Siemens 5930, 5935 manual Front Panel for, Back Panel for

Page 7

Chapter 1 Product Specifications

Front Panel for 5930

The following table explains the LEDs that appear on the front panel of the Siemens 5930 Business Gateway.

Light

Color

Indications

 

 

 

Power

Green

Power is ON

 

Off

Power is OFF

 

 

 

Test

Yellow:

Running Power On Self Test

 

Yellow flashing:

Self Test Failure

 

Green: (2 sec blink)

Self Test successful (heartbeat)

 

Off:

Router is shut down

 

 

 

WAN

Yellow:

Establishing DSL modem link

 

Yellow flashing:

Establishing DSL throughput

 

Green:

DSL modem link successful

 

Off:

DSL modem link is shut down

 

 

 

LAN

Green flashing:

Data traffic detected

 

Green:

LAN status - OK

 

Off:

LAN status - Not OK

 

 

 

Back Panel for 5930

The following table describes the various connections on the back panel of the Siemens 5930 Business Gateway.

Connection

Function

 

 

Power

Uses a 12V DC/AC power adapter.

 

 

Ethernet Ports

Eight Ethernet T-100 switch ports (8-pin,

 

RJ-45)

 

 

Management Port

This 8-pin, RJ-45 port provides RS232

 

connectivity for console connections or a

 

dial backup analog (external) modem

 

connection.

 

 

Backup

A 6-pin RJ-11 port connects the internal

 

modem.

 

 

DSL/WAN Port

A 6-pin RJ-11 connects the DSL.

 

 

SIEMENS

1

Image 7
Contents 5930/5935 Software License Software License and Limited WarrantyGeneral Provisions Table of Contents Advanced Setup InstallationEasy Setup User SetupMonitoring Router Security SetupBack Panel for Front Panel forHardware Specifications for Software Specifications for Security PPP RFCFront Panel for Hardware Specifications for Software Specifications for IP Address Translation Package Contents Installation RequirementsPC Requirements Network Service Provider Requirements Hardware Installation Windows 98/ME PC ConfigurationSelect TCP/IP Protocol from the Network Protocols list Windows NTWindows Windows XP Mac OS Mac OSX Linux Establish Connection Configuring the RouterTo do this Refer to Router InformationSelect Protocol Access Easy Setup WizardBlock Net Bios Traffic Bridging EnabledIP Routing Enabled NAT EnabledPoint-to-Point Protocol over Ethernet over PPPoA Point-to-Point Protocol over Ethernet over RFC1483 RFC RFC 1483 MAC Encapsulated Routing MER Dynamic Host Configuration Protocol Local Area Network Configuration User Management User SetupAdding/Modifying a User Account Deleting a User Account None User LookupLocal RadiusTrusted Secure Mode ConfigurationUntrusted Configure the Radius Server Configure the TacPlus Server Class Functional Areas Management ClassesChange Password Telnet Web Access ControlNo access restrictions Click Save and RebootAdvanced Setup Router Clock Dhcp QoS Configure QoS Policy Siemens To the end Reorder QoS PoliciesBefore policy Routing Table Configuration Click Enable Dial Backup Dial BackupInternal Modem External Modem Switch Management Switch Mirror Configuration Switch Age Time ATM Traffic Shaping Unspecified Bit Rate Constant Bit RateReal-Time Variable Bit Rate Non Real-Time Variable Bit RateCommand Line Interface Security Setup NAT Default DisablePort Number Click Add IP Range Snmp PasswordEnter the New Password and New Password again Snmp IP FilterKey Generator Secure ShellConfigure SSH Load Keys Key Generator Firewall Scripts Firewall Rules Stateful FirewallConfigure Stateful Firewall View Dropped Packets Configure Firewall Rules Application Protocol/PortDelete Firewall Rules IKE/IPSec Configuration Easy IKE/IPSec Setup IKE Peers Advanced IKE/IPSec SetupIKE Peers Definition IKE Proposals Definition IKE IPSec Proposals Definition Siemens IKE IPSec Policies Definition Siemens VPN Log On System Summary Monitoring RouterRemote Connection Information Ethernet Interface InformationSystem Information IP Routing InformationPPPoE Session DiagnosticsATM Statistics Interface InformationFiles Information Routing Table InformationMemory Usage List All Configuration DataTCP/IP Statistics