5.Defective Main PCB.

a. Replace the PCB Main.

2.2Rollers Over Heating

CAUSES

1.Heat sensor is reversed on the PCB Main.

2.Defective T/Fuse wire.

3.Defective heater.

4.Defective main PCB.

MEASURES

1.Wires for lower and upper heat sensors are reversed on the main PCB. a. Reverse the heat sensors.

Connector-Wire Sensor

2.Defective T/Fuse wire.

a. Replace the T/Fuse wire located on the left-hand side.

Wire-T / Fuse

3.Defective heater.

a.Test continuity of the heater. If it fails, replace the heater.

b.Glass tube that surrounds heating coil is broken – replace the heating element.

4

Image 6
Contents MODELRSH-380SL Table of Content Safety Precautions Troubleshooting Wire-HeaterWire-HeaterRollers Not Heating Wire-Temp. Fuse Blown burnt wire fuse T/FuseConnector-Wire Sensor Wire-T / FuseRollers Over Heating No power to the unit Rollers Not RunningSwitch is engaged MotorMain Fuse Main Power WiresNo Main Power No ElectricityProblem Curling Transformer is defective a. Replace the transformerPoor Lamination Quality Replacing the Sub-PCB Replacing PartsReplacing the Right Cover Replacing the Main PCBReplacing the Heaters Adjustments Adjusting front and rear rollers PressurePart List Front Table Safety Lever Spcc 1.5T PCB-SUB Assy Explode View Wire Diagram VCC5VConnect part SUB PCB Bimetal135Wire T/Fuse Micro Switch Wire Safety S/W Wire Motor