APC 1250, 2000, 900 user manual Operation, Display features

Page 20

5.0Operation

5.1Display features

On Battery

On, Test, Alarm

SmartBoost

Replace

On Line indicator

disable pushbutton

indicator

Battery

indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indicator

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery

 

 

 

 

 

 

 

 

 

 

 

bar graph

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

capacity & line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power standby

 

 

 

 

 

 

 

 

 

 

 

voltage bar

 

 

 

 

 

 

 

 

 

 

 

pushbutton

 

 

 

 

 

 

 

 

 

 

 

graph

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.1.1 On / Test / Alarm disable pushbutton

The On / Test / Alarm disable pushbutton is used to control activation of the UPS and to energize the load. Once the UPS is energized, pressing the button will initiate a battery test. This will force the UPS to operate on-battery for a brief time during which the UPS determines the strength of the battery. When the UPS is on-battery, this button may be pressed to silence the utility failure audible warning.

5.1.2 Power standby pushbutton

When held pressed for a second, this control will deenergize the UPS and all protected loads. However, operation of the UPS's battery charger is unaffected by this control.

5.1.3 On Line indicator

Illumination of the On Line indicator means that the load is being supplied conditioned power derived from the utility service. The indicator blinks during the battery test.

5.1.4 On Battery indicator

Illumination of the On Battery indicator means that load has been transferred to power derived from the UPS's battery and that utility voltage is not within normal limits.

5.1.5 Smart Boost indicator

Illumination of SmartBoost indicator means that the SmartBoost circuitry has been engaged to compensate for unacceptably low line voltage. The UPS is capable of operating in this mode continuously without draining charge from the battery.

5.1.6 Replace Battery indicator

Illumination of the Replace Battery indicator means that the automatic battery test has found that the battery is weak and requires replacement. The indicator is extinguished following a successful battery test.

Page18

Image 20
Contents Smart-UPS Important safety instructions Radio Frequency InterferenceTable of contents Introduction OverviewBattery replacement indicators and test SmartBoostRemote interfaces Extended capabilitiesSafety EnglishSécurité Sicherheit Deutsch¡ Seguridad Presentation 900VA and 1250VA models 100, 120 Vac versionsFront view Rear view900VA and 1250VA models 220/230/240 Vac version 2000VA model 100, 120 Vac versions Front view Rear view2000VA model 120 Vac versions options Option2000VA model 208 Vac version and options Standard Option2000VA model 220/230/240 Vac version Receiving inspection InstallationPlacement Connect UPS to service Connect battery pack 2000VA model onlyConnect UPS to service and enable Enable UPS Check Site Wiring Fault indicator 100, 120 Vac versions Switch on load equipmentSwitch on the UPS Plug loads into UPSDisplay features OperationBattery capacity bar graph Output power bar graphAudible alarm On-battery operationLow battery Line voltage bar graphOption switches Replace batteryOption switch OverloadPage22 Status reporting MonitoringPower management Operation customizingPage25 Interface Kits PowerChute SoftwareUPS Monitoring Computer interface port Difficulty Difficulté Schwierigkeit Dificultad Troubleshooting chart GifOcSd GfkkWOcS PNmkS NPlWfe lf lNbSBattery replacement check Obtaining Service Extended storage Storing the UPSStorage conditions Specifications Transfer characteristicsOutput characteristics InputBattery and charger Noise and surge suppressionEnvironment PhysicalTypical run time versus load Cy˜ E66nN 78A6nN 8666nN ¡y ¡¸ y˜ 64C 3y I oyPage39 Declaration of Conformity Limited Warranty Life support policy∗ Mailing

900, 1250, 2000 specifications

The APC series, particularly models 2000, 1250, and 900, represents a cornerstone in the uninterruptible power supply (UPS) landscape, providing robust solutions for protecting sensitive electrical equipment from power disruptions. These models are designed to ensure high availability and power reliability for a range of applications, from personal use to larger enterprise systems.

The APC 2000 is known for its high power capacity, rated at 2000VA/1600W. It features an advanced LCD interface that provides essential information, such as battery status and load capacity. This model incorporates pure sine wave output, making it ideal for devices that require a stable and clean power source. It also offers multiple outlets and communication ports, including USB and SmartSlot for additional network management capabilities. The integration of PowerChute software allows users to efficiently monitor and manage the UPS, ensuring proactive response to any power-related issues.

The APC 1250, with a capacity of 1250VA/750W, is tailored for medium-sized setups. Its compact design makes it suitable for small offices and home workstations. The model boasts similar features to the 2000, including an intuitive LCD display and pure sine wave output. The APC 1250 also provides automatic voltage regulation, ensuring that connected devices receive consistent voltage without unnecessary battery usage. The unit’s design prioritizes user-friendliness with tools for easy installation and monitoring.

Meanwhile, the APC 900 operates at 900VA/480W, catering specifically to individual users and smaller electronics. This model is designed for basic use, such as providing backup power for personal computers, networking equipment, or smaller electronics. The APC 900’s standout features include user-friendly status indicators, fuse protection, and several outlets to ensure multiple devices can be connected simultaneously. Its compact size makes it particularly appealing for home environments where space is at a premium.

Each of these models leverages cutting-edge technologies including advanced battery management systems that prolong battery life and performance. They incorporate surge protection and noise filtering to safeguard sensitive equipment. In terms of physical characteristics, the UPS units are built with a focus on durability and ease of transport, featuring sturdy casings and integrated handles.

In conclusion, the APC 2000, 1250, and 900 models offer a range of features that cater to diverse power needs, ensuring reliable power protection and management for both personal and business applications. Their deployment of advanced technologies and user-friendly functionalities make them a preferred choice in the UPS market.