APC 990-1378 manual Product Specifications Monitoring Port Pin Assignments

Page 28

Installation

1)Note the serial number and date of purchase of the APC BC300 Triple Chassis. Contact APC Customer Support at the phone number or address listed in How to Contact APC section of this manual.

2)Be prepared to provide a description of the problem. A technician will help solve the problem over the phone, if possible, or will give you a return material authorization (RMA) number.

3)If the APC BC300 Triple Chassis is under warranty, repairs are free of charge. If the warranty has expired, there will be a nominal charge for repair.

4)Pack the APC BC300 Triple Chassis carefully in its original packaging, if possible. Do not use polystyrene beads for packing. Damage sustained in transit is not covered under the warranty. Enclose a letter in the package with your name, address, RMA number, a copy of the sales receipt, daytime phone number, and payment (if applicable).

5)Mark the RMA number clearly on the outside of the shipping carton. The factory will not accept any materials without this marking.

6)Return the Triple Chassis by insured, prepaid carrier to the address given to you by APC Customer Support.

3.5.6 Product Specifications

3.5.6.1 Monitoring Port Pin Assignments

The Monitoring port is a 9-pin communications port. The port operates with no flow control at a rate of 2400 baud. The data format is 8 data bits with 1 start bit, 1 stop bit, and no parity. When the Triple Chassis operates with simple signalling, the following limitations and capabilities apply to the Monitoring port:

Pins 3, 5, and 6 are open collector outputs which must be pulled up to a common referenced supply no greater than +40 VDC. The transistors are capable of a non- inductive load of 25 mA. Use only Pin 4 as the common.

The output at Pin 2 generates a low-to-high RS-232 level when the device is signalling an On Battery condition. The pin is normally at a low RS-232 level.

The UPS is signalled to shut down when a high RS-232 level is applied to Pin 1 for 4.5 seconds. Shutdown is also dependent on the UPS status.

When the Triple Chassis operates with advanced signaling, the following limitations and capabilities apply to the Monitoring port:

Pin 7 is unassigned.

DC operating voltage is available on Pin 8. This voltage may be from the UPS or from an external adapter.

990-1378

28

Installation Guide APC BC300 Series 10kW 208/450/480V UPS

Image 28
Contents APC BC300 Series 10kW 208/450/480V Installation Guide Copyright 2002 APC Denmark ApSSafety Symbols used in this manual Installation Guide APC BC300 Series 10kW 208/450/480V UPSThank You Contents Introduction IntroductionTools and Equipment Needed Insulated Tools and Other Equipment NeededReceiving, Unpacking and Moving to Site Please RecycleInstallation InstallationRequirements on Site UPS Footprint measurements in inches & mm Installing the Conduit Connection KitInsulated and other tools required Installing Pedestals Conduit Connection Kit ContentsInstalling Conduit Box and Base Covers Installing the Maintenance Bypass Panel and UPS SBP Electrical Schematic 208V SBP Electrical Schematic SBP Electromechanical 10kW 208V SBP Electromechanical 10kW Component Overview door open Component OverviewWire Terminals Wire TerminalsWiring Diagram for BC300 Utility inputSingle Line Diagram for BC300 Single Line Diagram for BC300Wiring Line Diagram for BC300 25A.T UPS Model Input Output Recom DC Voltage DC Current Mended MIBExternal Connection Board External Connection BoardCommunication Interface Board Option Communication Interface BoardSmart Slot and Connection of Triple Chassis Communication InterfaceSafety Warnings APC BC300 Triple ChassisProduct Description Monitoring PortPower Input Installing Management ProductsInstalling Management Cards To UPS PortCascading setup of the APC BC300 Triple Chassis Powering the APC BC300 Triple ChassisPower Considerations Power AdaptersTriple Chassis Power Considerations Determining Power RequirementsTroubleshooting Problem Possible Cause SolutionProduct Specifications Monitoring Port Pin Assignments Monitoring Port Pin Assignment Installation of External Batteries and Battery Breaker Power, Physical, and Environmental SpecificationsBattery Installation PhysicalBattery Installation Guidelines Do not connect the negative cables to the UPS yet Battery Replacement Initial Start-up and Phase Check Initial Start-up and Phase CheckInitial Start-up and Phase Check Internal Batteries Initial Start-up and Phase Check External Batteries DC FusesInitial Start-up and Phase Check Clearing the Events Log Clearing the Events LogStart-up and Shutdown Procedure Start-up and Shutdown ProcedureStart-up from Maintenance Bypass Shutdown Procedure If you have shut the loads down Move on to stepTechnical Specifications Technical SpecificationsAPC BC300 Series 10kW Technical Data Battery Specifications GeneralDimensions/Weight BC300 Series UPS 10kWHow to Contact APC How to Contact APCAPC Corporate Fairgrounds Road West Kingston, RIHow to Contact APC

990-1378 specifications

The APC 990-1378 is a high-performance power supply designed for environments where reliability and efficiency are paramount. As a part of APC's range of power protection solutions, this unit is specifically engineered to safeguard critical electronic devices and maintain consistent power delivery even under demanding conditions.

One of the main features of the APC 990-1378 is its robust battery backup system. This ensures that connected devices remain operational during power outages, providing peace of mind for businesses and individuals relying on constant power supply for applications such as networking, telecommunications, and computer systems. The unit is equipped with advanced battery management technology that extends battery life while optimizing energy consumption.

In terms of technologies, the APC 990-1378 incorporates sine wave output, which delivers clean and stable power suitable for sensitive electronic equipment. This feature is essential for preventing equipment damage caused by power surges or fluctuations. Moreover, the power supply comes with multiple outlets, allowing users to connect several devices simultaneously without compromising performance.

Another characteristic that sets the APC 990-1378 apart is its intelligent LCD display. This user-friendly interface provides real-time information on power consumption, battery status, and system health, allowing users to monitor performance easily. The display also features customizable settings, giving users the flexibility to adapt the unit to their specific needs.

The build quality of the APC 990-1378 is impressive, designed to endure both indoor and outdoor environments. Its rugged casing and efficient cooling system guarantee reliable operation in various conditions, making it suitable for different applications, from home offices to enterprise data centers. Additionally, the compact design of this power supply saves valuable space, an essential consideration for users with limited installation areas.

The APC 990-1378 is also compatible with various management software solutions that facilitate remote monitoring and control. This capability is particularly beneficial for IT administrators who need to manage multiple units across different locations efficiently.

In summary, the APC 990-1378 is a versatile and reliable power supply that prioritizes performance, safety, and user convenience. Its advanced features and technologies make it a valuable asset for anyone seeking reliable power protection solutions in today's increasingly tech-driven world.