American Power Conversion MX28B600 Display Type, 000255, Date, JUN 27, Time, 90025, Sys HV Thr

Page 29

MX28B600-48V

(Table 6.5-1. Parameter Locations, Descriptions, and Default Values)

PARAMETER

DESCRIPTION

DISPLAY SCREENS /

 

 

DEFAULT SETTINGS

Display Type

Type number for the control unit display.

Display Type

+

[SYSTEM/SETUP]

 

000255

 

 

 

 

Date/Time Setup

 

 

 

 

 

 

 

Date {1}

Internal system calendar date.

Date

m+

[SYSTEM/DATE]

 

JUN 27 2001

 

 

 

 

Time {1}

Internal system clock time (24-hour format).

Time

m+

[SYSTEM/DATE]

 

9:00:25

 

 

 

 

Alarm Threshold Setup

 

 

 

 

 

 

 

High Voltage Threshold {1}

System High voltage alarm threshold.

Sys HV Thr

m+

[SYSTEM/SET-ALM]

 

-58.00 V

 

 

Low Voltage Threshold {1}

System Low voltage alarm threshold.

Sys LV Thr

m+

[SYSTEM/SET-ALM]

 

-50.00 V

 

 

High Temperature Threshold {1}

Over temperature alarm threshold.

Sys HT Thr

m+

[SYSTEM/SET-ALM]

 

70.0 C

 

 

Low Temperature Threshold {1}

Under temperature alarm threshold.

Sys LT Thr

m+

[SYSTEM/SET-ALM]

 

0.0 C

 

 

System Status

 

 

 

 

 

 

 

System Voltage

System output voltage measured between the MX28B DC

Sys Voltage

+

[STATUS]

power plant -48V and return buses.

-54.00

V

 

 

System Current

The total system output current (calculated as the sum of the

Sys Current

+

[STATUS]

individual rectifier output currents).

445.8 A

 

 

System Temperature

System temperature measured within the control unit.

Sys Temp

+

[STATUS]

 

26.7 C

 

 

Battery Current

Battery current measured at the current shunt. Will display

Batt Current

+

[STATUS]

negative current when Batt is charging, Positive current

 

when Batt is discharging.

-15.0 A

Battery Temperature

Battery temperature measured by the optional battery

Batt Temp

+

[STATUS]

temperature sensor probe. NOTE: Will read about –156° C

 

with no probe attached

25.2 C

System Alarms

 

 

 

 

 

 

 

System High Voltage {1}

System voltage is above the high voltage threshold.

Sys HV Alm

m+

[SYSTEM/SET-ALM]

 

Minor

 

 

 

 

System Low Voltage {1}

System voltage is below the low-voltage threshold.

Sys LV Alm

m+

[SYSTEM/SET-ALM]

 

Minor

 

 

 

 

System High Temperature {1}

The control unit temperature is above the high temperature

Sys HT Alm

m+

[SYSTEM/SET-ALM]

threshold.

Minor

 

 

 

 

 

 

25

 

Image 29
Contents MX28B600 Revision History Product Overview and Technical Description Table of ContentsMX28B600 Introduction General InformationInspection upon Receipt of Goods General Visible External DamageConcealed Damage Customer Service and Support Warranty Returns Warranty ProvisionsWarranty Repair or Replacement General ProvisionsMX28B600 Description 1. MX28B6002. MX28B600 Block Diagram Control Unit Power Output CapacityRectifiers Battery connections AC Input PowerEnvironmental DC DistributionMounting Compliance MechanicalPreparation Recommended Tools Installation ProceduresRecommended Test Equipment Equipment InspectionVentilation Battery ConnectionsCable Sizing Considerations Connecting the CablesAlarm Connections 2. External Alarm Input Connections 1. External Alarm Input DefinitionAlarm Terminal Output Designation User Alarm Notes NO-NC-C Alarm Outputs2. GMT Fuses 1. Plug-in Circuit BreakersReattach the circuit breaker cover panel Load Connections Circuit Breakers Battery Temperature Probe InstallationPower-Up and Checkout Full System Power Up Apply AC PowerSystem Parameters Verification/Adjustment MX28B600-48V Snmp interface SETUP, ADJUSTMENTS, and OperationUser Interface Parameter Locations, Descriptions, and Default Values Alarm Output Relays1111 00002222 OEM R Offset000255 Display TypeDate JUN 27Test Min Rly Test RelayTest Maj Rly Batt FloatBatt HV Alm Batt Disc Alm m+Batt LV Alm Batt HT AlmRect RFA Alm Rect FF AlmCir Bkr 48VFuse 16 Alm Fuse 1 AlmIn-Rly Input RelayLVD2 Reset LVD1 ResetEnable Relay MajorMX28B600-48V 1. Control Unit Menu Structure 1. Control Unit Menu Structure Modules Rect SET-ALM Alias Fuse LVD SET-ALM

MX28B600 specifications

The American Power Conversion (APC) MX28B600 is a top-of-the-line uninterruptible power supply (UPS) designed to provide reliable power protection for a variety of applications. Known for its robust features and advanced technologies, the MX28B600 is an ideal solution for small to medium-sized data centers, telecommunications systems, and other critical IT infrastructure.

One of the standout features of the MX28B600 is its high capacity, which allows it to support a wide range of devices while accommodating future growth. With a power rating of 28 kVA, it can effectively handle multiple servers and network equipment without compromising performance. This capacity ensures business continuity even during power outages, surges, or fluctuations.

The MX28B600 utilizes advanced Double Conversion Online technology, which provides consistent and clean power to connected equipment. This technology ensures that the output voltage is tightly regulated, protecting sensitive electronics from damage and improving overall reliability. Additionally, the UPS features a wide input voltage range, allowing it to function effectively even in unstable power environments.

Another critical characteristic of the MX28B600 is its modular design, which provides flexibility for customization and scalability. Users can easily add or remove modules based on their evolving power requirements, making it a cost-effective solution over time. This modularity also simplifies maintenance and reduces downtime, ensuring that businesses can remain operational without interruptions.

The APC MX28B600 incorporates a user-friendly interface that makes monitoring and managing power needs straightforward. Its LCD display provides real-time information on battery status, output power, and alerts, allowing users to make informed decisions quickly. Additionally, the UPS is equipped with Remote Manager capabilities, enabling remote monitoring and management from any location, which is especially beneficial for IT administrators responsible for multiple sites.

Designed with energy efficiency in mind, the MX28B600 meets stringent environmental standards. Its Eco mode and Intelligent Battery Management system optimize battery life, reduce energy costs, and lower carbon emissions, contributing to a more sustainable operation.

In conclusion, the APC MX28B600 is an exceptional choice for businesses looking for reliable and efficient power protection. With its high capacity, advanced technologies, modular design, and energy-efficient operation, it is poised to meet the demands of modern organizations while ensuring continuous uptime and protecting critical equipment.