Thank you for choosing the APC BC300 Series. Read this Installation Guide before you install and use the system as it provides important information on safe and efficient installation and use.

The installation and use of this product must comply with national, federal, state, municipal and local codes.

IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS

Safety Symbols used in this manual

WARNING! Indicates a hazard which, if not avoided, could result in injury or death.

CAUTION! Indicates a hazard which, if not avoided, could result in damage to the product or other property.

NOTICE! Read and pay attention to this important information.

WARNING

This UPS unit contains hazardous AC and DC voltages. Only qualified electricians should connect the UPS, AC line and external batteries, and must be familiar with batteries and battery installation.

Before installing, maintaining or servicing the UPS, shut off the UPS and disconnect all sources of AC and DC power.

As the UPS has no built-in disconnection devices to switch off external AC and DC input power, ensure that disconnection devices are available as separate parts in connection with the installation.

The installer must provide each external disconnecting device for this UPS system with labels with the following text:

“Isolate the Uninterruptible Power Supply (UPS) as instructed in this guide before working on circuit”.

AC and/or DC voltage will always involve a potential risk of AC voltage at UPS output generated from either batteries or utility. To avoid equipment damage or personal injury, always assume that there may be voltage at UPS output.

This system is equipped with an auto-start function. If activated, the system may start without warning. Refer to the “Programming” section for information on de-activation.

TEST BEFORE YOU TOUCH!

To reduce the risk of fire or electric shocks, install the UPS and external batteries in a temperature and humidity controlled indoor area, free of conductive contaminants.

UPS batteries are high-current sources. Shorting battery terminals, DC terminals or DC busbars can cause severe arcing, equipment damage and injury. A short circuit can cause a battery to explode. Always wear protective clothing and eye protection and use insulated tools when working on batteries.

CAUTION!

This unit contains components sensitive to electrostatic discharge (ESD). If you do not follow the ESD procedures, you may cause severe damage to electronic components.

990-1378

2

Installation Guide APC BC300 Series 10kW 208/450/480V UPS

Image 2
Contents APC BC300 Series 10kW 208/450/480V Installation Guide Copyright 2002 APC Denmark ApSThank You Installation Guide APC BC300 Series 10kW 208/450/480V UPSSafety Symbols used in this manual Contents Tools and Equipment Needed IntroductionIntroduction Insulated Tools and Other Equipment NeededReceiving, Unpacking and Moving to Site Please RecycleRequirements on Site InstallationInstallation Insulated and other tools required Installing the Conduit Connection KitUPS Footprint measurements in inches & mm Installing Conduit Box and Base Covers Conduit Connection Kit ContentsInstalling Pedestals Installing the Maintenance Bypass Panel and UPS SBP Electrical Schematic 208V SBP Electrical Schematic SBP Electromechanical 10kW 208V SBP Electromechanical 10kW Component Overview door open Component OverviewWire Terminals Wire TerminalsWiring Diagram for BC300 Utility inputSingle Line Diagram for BC300 Single Line Diagram for BC300Wiring Line Diagram for BC300 25A.T UPS Model Input Output Recom DC Voltage DC Current Mended MIBExternal Connection Board External Connection BoardCommunication Interface Board Option Communication Interface BoardSmart Slot and Connection of Triple Chassis Communication InterfaceProduct Description Safety WarningsAPC BC300 Triple Chassis Monitoring PortInstalling Management Cards Power InputInstalling Management Products To UPS PortPower Considerations Cascading setup of the APC BC300 Triple ChassisPowering the APC BC300 Triple Chassis Power AdaptersTroubleshooting Triple Chassis Power ConsiderationsDetermining Power Requirements Problem Possible Cause SolutionProduct Specifications Monitoring Port Pin Assignments Monitoring Port Pin Assignment Battery Installation Installation of External Batteries and Battery BreakerPower, Physical, and Environmental Specifications PhysicalBattery Installation Guidelines Do not connect the negative cables to the UPS yet Battery Replacement Initial Start-up and Phase Check Internal Batteries Initial Start-up and Phase CheckInitial Start-up and Phase Check Initial Start-up and Phase Check External Batteries DC FusesInitial Start-up and Phase Check Clearing the Events Log Clearing the Events LogStart-up from Maintenance Bypass Start-up and Shutdown ProcedureStart-up and Shutdown Procedure Shutdown Procedure If you have shut the loads down Move on to stepAPC BC300 Series 10kW Technical Data Technical SpecificationsTechnical Specifications Battery Specifications GeneralDimensions/Weight BC300 Series UPS 10kWAPC Corporate How to Contact APCHow to Contact APC Fairgrounds Road West Kingston, RIHow to Contact APC

990-1378 specifications

The APC 990-1378 is a high-performance power supply designed for environments where reliability and efficiency are paramount. As a part of APC's range of power protection solutions, this unit is specifically engineered to safeguard critical electronic devices and maintain consistent power delivery even under demanding conditions.

One of the main features of the APC 990-1378 is its robust battery backup system. This ensures that connected devices remain operational during power outages, providing peace of mind for businesses and individuals relying on constant power supply for applications such as networking, telecommunications, and computer systems. The unit is equipped with advanced battery management technology that extends battery life while optimizing energy consumption.

In terms of technologies, the APC 990-1378 incorporates sine wave output, which delivers clean and stable power suitable for sensitive electronic equipment. This feature is essential for preventing equipment damage caused by power surges or fluctuations. Moreover, the power supply comes with multiple outlets, allowing users to connect several devices simultaneously without compromising performance.

Another characteristic that sets the APC 990-1378 apart is its intelligent LCD display. This user-friendly interface provides real-time information on power consumption, battery status, and system health, allowing users to monitor performance easily. The display also features customizable settings, giving users the flexibility to adapt the unit to their specific needs.

The build quality of the APC 990-1378 is impressive, designed to endure both indoor and outdoor environments. Its rugged casing and efficient cooling system guarantee reliable operation in various conditions, making it suitable for different applications, from home offices to enterprise data centers. Additionally, the compact design of this power supply saves valuable space, an essential consideration for users with limited installation areas.

The APC 990-1378 is also compatible with various management software solutions that facilitate remote monitoring and control. This capability is particularly beneficial for IT administrators who need to manage multiple units across different locations efficiently.

In summary, the APC 990-1378 is a versatile and reliable power supply that prioritizes performance, safety, and user convenience. Its advanced features and technologies make it a valuable asset for anyone seeking reliable power protection solutions in today's increasingly tech-driven world.