Lifebreath 200MAX, 95MAX, 155MAX installation manual Installation, Location

Page 18

INSTALLATION

Location

The HRV/ERV must be located in a heated space where it will be possible to conveniently service the unit. Typically the HRV/ERV would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted. If a basement area is not convenient or does not exist, a utility or laundry room may be used

Attic installations are not normally recommended due to: A) the complexity of work to install

B) freezing conditions in the attic

C) difficulty of access for service and cleaning

Sufficient clearance at the front of the access door is required for servicing the air filters and core. A minimum of 25" (635

mm)clearance is recommended so the door can be opened. Four PVC reinforced polyester hanging straps are provided for hanging the HRV/ERV from the basement floor joists.

Mounting

The hanging straps should be attached to the unit at the top end corners (mounting screws are already located on the HRV/ERV case). Securely fasten the other end of the straps to the floor joists with wide head nails (not supplied), making sure the unit is level. The straps are designed to reduce the possibility of noise, resonance or harmonics; therefore using the full length of the strap between the HRV/ERV and the floor joists is recommended.

Connecting Appliances to the HRV/ERV

It is not recommended that any of the following appliances be connected to the HRV/ERV:

clothes dryer

range top

stovetop fan

central vacuum system

Lint, dust or grease will collect in the HRV/ERV, damaging the unit.

NOTE: Connecting any of these to the HRV/ERV will invalidate your warranty.

Installing the Drain Line and P-Trap (not on all models)

When defrosting, the HRV/ERV may produce some condensation. This water should flow into a nearby drain, or be taken away by a condensate pump. The HRV/ERV and all condensate lines must be installed in a space where the temperature is maintained above the freezing point.

At the bottom of the cabinet there are prepunched hole for the drain pan connectors (see below). Insert the drain spout through the hole in the drain pan. Do not forget the “O Ring” which seals the connector to the pan. REMEMBER TO HAND TIGHTEN ONLY the washer and lock nut which hold the drain connector in place.

Electrical

The HRV/ERV should be plugged into a standard designated (120VAC) electrical outlet with ground. It is not recommended that an extension cord be used for this appliance. If further wiring is required, then a licensed electrician should make all electrical connections. It is recommended that a separate 15 amp/120 volt circuit be used.

WARNING:

In order to prevent electric shock when cleaning or servicing the HRV/ERV, it is extremely important to confirm the polarity of the power line that is switched by the safety (disconnect) switch. The hot line (black) is the proper line to be switched. To confirm the proper polarity, use a voltmeter or test lamp to ensure there is no power after the switch when the door is open. Check between that point and ground (on the cabinet). This must be done as dwellings are occasionally wired improperly. Always make sure that the HRV/ERV is properly grounded.

Construct a P-Trap using the plastic tee connector. Cut two lengths of hose and connect each piece to an end of the “T” fitting, then connect the other ends to the two drain spouts. Allow the "T" fitting to point upwards, and connect the drain line. Tape or fasten base to avoid any kinks. This creates a “trap” which will hold some condensate and prevent odours from being drawn up the hose and into the fresh air supply of the HRVERV.

PRE-PUNCHED HOLES (2)

DRAIN PANDRAIN PAN

DRAIN

DRAIN

SPOUT

SPOUT

 

TAPE

TEE

CONNECTOR

TO DRAIN

Forming the "P" Trap

18

Image 18
Contents Contains 95MAX200ERVD Table of Contents ERV Questions & Answers Page Model 95MAX Engineering DataDimensions 155MAX inches mm Model 155MAXDimensions 200MAX inches mm Model 200MAXDimensions Maxtop inches mm Model MaxtopDimensions 195DCS Model 195DCSModel 300DCS Thermally CONDUCTIVE, Patented Aluminum CoreDimensions 200ERV inches mm Model 200ERVDimensions 200ERVD Model 200ERVDFunction & Control To select mode of operation for ControlAir Optional Remote Controls NEW! AIR Sentry AIR Quality SensorUsing the Dehumidistat MAX Port Specifications Installation LocationInstalling AIR Ducts Supply AIR Ducting Dampers and GrillesInstallation Diagrams Simplified Installation Supply/Return Method Fully Dedicated System Pitot Tube AIR Flow Balancing Balancing Collar Instructions Inspect Exterior Hoods at least once a month Maintenance Routine for ERV for HRV, see previous Symptom Cause Solution OccupantTechnical Bulletin Residential Wiring Diagram McCormick Blvd. London, Ontario N5W 4C
Related manuals
Manual 32 pages 16.73 Kb Manual 12 pages 19.73 Kb

155MAX, 95MAX, 200MAX specifications

Lifebreath is well-known for its innovative heat recovery ventilators that enhance indoor air quality while conserving energy. Among their acclaimed models, the Lifebreath 150SP, 200MAX, 150MAX, and 200STD stand out for both their functionality and design, delivering optimal performance for various residential and commercial applications.

The Lifebreath 150SP is designed for spaces requiring effective air exchange while maintaining energy efficiency. This model boasts a compact design, making it ideal for smaller homes or apartments. One of its main features includes a top-mounted control panel with a user-friendly interface, allowing for easy adjustment of settings. Equipped with a high-efficiency heat exchanger, the 150SP effectively transfers heat from the outgoing stale air to the incoming fresh air, minimizing energy loss. Additionally, the unit operates quietly, ensuring that comfort is not compromised.

On to the 200MAX, this model is engineered for larger spaces. With increased airflow capacity, it ensures consistent air quality in bigger areas while optimizing energy consumption. The 200MAX features advanced filtering systems that capture dust, pollen, and other allergens, promoting a healthier indoor environment. Its built-in defrosting system operates automatically, enhancing efficiency during colder months. The 200MAX also supports optional accessories, such as a programmable timer and an energy recovery ventilator, allowing users to customize performance to meet specific needs.

The Lifebreath 150MAX pairs the efficiency of the 150SP with added versatility. This model is suitable for mid-sized spaces and comes equipped with a dual motor system. This unique feature provides users with the flexibility to adjust airflow independently, accommodating varying room conditions. The 150MAX excels in both heating and cooling modes, ensuring comfort year-round.

Finally, the Lifebreath 200STD offers a straightforward approach to ventilation without compromising on performance. Designed for standard residential applications, the 200STD is easy to install and maintain, featuring a washable pre-filter. This model is energy efficient and operates quietly while delivering excellent air exchange rates, making it perfect for families seeking reliable indoor air management.

In conclusion, the Lifebreath range—150SP, 200MAX, 150MAX, and 200STD—showcases superior design and cutting-edge technology. With their focus on energy efficiency, user comfort, and adaptable features, Lifebreath models uphold a promise of high indoor air quality and sustainable living. These systems not only contribute to a healthier environment but also reduce energy costs, making them an ideal investment for any modern building.