Toshiba TIC-LF494B manual Specification Code Sanitary type detector LF490 Series

Page 12

TIC-LF494B

Table 5. Specification Code (Sanitary type detector LF490 Series)

 

Model

 

 

Specification Code

 

Description

Type

1

2

3

4

5

6

7

8

9

10 11 12 13 14

 

Normal

Ex. type

 

 

L

F

4

9

0

 

 

 

 

 

Normal specification type

L

F

4

9

4

 

 

 

 

 

Hazardous location certification type (Note 1)

 

 

 

 

 

 

 

 

 

 

 

Meter size

(Clamp size)

 

 

 

 

 

E

 

 

 

 

1"(25mm)

(2S)

 

 

 

 

 

F

 

 

 

 

1 1/2"(40mm)

(2 1/2S)

 

 

 

 

 

G

 

 

 

 

2"(50mm)

(3S)

 

 

 

 

 

H

 

 

 

 

3"(80mm)

(4S)

 

 

 

 

 

J

 

 

 

 

4"(100mm)

(5 1/2S)

 

 

 

 

 

 

 

 

 

 

Mounting Style

 

 

 

 

 

 

 

 

L

 

 

 

Detector/Converter combined type (LF490/LF610)

 

 

 

 

 

 

 

M

 

 

 

Detector/Converter separate type (LF490/LF612)

 

 

 

 

 

 

 

 

 

 

 

cFMus class I, Division 2 (Note 1)

 

 

 

 

 

 

 

A

 

 

 

Detector/Converter combined type (LF494/LF610F)

 

 

 

 

 

 

 

B

 

 

 

Detector/Converter separate type (LF494/LF612F)

 

 

 

 

 

 

 

 

 

 

 

Connection method

 

 

 

 

 

 

 

 

 

A

 

 

Sanitary clamp type (ISO 2852) (Note 2)

 

 

 

 

 

 

 

 

 

Z

 

 

Other

 

 

 

 

 

 

 

 

 

 

 

 

Electrode Material (Note 5)

 

 

 

 

 

 

 

 

 

 

B

 

316L stainless steel

 

 

 

 

 

 

 

 

 

 

Z

 

Other

 

 

 

 

 

 

 

 

 

 

 

 

Lining and Sealing materials (gaskets) (Note 5)

 

 

 

 

 

 

 

 

 

 

 

S

Teflon PFA and Silicone rubber

 

 

Piping connection parts (ferrules, clamps) (Note 2, 3, 5)

ANo ferrule and no clamp

BNormal type of Ferrules (304 stainless steel) with no clamp

CNormal type of Ferrules (304 stainless steel) with clamp

DLong type of Ferrules (304 stainless steel) with no clamp

ELong type of Ferrules (304 stainless steel) with clamp

Z

Other

 

Flow and calibration velocity range

 

A1.0 to 32.8 ft/s (standard range calibration)

B1.0 to 32.8 ft/s (specified range calibration)

C0.3 to 32.8 ft/s (specified range calibration)

Excitation and Signal Cables

Anot provided

B30 m cable, provided (Note 4)

Cother lengths, provided (Note 4)

Coating (Note 6)

A

no coating

 

 

F

3A approved type

Z

Other

 

Size code explanation: : Object

: Standard

: Option

–: Not available

Note1: Cable glands are not provided. Refer to the part of “Cable connection port” at detector and converter.

Note2: Tri-clamp® is available to use the same joint size instead of ISO2852 clamp except meter size 100mm (4").

Note3: Toshiba’s original ferrule is required to use for LF490 series detectors to keep just fitting between the joint in case of choosing clamp type.

Note4: Applies to the separate type flowmeter only. Specifying the code C, indicate the length of cable from 1 to 300m in 1 meter increments.

Note5: Consult Toshiba before ordering when choose materials at the wetting parts.

Note6: LF494 have only 3A approved type.

12

Image 12
Contents Introduction Combined type Separate typeSpecifications Overall SpecificationsModel LF490 and LF494 Detectors Model LF610 and LF612 converters Power supply Dimensions and WeightsSurge protection Cable connection ports Cable glandsInstallation Dimensions Combined typeDimensions Separate type Ferrule dimensions External Connections Combined type LF490/LF610 and LF494/LF610F flowmetersSeparate type LF490/LF612 and LF494/LF612F flowmeters Wiring Precautions Wiring Precautions ProfibusMeter Size To select the meter sizeOrdering Information Calibration RangeStandard Flow Range About establishment environmentSpecification Code Sanitary type detector LF490 Series Specification Code for converters Type Specification Code for Maintenance PartsThis Page Intentionally Blank TIC-LF494B ISO9001 and ISO14001 are certified