Royal Sovereign RSH-380SL service manual Wire-Temp. Fuse, Blown burnt wire fuse T/Fuse

Page 5

2.Blown (burnt) wire fuse (T/Fuse).

a. Replace the T/Fuse wire located on the left-hand side.

Wire-Temp. Fuse

3.Defective Bi-Metal.

a. Replace the Bi-Metal

Bi-metal (135)

4.Defective heater.

a. Using the multi-meter, test the continuity of the heater. If it fails, replace the heater.

Multi-meter

b. Physically examine the heater assembly for breakage.

Broken

3

Image 5
Contents MODELRSH-380SL Table of Content Safety Precautions Rollers Not Heating TroubleshootingWire-HeaterWire-Heater Blown burnt wire fuse T/Fuse Wire-Temp. FuseRollers Over Heating Connector-Wire SensorWire-T / Fuse Rollers Not Running No power to the unitMotor Switch is engagedNo Main Power Main Power WiresMain Fuse No ElectricityPoor Lamination Quality Problem CurlingTransformer is defective a. Replace the transformer Replacing the Right Cover Replacing PartsReplacing the Sub-PCB Replacing the Main PCBReplacing the Heaters Adjusting front and rear rollers Pressure AdjustmentsPart List Front Table Safety Lever Spcc 1.5T PCB-SUB Assy Explode View VCC5V Wire DiagramConnect part Bimetal135 SUB PCBWire T/Fuse Micro Switch Wire Safety S/W Wire Motor