Agilent Technologies 6015A, 6010a, 6011A, 6012B service manual Not Used

Page 71

Table 5-3. Replaceable Parts List (continued)

Ref. Desig.

Agilent Model

Agilent Part Number

Description

R58

6010A

0698-0533

fxd film 4.64K 0.1% 1/8W

R58

6011A

0698-6392

fxd film 22K 0.1% 1/8W

R58

6012B, 6015A

0699-1212

fxd film 19K 0.1% 1/8W

R59

All

0683-6215

fxd film 620 52 1/4W

R60-62

All

0683-2015

fxd film 200 5% 1/4W

R63

All

0683-5125

fxd film 5.1K 5% 1/4W

R64

All

0683-1025

fxd film 1K 5% 1/4W

R65,66

6010A, 6011A, 6012B

0683-5615

fxd film 560 5% 1/4W

R65,66

6015A

0683-3201

fxd film 560 5% 1/4W

R67

6010A, 6011A

0757-0449

fxd film 20K 1% 1/8W

R67

6012B

0757-0453

fxd film 30.1K 1% 1/8W

R67

6015A

0757-5615

fxd film 20K 1% 1/8W

R68

6010A, 6011A, 6015A

0698-3201

fxd film 80K 1% 1/8W

R68

6012B

0757-0449

fxd film 20K 1% 1/8W

R69

6010A, 6011A, 6015A

0757-0442

fxd film 10K 1% 1/8W

R70

6010A, 6011A

0698-7353

fxd film 19K 1% 1/8W

R70

6012B

0698-4493

fxd film 34K 1% 1/8W

R70

6015A

0698-6671

fxd film 7K 0.25% 1/8W

R71

6010A, 6011A, 6015A

0757-0280

fxd film 1K 1% 1/8W

R71

6012B

0698-3476

fxd film 6K 1% 1/8W

R72

All

0698-6362

fxd film 1K 0.1% 1/8W

R73

All

0757-0452

fxd film 27.4K 1% 1/8W

R74

All

NOT USED

 

R75

All

0683-5135

fxd film 51K 5% 1/4W

R76

All

0757-0441

fxd film 8.25K 1% 1/8W

R77

6010A, 6011A, 6012B

0698-3159

fxd film 26.lK 1% 1/8W

R77

6015A

NOT USED

 

R78

All

0757-0458

fxd film 51.1K 1% 1/8W

R79

All

0683-1025

fxd film 1K 5% 1/4W

R80

All

0683-5135

fxd film 51K 5% 1/4W

R81

All

0683-3025

fxd film 3K 5% 1/4W

R82

All

0683-1025

fxd film 1K 5% 1/4W

R83

6010A

0698-6363

fxd film 9K 0.1% 1/8W

R83

6011A, 6012B

0698-6343

fxd film 9K 0.1% 1/8W

R83

6015A

0698-6322

fxd film 4K 0.1%

R84

6010A

0698-6563

fxd film 40K 0.1% 1/8W

R84

6011A

0698-6363

fxd film 40K 0.1% 1/8W

R84

6012B

0698-8861

fxd film 6.66K 0.1% 1/8W

R84

6015A

0699-1211

fxd film 95K 0.1%

R85

All

0757-0438

fxd film 5.11K 1% 1/8W

R86

All

0683-5135

fxd film 51K 5% 1/4W

R87

All

0757-0199

fxd film 21.5K 1% 1/8W

R88

All

0683-3925

fxd film 3.9K 5% 1/4W

R89

All

0698-5808

fxd film 4K 1% 1/8W

R90

All

0686-6815

fxd comp 680 5% 1/2W

R91

All

0757-0452

fxd film 27.4K 1% 1/8W

R92

All

NOT USED

 

R93

All

0683-2025

fxd film 2K 5% 1/4W

R94

All

0757-0280

fxd film 1K 1% 1/8W

R95

All

0683-l035

fxd film 10K 5% 1/4W

R96

All

0683-5125

fxd film 5.1K 5% 1/4W

71

Image 71
Contents Autoranging DC Power Supply Agilent Models 6010A, 6011A Certification Safety Summary Safety Symbol Definitions Table of Contents Replaceable Parts Scope TroubleshootingCircuit Diagrams Safety ConsiderationsItem Description Manual RevisionsOperation Verification Tests Calibration ProcedureIntroduction Test Equipment RequiredTest Equipment Required Type Required Characteristics USE Recommended Model4KVA Calibration Procedure Initial SetupMON Iout Display SettingsVout Common Mode Setup CR4 Performance TestsMeasurement Techniques Current-Monitoring Resistor Setup Constant Voltage CV Tests Basic Test SetupPage RMS Measurement Test Setup, CV Pard Test Peak-To-Peak Measurement Test Setup, CV Pard Test 6012B 6015A 6010A 6011ANot Applicable 6010A 6011A 6012B 6015A Load Transient Recovery WaveformConstant Current CC Tests Page CC Pard Test Setup Initial Troubleshooting Procedures TroubleshootingVdc Control Board Test Connector, A2J7Electrostatic Protection Repair and ReplacementA4 FET Board Removal A2 Control Board RemovalA1 Main Board Removal A5 Diode Board RemovalA3 Front Panel Board Removal A3 Front Panel Assembly Rear View Overall Troubleshooting ProcedureA1 Designator Wire color A3S1 Position Rear View Main Troubleshooting Setup Using the TablesMain Troubleshooting Setup Modified Mains Cord Set For Troubleshooting Front Panel Troubleshooting Troubleshooting No-Output FailuresA2J7-26 A2J7-25 Performance Failure Symptoms Troubleshooting Bias SuppliesA3 Front Panel Board Failure Symptoms Node + N0DE Node +Troubleshooting AC-Turn-on Circuits Power Section Blocks+ OUT Troubleshooting PWM & ClockAC Fault Relay EnablePWM-OFF Troubleshooting DC-To-DC ConverterTroubleshooting Down Programmer PWM-ONWaveforms OFF Troubleshooting CV CircuitTroubleshooting CC Circuit ON/OFFSET Voltage Setup Measurement Troubleshooting OVP CircuitPage System Description Autoranging PowerOverview Regulation & Control Subsystem A and 6015A Simplified Schematic A and 6012B Simplified Schematic Input from Output to Quick Reference Guide to Major Circuits Major FunctionOperation DP PWM PWM DPProtection Subsystem Input Power SubsystemFront Panel Board DC Power Conversion SubsystemOutput Subsystem Page Simplified Front Panel Schematic Reference Designators Replaceable PartsDescription Abbreviations Ordering InformationMain Board Assembly CR5 CB1CR1 CR2A1 Mechanical VR16010A C37 6010A, 6011A, 6015A Not Used Not Used Not Used Page Not Used VR6 VR2VR5 TB2 TB1Not Used Agilent Model VR1 VR2Drvr TTL NOR Dual TS1FET N-CHAN CR3CR6 A5 Mechanical A6 Mechanical Chassis Electrical Not Used Schematic Diagram Notes Component Location and Circuit DiagramsIndicate number of paths represented by the line Top View, Top Covers Removed Main Board A1 and Filter Board A6 Component Location Control Board A2 Component Location Front Panel Board A3 Component Location FET Board A4 Component Location Diode Board A5 Component Location Page Page Page Page Option 002 Hardware SpecificationsGeneral Information Accuracy Table A-1. Specifications, Option Remote ProgrammingInput Compliance Voltage ± Current Programming Enable Status IndicatorsOn State logic low Remote Trip and Remote Reset TimingPower-on Preset Maximum Output Voltage logic high +Pard Typical Table A-1. Specifications, Option Pulse TimingBias Supplies DC Output Ratings 25C ± Short Circuit Output CurrentConnector Assembly Procedure InstallationOperation Figure A-1. Mating Connector AssemblyLocal/Remote Programming Resistance Voltage or Current Figure A-4. Calculating Value of Series Dropping Resistor Remote Resistance ProgrammingFigure A-5. Remote Resistance Programming 101 Remote Monitoring102 Status IndicatorsRemote Control 103 Remote ResetOvervoltage 104 Power-On Preset105 AC Dropout Buffer CircuitMultiple Supply System Shutdown 106 MaintenanceBias Supplies 107 Troubleshooting Resistance and Voltage ProgrammingTroubleshooting Current Programming 108 Figure A-11. Troubleshooting Current Programming of CV Mode109 Figure A-13. Troubleshooting Status Indicators110 111 Table A-3. Replacement Parts112 113 VR9114 Logic Symbols and DefinitionsIndicator and Qualifier Symbols 115 Schematic Diagram NotesFigure A-15. Option 002 Board, Component Location 116 Schematic NotesFigure A-16. Option 002 Board, Schematic Diagram 117 Page 119 Model 6010A ChangeModel 6011A Change 120 Model 6012B ChangeModel 6015A Change 121 Delete122 123 124 125 DS5126
Related manuals
Manual 48 pages 27.24 Kb

6015A, 6012B, 6011A, 6010a specifications

Agilent Technologies, a leader in the field of measurement and analysis, offers a suite of instruments within its 6010 and 6011 series, specifically the 6010A, 6011A, 6012B, and 6015A models. These devices are designed to meet the needs of various industries, including healthcare, environmental monitoring, and materials testing.

The Agilent 6010A is a high-performance spectrometer known for its precision and versatility. It utilizes advanced optical technologies to provide exceptional wavelength accuracy and resolution. This model is particularly useful in laboratories where reliable data is critical, offering a wide spectral range and effective noise reduction features. Its user-friendly interface simplifies complex analyses, making it suitable for both seasoned professionals and newcomers.

Following closely, the Agilent 6011A is recognized for its robust capabilities in laboratory environments. This device incorporates advanced signal processing techniques, enabling high-throughput measurements without compromising on quality. The 6011A is ideal for real-time monitoring applications, ensuring that users can make informed decisions based on accurate, timely data. Its comprehensive software suite is designed to enhance data analysis, allowing for seamless integration with existing laboratory workflows.

The 6012B variant enhances the functionality further by introducing additional features tailored for specific applications. With a focus on flexibility, the 6012B supports multiple measurement modes, including direct and differential detection. This model excels in complex measurements, allowing for greater analytical depth and insights. The built-in calibration options ensure consistent performance, making it a reliable choice for various research and development tasks.

Lastly, the Agilent 6015A model stands out with its leading-edge technology, designed for the most demanding applications. It boasts enhanced sensitivity and an improved dynamic range, making it perfect for trace analysis in challenging environmental samples. The 6015A’s advanced reporting tools provide detailed analytics, helping scientists and researchers interpret results efficiently. Its compact design also makes it suitable for laboratory spaces with limited room, without sacrificing performance.

Together, these models showcase Agilent Technologies' commitment to delivering high-quality, innovative solutions that empower users to achieve their analytical goals effectively and efficiently. Whether in a research, clinical, or industrial setting, the 6010A, 6011A, 6012B, and 6015A continue to set standards in precision instrumentation.