Agilent Technologies 6010a, 6011A, 6012B, 6015A service manual Not Used

Page 68

Table 5-3. Replaceable Parts List (continued)

Ref. Desig.

Agilent Model

Agilent Part Number

Description

R125

All

0757-0465

fxd film 100K 1% 1/8W

R126

All

0757-0442

fxd film 10K 1% 1/8W

R127

All

0698-8827

fxd film 1M 1% 1/8W

R128

All

0698-3136

fxd film 17.8k 1% 1/8W

R129

All

0698-4121

fxd film 11.3K 1% 1/8W

R130

6010A, 6015A

NOT USED

 

R131

All

0757-0449

fxd film 20K 1% 1/8W

R132

All

1810-0205

resistor network

R133

All

0683-5625

fxd film 5.6K 5% 1/4W

R134

All

0683-1025

fxd film 1K 5% 1/4W

R135

All

0683-1855

fxd film 1.8M 5% 1/4W

R136

All

0757-0420

fxd film 750 1% 1/4W

R137

All

0698-4435

fxd film 2.49K 1% 1/8W

R138

All

0757-0199

fxd film 21.5K 1% 1/8W

R139

All

0683-4725

fxd film 4.7K 5% 1/4W

R140

All

0683-2025

fxd film 2K 5% 1/4W

R141

All

0683-5135

fxd film 51K 5% 1/4W

R142

All

0683-6835

fxd film 68K 5% 1/4W

R143

All

0683-4725

fxd film 4.7K 52 1/4W

R144

All

0757-0415

fxd film 475 1% 1/8W

R145

All

0683-1005

fxd film 10 52 1/4W

R146

All

0683-1035

fxd film 10K 52 1/4W

R147

All

0683-5115

fxd film 510 5% 1/4W

R148

All

0757-0422

fxd film 909 1% 1/8W

R149

All

0683-2025

fxd film 2K 5% 1/4W

R150

6010A, 6015A

0754-0404

fxd film 130 5% 1/4W

R150

6011A, 6012B

0683-2715

fxd film 270 5% 1/4W

R151

All

0683-4725

fxd film 4.7K 5% 1/4W

R152

All

0757-0442

fxd film 10K 1% 1/8W

R153

All

0757-0443

fxd film 11K 1% 1/8W

R154

All

0757-0451

fxd film 24.3K 1% 1/8W

R155

All

0757-0444

fxd film 12.1K 1% 1/8W

R156

All

0683-4725

fxd film 4.7K 5% 1/4W

R157

All

0683-1005

fxd film l0 52 1/4W

R158

All

0686-2005

fxd comp 20 5% 1/2W

R159,160

All

0686-6215

fxd comp 620 5% 1/2W

R161

All

0757-0283

fxd film 2K 1% 1/8W

R162

All

0757-0442

fxd film l0K 1% 1/8W

R163

All

0757-0283

fxd film 2K 1% 1/8W

R164

All

0757-0434

fxd film 3.65K 1% 1/8W

R165

All

0683-1035

fxd film 10K 5% 1/4W

R166,167

All

0686-1315

fxd comp 130 5% 1/2W

R168

All

0683-1515

fxd comp 150 5% 1/4W

R169

All

0757-0124

fxd film 39.2K 1% 1/8W

R170

All

0698-3136

fxd film 17.8K 1% 1/8W

R171

All

0757-0280

fxd film 1K 1% 1/8W

R172

All

0811-3174

fxd WW .07 5% 5W

R173

All

0683-2225

fxd film 2.2K 5% 1/4W

R174

All

0683-3625

fxd film 3.6K 5% 1/4W

R175

All

0683-1525

fxd film 1.5K 55 1/4W

R176

All

0683-2225

fxd film 2.2K 5% 1/4W

68

Image 68
Contents Autoranging DC Power Supply Agilent Models 6010A, 6011A Certification Safety Summary Safety Symbol Definitions Table of Contents Replaceable Parts Troubleshooting Circuit DiagramsSafety Considerations ScopeManual Revisions Item DescriptionCalibration Procedure IntroductionTest Equipment Required Operation Verification TestsType Required Characteristics USE Recommended Model Test Equipment Required4KVA Initial Setup Calibration ProcedureMON Iout Display SettingsVout Common Mode Setup CR4 Performance TestsMeasurement Techniques Current-Monitoring Resistor Setup Basic Test Setup Constant Voltage CV TestsPage RMS Measurement Test Setup, CV Pard Test Peak-To-Peak Measurement Test Setup, CV Pard Test 6012B 6015A 6010A 6011ANot Applicable Load Transient Recovery Waveform 6010A 6011A 6012B 6015AConstant Current CC Tests Page CC Pard Test Setup Troubleshooting Initial Troubleshooting ProceduresControl Board Test Connector, A2J7 VdcRepair and Replacement Electrostatic ProtectionA2 Control Board Removal A4 FET Board RemovalA1 Main Board Removal A5 Diode Board RemovalA3 Front Panel Board Removal A3 Front Panel Assembly Rear View Overall Troubleshooting ProcedureA1 Designator Wire color A3S1 Position Rear View Using the Tables Main Troubleshooting SetupMain Troubleshooting Setup Modified Mains Cord Set For Troubleshooting Troubleshooting No-Output Failures Front Panel TroubleshootingA2J7-26 A2J7-25 Performance Failure Symptoms Troubleshooting Bias SuppliesA3 Front Panel Board Failure Symptoms Node + Node + N0DEPower Section Blocks Troubleshooting AC-Turn-on CircuitsTroubleshooting PWM & Clock AC FaultRelay Enable + OUTTroubleshooting DC-To-DC Converter Troubleshooting Down ProgrammerPWM-ON PWM-OFFWaveforms Troubleshooting CV Circuit Troubleshooting CC CircuitON/OFF OFFTroubleshooting OVP Circuit SET Voltage Setup MeasurementPage System Description Autoranging PowerOverview Regulation & Control Subsystem A and 6015A Simplified Schematic A and 6012B Simplified Schematic Input from Output to Quick Reference Guide to Major Circuits Major FunctionOperation PWM DP DP PWMInput Power Subsystem Protection SubsystemFront Panel Board DC Power Conversion SubsystemOutput Subsystem Page Simplified Front Panel Schematic Replaceable Parts Reference DesignatorsOrdering Information Description AbbreviationsMain Board Assembly CB1 CR1CR2 CR5VR1 A1 Mechanical6010A C37 6010A, 6011A, 6015A Not Used Not Used Not Used Page Not Used VR6 VR2VR5 TB1 TB2Not Used VR1 VR2 Agilent ModelTS1 Drvr TTL NOR DualFET N-CHAN CR3CR6 A5 Mechanical A6 Mechanical Chassis Electrical Not Used Component Location and Circuit Diagrams Schematic Diagram NotesIndicate number of paths represented by the line Top View, Top Covers Removed Main Board A1 and Filter Board A6 Component Location Control Board A2 Component Location Front Panel Board A3 Component Location FET Board A4 Component Location Diode Board A5 Component Location Page Page Page Page Option 002 Hardware SpecificationsGeneral Information Table A-1. Specifications, Option Remote Programming Input Compliance Voltage ± Current Programming EnableStatus Indicators AccuracyRemote Trip and Remote Reset Timing Power-on PresetMaximum Output Voltage logic high + On State logic lowTable A-1. Specifications, Option Pulse Timing Bias Supplies DC Output Ratings 25C ±Short Circuit Output Current Pard TypicalInstallation Connector Assembly ProcedureFigure A-1. Mating Connector Assembly OperationLocal/Remote Programming Resistance Voltage or Current Remote Resistance Programming Figure A-4. Calculating Value of Series Dropping ResistorFigure A-5. Remote Resistance Programming Remote Monitoring 101102 Status IndicatorsRemote Control 103 Remote ResetOvervoltage Power-On Preset 104105 AC Dropout Buffer CircuitMultiple Supply System Shutdown 106 MaintenanceBias Supplies 107 Troubleshooting Resistance and Voltage ProgrammingTroubleshooting Current Programming Figure A-11. Troubleshooting Current Programming of CV Mode 108Figure A-13. Troubleshooting Status Indicators 109110 Table A-3. Replacement Parts 111112 VR9 113114 Logic Symbols and DefinitionsIndicator and Qualifier Symbols Schematic Diagram Notes 115Schematic Notes Figure A-15. Option 002 Board, Component Location 116Figure A-16. Option 002 Board, Schematic Diagram 117 Page 119 Model 6010A ChangeModel 6011A Change 120 Model 6012B ChangeModel 6015A Change Delete 121122 123 124 DS5 125126
Related manuals
Manual 48 pages 27.24 Kb

6015A, 6012B, 6011A, 6010a specifications

Agilent Technologies, a leader in the field of measurement and analysis, offers a suite of instruments within its 6010 and 6011 series, specifically the 6010A, 6011A, 6012B, and 6015A models. These devices are designed to meet the needs of various industries, including healthcare, environmental monitoring, and materials testing.

The Agilent 6010A is a high-performance spectrometer known for its precision and versatility. It utilizes advanced optical technologies to provide exceptional wavelength accuracy and resolution. This model is particularly useful in laboratories where reliable data is critical, offering a wide spectral range and effective noise reduction features. Its user-friendly interface simplifies complex analyses, making it suitable for both seasoned professionals and newcomers.

Following closely, the Agilent 6011A is recognized for its robust capabilities in laboratory environments. This device incorporates advanced signal processing techniques, enabling high-throughput measurements without compromising on quality. The 6011A is ideal for real-time monitoring applications, ensuring that users can make informed decisions based on accurate, timely data. Its comprehensive software suite is designed to enhance data analysis, allowing for seamless integration with existing laboratory workflows.

The 6012B variant enhances the functionality further by introducing additional features tailored for specific applications. With a focus on flexibility, the 6012B supports multiple measurement modes, including direct and differential detection. This model excels in complex measurements, allowing for greater analytical depth and insights. The built-in calibration options ensure consistent performance, making it a reliable choice for various research and development tasks.

Lastly, the Agilent 6015A model stands out with its leading-edge technology, designed for the most demanding applications. It boasts enhanced sensitivity and an improved dynamic range, making it perfect for trace analysis in challenging environmental samples. The 6015A’s advanced reporting tools provide detailed analytics, helping scientists and researchers interpret results efficiently. Its compact design also makes it suitable for laboratory spaces with limited room, without sacrificing performance.

Together, these models showcase Agilent Technologies' commitment to delivering high-quality, innovative solutions that empower users to achieve their analytical goals effectively and efficiently. Whether in a research, clinical, or industrial setting, the 6010A, 6011A, 6012B, and 6015A continue to set standards in precision instrumentation.