American Power Conversion MX28B600 manual Concealed Damage

Page 6

MX28B600

1)Make a descriptive notation on the delivery receipt before signing.

2)File a damage or shortage report with the carrier that delivered the shipment.

1.3.3Concealed Damage

It is the customer’s responsibility to unpack the power system and equipment received from APC and check for concealed damage, within 15 days of receipt of any and all materials. The customer is responsible to check the materials received against the detailed packing list to verify that the quantity and condition are complete and satisfactory.

Again, note any damage to the internal packing material, the equipment itself, and/or material or equipment shortages. If damage or shortage is noted, then:

1)Immediately request an inspection by the carrier;

2)File a concealed damage claim; and/or

3)File a material shortage claim with your APC representative.

DELAY IN NOTIFYING THE CARRIER MAY RESULT IN LOSS OF RIGHT TO REIMBURSEMENT FOR DAMAGES OR LOSS.

If you are unsure about the appearance of a part while conducting the materials inventory and inspection, refer to the manual or contact the Customer Service Department of APC.

Should you have any questions concerning potential damages or should you experience a lack of cooperation from your carrier, please contact your APC representative, or call APC.

1.3.4 Return of Damaged Goods

Should equipment be damaged and require return to APC for repair, the APC service representative will provide instructions along with a valid returned material authorization (RMA) number to facilitate return of the damaged goods to the APC repair center.

It is important that the steps outlined in Section 1.3.2 and Section 1.3.3 above are followed carefully. Your APC representative will assist you, if required, in obtaining proper disposition of an initial delivery return issue; however, a valid RMA number must be obtained before returning any equipment to APC.

- 2 -

Image 6
Contents MX28B600 Revision History Table of Contents Product Overview and Technical DescriptionMX28B600 Inspection upon Receipt of Goods General General InformationIntroduction Visible External DamageConcealed Damage Customer Service and Support Warranty Repair or Replacement Warranty ProvisionsWarranty Returns General ProvisionsMX28B600 1. MX28B600 Description2. MX28B600 Block Diagram Power Output Capacity RectifiersControl Unit AC Input Power Battery connectionsDC Distribution MountingEnvironmental Mechanical ComplianceRecommended Test Equipment Installation ProceduresPreparation Recommended Tools Equipment InspectionBattery Connections VentilationConnecting the Cables Alarm ConnectionsCable Sizing Considerations 1. External Alarm Input Definition 2. External Alarm Input ConnectionsAlarm Outputs Alarm Terminal Output Designation User Alarm Notes NO-NC-C1. Plug-in Circuit Breakers 2. GMT FusesReattach the circuit breaker cover panel Battery Temperature Probe Installation Power-Up and CheckoutLoad Connections Circuit Breakers Apply AC Power System Parameters Verification/AdjustmentFull System Power Up MX28B600-48V SETUP, ADJUSTMENTS, and Operation User InterfaceSnmp interface Alarm Output Relays Parameter Locations, Descriptions, and Default Values2222 00001111 OEM R OffsetDate Display Type000255 JUN 27Test Maj Rly Test RelayTest Min Rly Batt FloatBatt LV Alm Batt Disc Alm m+Batt HV Alm Batt HT AlmCir Bkr Rect FF AlmRect RFA Alm 48VIn-Rly Fuse 1 AlmFuse 16 Alm Input RelayEnable LVD1 ResetLVD2 Reset Relay MajorMX28B600-48V 1. Control Unit Menu Structure 1. Control Unit Menu Structure Modules Rect SET-ALM Alias Fuse LVD SET-ALM

MX28B600 specifications

The American Power Conversion (APC) MX28B600 is a top-of-the-line uninterruptible power supply (UPS) designed to provide reliable power protection for a variety of applications. Known for its robust features and advanced technologies, the MX28B600 is an ideal solution for small to medium-sized data centers, telecommunications systems, and other critical IT infrastructure.

One of the standout features of the MX28B600 is its high capacity, which allows it to support a wide range of devices while accommodating future growth. With a power rating of 28 kVA, it can effectively handle multiple servers and network equipment without compromising performance. This capacity ensures business continuity even during power outages, surges, or fluctuations.

The MX28B600 utilizes advanced Double Conversion Online technology, which provides consistent and clean power to connected equipment. This technology ensures that the output voltage is tightly regulated, protecting sensitive electronics from damage and improving overall reliability. Additionally, the UPS features a wide input voltage range, allowing it to function effectively even in unstable power environments.

Another critical characteristic of the MX28B600 is its modular design, which provides flexibility for customization and scalability. Users can easily add or remove modules based on their evolving power requirements, making it a cost-effective solution over time. This modularity also simplifies maintenance and reduces downtime, ensuring that businesses can remain operational without interruptions.

The APC MX28B600 incorporates a user-friendly interface that makes monitoring and managing power needs straightforward. Its LCD display provides real-time information on battery status, output power, and alerts, allowing users to make informed decisions quickly. Additionally, the UPS is equipped with Remote Manager capabilities, enabling remote monitoring and management from any location, which is especially beneficial for IT administrators responsible for multiple sites.

Designed with energy efficiency in mind, the MX28B600 meets stringent environmental standards. Its Eco mode and Intelligent Battery Management system optimize battery life, reduce energy costs, and lower carbon emissions, contributing to a more sustainable operation.

In conclusion, the APC MX28B600 is an exceptional choice for businesses looking for reliable and efficient power protection. With its high capacity, advanced technologies, modular design, and energy-efficient operation, it is poised to meet the demands of modern organizations while ensuring continuous uptime and protecting critical equipment.