Users Manual TOPAS900 Flash V2.1
up the following window occurs (fig. 9) and the board reacts by red LED flashing quickly. Be sure that the jumper J_EA is opened.
Figure 14 : Flash Programmer Window
All bars and icons are self explaining. It should be noticed that either internal or external flash memory can be selected and programmed. Files to be downloaded have to be in HEX16 or HEX20 format. Conversion tools are available in both tool sets.
It is important to mention that the ROM Monitors have to be located in the external flash. Hence the reprogramming procedure is to choose the access “External Flash” then “Erase Flash” then open alternatively the files “iar.h20” for IAR or “toshiba.h20” for Toshiba ROM Monitor and then “Program Flash”. Both files are to be found in “Program Files/topas900flash/monitors”.
HWU Elektronik Oberhausen | Page 35 |