Toshiba TIC-LF494B manual Dimensions Separate type

Page 6

TIC-LF494B

Dimensions (Separate type)

Clamp connection

 

 

Unit : inch(mm)

3.46(88)

 

4.96(126)

1.57(40)

1.38(36)

3.58(91)

Welding connection

 

 

Unit : inch(mm)

3.46(88)

 

4.96(126)

1.57(40)

1.38(36)

3.58(91)

R(PT)1/2

Male screw

(L2)

R(PT)1/2

Male screw

ΦD1

L1

(単位:mm)

φD2

φD1

L1

Note1: Clamp (Joint) size is different from meter size of LF490. See the following table.

Note2: Cable glands are not provided for cFMus approved type.

For English unit

Note1: L1 dimension is for the standard (Normal length) type ferrule.

Note2: See Figure 7 for Ferrule dimensions.

Note3:Cable glands are not provided for cFMus approved type.

For English unit

Meter size

Joint size

L1

L2

D1

Weight

(inch)

(ISO2852)

(inch)

(inch)

(inch)

(lbs)

1 (1S)

2 S

4.33

7.05

2.87

approx. 8.8

1-1/2 (1-1/2S)

2 1/2 S

4.92

7.72

3.54

approx. 11.0

2 (2S)

3 S

5.51

8.27

4.09

approx. 13.2

3 (3S)

4 S

5.51

9.29

5.12

approx. 17.6

4 (4S)

5 1/2 S

6.30

10.55

6.38

approx. 24.3

For SI unit

Meter size

(inch)

1 (1S)

1-1/2 (1-1/2S)

2(2S)

3(3S)

4(4S)

Joint size

L1

D1

D2

Weight

(ISO2852)

(inch)

(inch)

(inch)

(lbs)

2 S

6.16

1.00

3.11

approx. 11.0

2 1/2 S

6.75

1.50

3.66

approx. 15.4

3 S

7.34

2.00

4.17

approx. 17.6

4 S

7.85

3.00

5.28

approx. 24.3

5 1/2 S

8.64

4.00

6.81

approx. 33.1

Meter size

Joint size

L1

L2

D1

Weight

(mm)

(ISO2852)

(mm)

(mm)

(mm)

(kg)

25 (1S)

2 S

110

179

73

approx. 4

40 (1 1/2S)

2 1/2 S

125

196

90

approx. 5

50 (2S)

3 S

140

210

104

approx. 6

80 (3S)

4 S

140

236

130

approx. 8

100 (4S)

5 1/2 S

160

268

162

approx. 11

Note: Tri-clamp® is available to use the same joint size instead of ISO2852 clamp except meter size 4" (100 mm).

Note: 1 inch = 25.4 mm

Figure 5. LF490/LF612 and LF494/LF612F

Flowmeters

(Ferrules and Clamps not attached)

For SI unit

Meter size

Joint size

L1

D1

D2

Weight

mm (inch)

(ISO2852)

(mm)

(mm)

(mm)

(kg)

25 (1S)

2 S

156.4

25.4

79

approx. 5

40(1 1/2S)

2 1/2 S

171.4

38.1

93

approx. 7

50 (2S)

3 S

186.4

50.8

106

approx. 8

80 (3S)

4 S

199.4

76.3

134

approx. 11.

100 (4S)

5 1/2 S

219.4

101.6

173

approx. 15

Note: Tri-clamp® is available to use the same joint size instead of ISO2852 clamp except meter size 4" (100 mm).

Note: 1 inch = 25.4 mm

Figure 6. LF490/LF612 and LF494/LF612F

Flowmeters

(Ferrules and Clamps attached)

6

Image 6
Contents Introduction Combined type Separate typeSpecifications Overall SpecificationsModel LF490 and LF494 Detectors Model LF610 and LF612 converters Surge protection Power supplyDimensions and Weights Cable connection ports Cable glandsInstallation Dimensions Combined typeDimensions Separate type Ferrule dimensions External Connections Combined type LF490/LF610 and LF494/LF610F flowmetersSeparate type LF490/LF612 and LF494/LF612F flowmeters Meter Size Wiring PrecautionsWiring Precautions Profibus To select the meter sizeStandard Flow Range Ordering InformationCalibration Range About establishment environmentSpecification Code Sanitary type detector LF490 Series Specification Code for converters Type Specification Code for Maintenance PartsThis Page Intentionally Blank TIC-LF494B ISO9001 and ISO14001 are certified