5.0 Operation

5.7 Extended capabilities - continued

Output voltage, internal temperature, battery voltage, battery capacity - The UPS continuously monitors the rms output voltage, internal temperature in degrees Celsius, battery voltage, and the remaining battery capacity as a percentage of the fully charged condition. This information is valuable for troubleshooting purposes.

5.7.3 Power management

Shut down - While operating on-battery, the UPS may be directed to shut down following a user set delay. Controlled shut down of the UPS conserves battery capacity and extends battery life because the UPS is not allowed to run until all battery capacity is exhausted.

Shut down with delayed restart - The UPS may be directed to shut down in any mode following a user set delay, then restart after another user set delay. The restart delay may be used to stagger power up multiple network servers protected by multiple UPSs.

Simulate power failure - The UPS may be directed to simulate a power failure by briefly operating on-battery. This function is useful for test purposes.

Turn off - The UPS may be directed to turn off immediately or following a user settable delay.

5.7.4 Operation customizing

Alteration of many UPS operations is possible to suit specific applications. In order to use the customizing features of the UPS, all Option switches must be set to the on ( I ) position. Functionality of the option switches is not lost as all such functions are duplicated by the UPS monitoring software. Once any of the Option switches are returned to the off position, functionality governed by the position of all Option switches is also restored.

Battery test operation - The battery test can be customized to automatically run upon startup, upon startup and once every 7 days thereafter, upon startup and once every 14 days thereafter, or never. The UPS’s battery test operation default setting is upon start and every 14 days thereafter.

Transfer voltage - The UPS’s upper and lower transfer voltages can be customized over a wide range. Default settings are given in section 9.0.

Page24

Image 26
Contents Smart-UPS Important safety instructions Radio Frequency InterferenceTable of contents Introduction OverviewRemote interfaces Battery replacement indicators and testSmartBoost Extended capabilitiesSafety EnglishSécurité Sicherheit Deutsch¡ Seguridad Front view Presentation900VA and 1250VA models 100, 120 Vac versions Rear view900VA and 1250VA models 220/230/240 Vac version 2000VA model 100, 120 Vac versions Front view Rear view2000VA model 120 Vac versions options Option2000VA model 208 Vac version and options Standard Option2000VA model 220/230/240 Vac version Receiving inspection InstallationPlacement Connect UPS to service Connect battery pack 2000VA model onlyConnect UPS to service and enable Enable UPS Switch on the UPS Check Site Wiring Fault indicator 100, 120 Vac versionsSwitch on load equipment Plug loads into UPSDisplay features OperationBattery capacity bar graph Output power bar graphLow battery Audible alarmOn-battery operation Line voltage bar graphOption switch Option switchesReplace battery OverloadPage22 Status reporting MonitoringPower management Operation customizingPage25 Interface Kits PowerChute SoftwareUPS Monitoring Computer interface port Difficulty Difficulté Schwierigkeit Dificultad Troubleshooting chart GifOcSd GfkkWOcS PNmkS NPlWfe lf lNbSBattery replacement check Obtaining Service Extended storage Storing the UPSStorage conditions Output characteristics SpecificationsTransfer characteristics InputEnvironment Battery and chargerNoise and surge suppression PhysicalTypical run time versus load Cy˜ E66nN 78A6nN 8666nN ¡y ¡¸ y˜ 64C 3y I oyPage39 Declaration of Conformity Limited Warranty Life support policy∗ Mailing

900, 1250, 2000 specifications

The APC series, particularly models 2000, 1250, and 900, represents a cornerstone in the uninterruptible power supply (UPS) landscape, providing robust solutions for protecting sensitive electrical equipment from power disruptions. These models are designed to ensure high availability and power reliability for a range of applications, from personal use to larger enterprise systems.

The APC 2000 is known for its high power capacity, rated at 2000VA/1600W. It features an advanced LCD interface that provides essential information, such as battery status and load capacity. This model incorporates pure sine wave output, making it ideal for devices that require a stable and clean power source. It also offers multiple outlets and communication ports, including USB and SmartSlot for additional network management capabilities. The integration of PowerChute software allows users to efficiently monitor and manage the UPS, ensuring proactive response to any power-related issues.

The APC 1250, with a capacity of 1250VA/750W, is tailored for medium-sized setups. Its compact design makes it suitable for small offices and home workstations. The model boasts similar features to the 2000, including an intuitive LCD display and pure sine wave output. The APC 1250 also provides automatic voltage regulation, ensuring that connected devices receive consistent voltage without unnecessary battery usage. The unit’s design prioritizes user-friendliness with tools for easy installation and monitoring.

Meanwhile, the APC 900 operates at 900VA/480W, catering specifically to individual users and smaller electronics. This model is designed for basic use, such as providing backup power for personal computers, networking equipment, or smaller electronics. The APC 900’s standout features include user-friendly status indicators, fuse protection, and several outlets to ensure multiple devices can be connected simultaneously. Its compact size makes it particularly appealing for home environments where space is at a premium.

Each of these models leverages cutting-edge technologies including advanced battery management systems that prolong battery life and performance. They incorporate surge protection and noise filtering to safeguard sensitive equipment. In terms of physical characteristics, the UPS units are built with a focus on durability and ease of transport, featuring sturdy casings and integrated handles.

In conclusion, the APC 2000, 1250, and 900 models offer a range of features that cater to diverse power needs, ensuring reliable power protection and management for both personal and business applications. Their deployment of advanced technologies and user-friendly functionalities make them a preferred choice in the UPS market.