Royal Sovereign RSH-380SL service manual Rollers Not Running, No power to the unit

Page 7

4.Defective Main PCB.

a. Replace the PCB Main.

2.3Rollers Not Running

CAUSES

1.No power to the unit.

2.The main switch is close.

3.Opened safety cover.

4.Film is jammed on the rollers.

5.Disconnected motor wire.

6.Defective main motor.

7.Defective main PCB.

MEASURES

1.No power to the unit.

a. Make sure the power plug is connected to the proper source of outlet

2.The main switch is close.

Main Switch

3.Opened safety cover.

a. Close the safety cover and double check to insure that the safety cover switch is engaged.

Note: By closing the safety cover, it engages the safety cover switch.

5

Image 7
Contents MODELRSH-380SL Table of Content Safety Precautions Wire-HeaterWire-Heater TroubleshootingRollers Not Heating Blown burnt wire fuse T/Fuse Wire-Temp. FuseWire-T / Fuse Connector-Wire SensorRollers Over Heating Rollers Not Running No power to the unitMotor Switch is engagedNo Electricity Main Power WiresNo Main Power Main FuseTransformer is defective a. Replace the transformer Problem CurlingPoor Lamination Quality Replacing the Main PCB Replacing PartsReplacing the Right Cover Replacing the Sub-PCBReplacing the Heaters Adjusting front and rear rollers Pressure AdjustmentsPart List Front Table Safety Lever Spcc 1.5T PCB-SUB Assy Explode View VCC5V Wire DiagramConnect part Bimetal135 SUB PCBWire T/Fuse Micro Switch Wire Safety S/W Wire Motor