APC 5000T, 3000T, 2200XLT, 1400XLT user manual Table of Contents

Page 5

Table of Contents

 

Introduction

1

Unpacking

1

Installation

1

Initial Startup

7

Operating Instructions

8

Storage

11

Replacing the Battery

11

User Configuration Items

16

How to Determine On-Battery Run Time

16

Specifications

19

Troubleshooting

20

Service

21

APC Contact Information

21

Limited Warranty

21

Appendix A: XL Information

23

XL Installation

23

Smart-UPS Battery Protocol

23

Appendix B: Types of Racks and Mounting Hardware

26

Racks

26

Appendix C: Transporting Your Smart-UPS

27

990-7031D, Revision 5 5/01

Image 5
Contents 990-7031D, Revision 5 5/01 990-7031D, Revision 5 5/01 Replacement and Recycling of Batteries Handling SafetyElectrical Safety 990-7031D, Revision 5 5/01 Table of Contents Page Unpacking InstallationIntroduction Installing Rack Mount Units PlacementFront Rack Mount Options Load the UPS into the RackTower Units Connect the Batteries5U Rack Mount Units 3U Rack Mount UnitsRear Views Charge the batteryInitial Startup Operating Instructions Battery Charge Bar Graph On BatteryShutdown Mode Replace BatterySmartBoost Low BatteryCold Start Cold start is not a normal conditionStorage Replacing the BatteryStorage Conditions Extended storageBattery Replacement Procedure Tower Units Battery Replacement Procedure 3U Rack Mount Units Battery Replacement Procedure 5U Rack Mount Units 990-7031D, Revision 5 5/01 How to Determine On-Battery Run Time User Configuration ItemsTypical On-Battery Runtime Versus Load, in Hours Tower and 5U Models 1400VA and 2200VA Models2200 3U Rack Mount Models 2200 & 3000 VA Models Tower and 5U Rack Mount Models 3000 & 5000 VA Models1400 VA 2200 VA 3000 VA 5000 VA SpecificationsTroubleshooting Limited Warranty ServiceIf the UPS requires service do not return it to the dealer APC Contact Information990-7031D, Revision 5 5/01 Smart-UPS Battery Protocol XL InstallationClick on Configuration Click on UPS Operating Parameters Use the Smart-UPS Battery Pack Utility BattpackStep Number Type Produced Effect Rack Type Hole Type Hardware Required Hardware Included RacksAppendix C Transporting Your Smart-UPS
Related manuals
Manual 40 pages 63.83 Kb

3000T, 1400XLT, 5000T, 2200XLT specifications

The APC (American Power Conversion) range of Uninterruptible Power Supplies (UPS) includes models such as the 2200XLT, 5000T, 1400XLT, and 3000T, each designed to meet different power protection needs in various environments. These models provide reliable backup power and surge protection, ensuring that electronic devices remain operational during utility power disruptions.

The APC 2200XLT is known for its robust performance and efficiency. This model features on-line double conversion technology, which guarantees that connected equipment receives pure sine wave power, crucial for sensitive electronics. With a power capacity of 2200 VA, the 2200XLT accommodates high-energy requirements, making it ideal for small to medium-sized businesses. The LCD display provides real-time status on power conditions, battery health, and load levels, ensuring users are always informed.

The APC 5000T, with a power capacity of 5000 VA, is designed for larger operations, providing substantial backup power for critical infrastructure. This model offers advanced features such as hot-swappable batteries, allowing maintenance without disrupting power to connected devices. The 5000T also includes PowerChute software, facilitating monitoring and management of UPS systems via a user-friendly interface. Its enhanced scalability means it can easily be expanded to meet growing power needs.

The APC 1400XLT is compact yet efficient, offering 1400 VA of power. It excels in providing reliable protection for desktop computers and workstations. Featuring Power Factor Correction (PFC), this model optimizes power delivery, resulting in increased energy savings. Its customizable alarm settings and easy-to-read LCD panel make it user-friendly, ensuring that even those with minimal technical expertise can operate it effectively.

Lastly, the APC 3000T serves as a versatile powerhouse for small to medium-sized data centers. Its 3000 VA capacity supports critical equipment, while redundant features enhance reliability. The unit is also equipped with a network management card for remote monitoring capabilities. The 3000T's ability to configure and manage multiple units in a parallel setup allows businesses to ensure that their power needs are met while maximizing uptime.

In summary, the APC 2200XLT, 5000T, 1400XLT, and 3000T UPS models offer a variety of features and technologies designed to ensure power availability and system reliability across various applications. These units emphasize security against power disturbances while providing a solid return on investment for organizations seeking to protect their critical electronic infrastructure.