Section 1. Unpacking/Inspection (at reseller location)

Main Housing Chassis and Inverter

!Warning: The Main Housing Chassis weighs 18 kg. Two-person lift required. Failure to comply may result in personal injury.

Inspect the shipping containers for signs of obvious damage. If damage to either shipping container is extensive, notify the carrier and return the unit to the factory. If there are no apparent signs of damage, carefully open the container, and remove the packing materials (do not discard). To remove the Main Housing Chassis or Inverter Assembly from the shipping container, grasp the handles located on each side of the housing or inverter (Figure 1), and remove the item from the container. Inspect each for: dents, scratches, broken or missing wheels (housing only), warpage of the top cover, or other signs of damage. If either unit is damaged, please notify the factory and obtain a Return Material Authorization number and return the unit as/if instructed. If there are no obvious signs of damage, repackage the unit for shipment to the customer using the materials already removed from the shipping container. Ship or otherwise deliver the unit to the customer location.

Battery Inspection

Unpack Battery - Inspect the battery shipping container for signs of obvious damage. Carefully inspect the container for signs of a leaking battery. If the shipping container shows signs of leakage, the battery may be damaged. Contact the factory for instructions to further inspect the battery inside the container, or for return instructions. Carefully open the shipping container and remove the packing materials (do not discard).

Inspect Battery - If there are no obvious signs of damage or leakage, with the battery in the shipping container, inspect the battery for leaks, cracks, broken wiring terminals, broken handles, and broken fill caps (Figure 2).

Battery Handle

(1 each side)

Battery Fill Cap (6)

Battery Terminal (2)

Figure 2. Battery Elements (tubular battery shown)

Clean battery - If the inspection shows signs of a leaking battery, put on rubber gloves and remove the battery fluid/residue from the battery housing using a mixture of baking soda and distilled water. If cracks or other damage is noted after cleaning the battery, contact the factory for return or disposal instructions.

!Warning: Each battery weighs 28 kg. Two-person lift required. Failure to comply may result in personal injury.

Remove Battery from Shipping Container - Remove the battery from the shipping container by grasping the handles (see Figure 1) located at each end of the battery. Lift the battery straight up and out of the shipping container.

Check Battery Fluid Level - After cleaning and inspection for damage, check the battery fluid level of each cell (Figure 3). If the fluid level of any cell is not within the specified range on the fill cap, put on rubber gloves (from Fill Kit), remove the battery cell cap, and fill the cell with distilled water using the funnel provided in the Fill Kit. Install the cell cap on each cell.

Page 2

Image 5
Contents Power Inverter Contents Contents Overview Battery Handle Fluid Level Installation Main Housing Placement Do Not Remove These Two Screws Battery Installation Inverter Assembly Placement Electricity Load Board Kit Alignment Pins Holes 4 places Power Inverter Indicators Battery Power Inverter Troubleshooting Push to Reset Input 5A, 50Hz Output Specifications 15/Page 16 blank