APC 900, 2000, 1250 user manual Limited Warranty, Life support policy

Page 43

Limited Warranty

American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authoriza- tion (RMA) number from APC or an APC service center. Products must be returned to APC or an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence, or mis-application or has been altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase.

EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO WAR- RANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAM- AGE. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Life support policy

As a general policy, American Power Conversion (APC) does not recommend the use of any of its products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. APC does not recommend the use of any of its products in direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances.

Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as “critical” by the U.S. FDA.

Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS systems. APC does not claim that units with this modification are certified or listed as Hospital Grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care.

Image 43
Contents Smart-UPS Radio Frequency Interference Important safety instructionsTable of contents Overview IntroductionExtended capabilities Battery replacement indicators and testSmartBoost Remote interfacesEnglish SafetySécurité Deutsch Sicherheit¡ Seguridad Rear view Presentation900VA and 1250VA models 100, 120 Vac versions Front view900VA and 1250VA models 220/230/240 Vac version Front view Rear view 2000VA model 100, 120 Vac versionsOption 2000VA model 120 Vac versions optionsStandard Option 2000VA model 208 Vac version and options2000VA model 220/230/240 Vac version Placement InstallationReceiving inspection Connect UPS to service and enable Connect battery pack 2000VA model onlyConnect UPS to service Enable UPS Plug loads into UPS Check Site Wiring Fault indicator 100, 120 Vac versionsSwitch on load equipment Switch on the UPSOperation Display featuresOutput power bar graph Battery capacity bar graphLine voltage bar graph Audible alarmOn-battery operation Low batteryOverload Option switchesReplace battery Option switchPage22 Monitoring Status reportingOperation customizing Power managementPage25 UPS Monitoring PowerChute SoftwareInterface Kits Computer interface port Difficulty Difficulté Schwierigkeit Dificultad GifOcSd GfkkWOcS PNmkS NPlWfe lf lNbS Troubleshooting chartBattery replacement check Obtaining Service Storage conditions Storing the UPSExtended storage Input SpecificationsTransfer characteristics Output characteristicsPhysical Battery and chargerNoise and surge suppression EnvironmentCy˜ E66nN 78A6nN 8666nN ¡y ¡¸ y˜ 64C 3y I oy Typical run time versus loadPage39 Declaration of Conformity Life support policy Limited Warranty∗ Mailing

900, 1250, 2000 specifications

The APC series, particularly models 2000, 1250, and 900, represents a cornerstone in the uninterruptible power supply (UPS) landscape, providing robust solutions for protecting sensitive electrical equipment from power disruptions. These models are designed to ensure high availability and power reliability for a range of applications, from personal use to larger enterprise systems.

The APC 2000 is known for its high power capacity, rated at 2000VA/1600W. It features an advanced LCD interface that provides essential information, such as battery status and load capacity. This model incorporates pure sine wave output, making it ideal for devices that require a stable and clean power source. It also offers multiple outlets and communication ports, including USB and SmartSlot for additional network management capabilities. The integration of PowerChute software allows users to efficiently monitor and manage the UPS, ensuring proactive response to any power-related issues.

The APC 1250, with a capacity of 1250VA/750W, is tailored for medium-sized setups. Its compact design makes it suitable for small offices and home workstations. The model boasts similar features to the 2000, including an intuitive LCD display and pure sine wave output. The APC 1250 also provides automatic voltage regulation, ensuring that connected devices receive consistent voltage without unnecessary battery usage. The unit’s design prioritizes user-friendliness with tools for easy installation and monitoring.

Meanwhile, the APC 900 operates at 900VA/480W, catering specifically to individual users and smaller electronics. This model is designed for basic use, such as providing backup power for personal computers, networking equipment, or smaller electronics. The APC 900’s standout features include user-friendly status indicators, fuse protection, and several outlets to ensure multiple devices can be connected simultaneously. Its compact size makes it particularly appealing for home environments where space is at a premium.

Each of these models leverages cutting-edge technologies including advanced battery management systems that prolong battery life and performance. They incorporate surge protection and noise filtering to safeguard sensitive equipment. In terms of physical characteristics, the UPS units are built with a focus on durability and ease of transport, featuring sturdy casings and integrated handles.

In conclusion, the APC 2000, 1250, and 900 models offer a range of features that cater to diverse power needs, ensuring reliable power protection and management for both personal and business applications. Their deployment of advanced technologies and user-friendly functionalities make them a preferred choice in the UPS market.