“AUTOCAL” Feature
When a DDM is installed in the PowerCharger, a special InterActive mode is automatically enabled for DIGITAL batteries placed on the PowerCharger at any time. The PowerCharger will interrogate the status of the DIGITAL battery to determine whether the battery has received a “learning” cycle or “calibrate” cycle within certain parameters. This “learning” typically occurs in normal equipment operation, however, if the battery has not been fully charged and discharged in some time, a “double arrow” or “calibrate” indication will appear on the battery. The DIGITAL battery will continue to function normally with this indication. It is a request by the battery to fully charge and discharge the battery to the “EOD” point at the next opportune time so that the battery can verify its capacity. See DIGITAL battery Owner’s Manual for complete description of this indication.
The PowerCharger with DDM will detect a request from the DIGITAL battery and automatically enter an AUTOCAL mode when the battery is placed on the charger. This mode is indicated by the PowerCharger with an audible alert and a message in the LCD advising that the AUTOCAL routine has been called. This mode can be canceled, for example, if time constraints do not allow for the test to be completed. The mode is identical to the
The AUTOCAL mode can be canceled by following the prompts appearing in the LCD, using the TEST button to cancel the test. If the test is not canceled, it will commence automatically.
When the AUTOCAL operation is complete, the battery will be fully charged and ready for use.
9