring Isdn BRI hardware Remove the cover from the assigned system Procedure Installing the SILCs and UILCsSilc line power options Jumper plug settings for normal power on the TX and RX leads Procedure Installing the PRI hardware Procedure Removing the Silc and UilcConnecting the Isdn BRI terminals for line applications 66 Configuring Isdn BRI hardware End 68 Configuring Isdn BRI hardware Installation procedures Uilc port designation label at the cross-connect terminal TX+ BL-W BK-G TX+ BK-BR Cross-connecting a Silc port to the office wiring 74 Configuring Isdn BRI hardware Pin signal name Signal name Interface connector specification RJ45 jack76 Configuring Isdn BRI hardware End Connecting the Isdn BRI terminal to the S/T interface Connecting the Isdn network terminator to the U interface Procedure Initializing a Nortel Networks M5317TDX terminal No valid voice Spid M5317TDX terminal error codes Error Code Number DescriptionError Code Number Description Connecting the Isdn BRI trunks for trunking applicationsEnd Cross-connecting an Silc port Cross-connecting a Uilc port 86 Configuring Isdn BRI hardware Testing Isdn BRI functions Procedure Performing a call hold test Voice callsCall Hold Call Waiting Procedure Perform a Call Waiting testCall Forward No Answer Feature Fundamentals NN43001-580Calling Line Identification Presentation and Restriction Procedure Performing a Call Forward No Answer testIsdn BRI Conference National ISDN-1 and Etsi Procedure Perform an Isdn BRI Conference test Procedure Perform a Call Join test on Conference Isdn BRI Special Hunting Procedure Perform a hunting test Isdn BRI National ISDN-1 Call Forward All Calls Isdn BRI Etsi Call Forwarding Unconditional Procedure Perform a circuit-switched data call test Circuit-switched data callsPacket data transmission Packet data transmission End Testing an Isdn BRI trunk Removing the test setupProcedure Perform procedure to test an Isdn BRI trunk DSL Testing Isdn BRI functions Option Meaning Network traffic report Generating traffic reportsNetwork traffic report Page Isdn Basic Rate Interface Installation and Commissioning