American Power Conversion RT user manual Introduction, Unpacking, Specifications

Page 3

Introduction

The APC Smart-UPS® RT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment from utility power blackouts, brownouts, sags and surges. The UPS filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power. The UPS provides continuous power from the internal battery until utility power returns to safe levels or the battery is fully discharged.

INSTALLATION

Read the Safety Guide before installing the UPS.

Unpacking

Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly.

Check the package contents:

„UPS (with battery modules disconnected)

„Front bezel

„Literature kit containing:

„Product documentation, Safety Guide, and Warranty Information

„Smart-UPS RT User Manuals CD

„Software CD

„Serial cable

„3000 VA XLI models: three output power cords, two input power cords

„5000/6000 VA XLI models: six output power cords, Network Management Card documentation

Specifications

TEMPERATURE

 

This unit is designed for indoor use

OPERATING

32° to 104° F (0° to 40° C)

only. Select a location sturdy enough to

STORAGE

5° to 113° F (-15° to 45° C) charge the UPS

handle the weight.

 

battery every six months

Do not operate the UPS where there is

MAXIMUM

 

excessive dust or the temperature and

ELEVATION

 

humidity are outside the specified limits.

OPERATING

10,000 ft (3,000 m)

Ensure that the air vents on the front

STORAGE

50,000 ft (15,240 m)

and rear of the UPS are not blocked.

 

 

 

 

 

HUMIDITY

0 to 95% relative humidity

 

 

 

 

 

 

 

 

WEIGHT

 

 

 

 

UPS

120 lbs (55 kg)

 

 

 

UPS WITH

140 lbs (64 kg)

 

 

 

PACKAGING

 

 

 

 

1

Image 3
Contents APC Smart-UPSRT Page Specifications IntroductionUnpacking Wiring and Connecting the UPS Connecting the Battery Modules and Attaching the Front Bezel Normal bypass Avoid using extension cords Operation Does not affect the voltage display On Battery OperationUser Configurable Items XLJ models VA models 5000/6000 VA models Replacing the Battery Module Disconnecting the Battery for Transport TROUBLESHOOTING, SERVICE, and Warranty Information Bypass LED Illuminates Limited Warranty Service200, 208, 220, 230, 240 V Models Regulatory Agency Approvals and Radio Frequency WarningsDeclaration of Conformity APC Worldwide Customer Support