Toshiba TIC-LF494B manual Installation, Dimensions Combined type

Page 5

TIC-LF494B

Installation

Dimensions (Combined type)

Clamp connection

Unit : inch(mm)

8.86(225)

5.63(143)

1.42(36)

5.16(131)

 

(L2)

ØD1

L1

Note1: Clamp (Joint) size is different from meter size of LF490 and LF494. See the following table.

Note2: Cable glands are not provided for cFMus approved type.

Welding connection

 

 

 

Unit : inch(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.86(225)

 

1.42(36)

 

 

 

 

 

 

 

5.63(143)

 

 

 

 

 

 

 

 

Note1: L1 dimension is for the standard (Normal length) type ferrule.

Note2: See Figure 7 for Ferrule dimensions.

Note3: Cable glands are not provided for cFMus approved type.

For English unit

Meter size

Joint size

L1

L2

D1

Weight

(inch)

(ISO2852)

(inch)

(inch)

(inch)

(lbs)

1 (1S)

2 S

4.33

9.17

2.87

Approx. 11

1-1/2 (1-1/2S)

2 1/2 S

4.92

11.25

3.54

Approx. 13.2

2 (2S)

3 S

5.51

9.64

4.09

Approx. 15.4

3 (3S)

4 S

5.51

10.00

5.12

Approx. 19.8

4 (4S)

5 1/2 S

6.30

10.19

6.38

Approx. 26.5

For SI unit

Meter size

Joint size

L1

L2

D1

Weight

mm (inch)

(ISO2852)

(mm)

(mm)

(mm)

(kg)

25 (1S)

2 S

110

233

73

Approx. 5

40 (1 1/2S)

2 1/2 S

125

286

90

Approx. 6

50 (2S)

3 S

140

245

104

Approx. 7

80 (3S)

4 S

140

254

130

Approx. 9

100 (4S)

5 1/2 S

160

259

162

Approx. 12

Note: Tri-clamp® is available to use the same joint size instead of ISO2852 clamp except meter size 100 mm (4").

Note: 1 inch = 25.4 mm

Figure 3. LF490/LF610 and LF494/LF610F

Flowmeters

(Ferrules and Clamps not attached)

For English unit

Meter size

Joint size

L1

D1

D2

Weight

(inch)

(ISO2852)

(inch)

(inch)

(inch)

(lbs)

1

(1S)

2 S

6.16

1.00

3.11

Approx. 13.2

1-1/2

(1-1/2S)

2 1/2 S

6.75

1.50

3.66

Approx. 17.6

2

(2S)

3 S

7.34

2.00

4.17

Approx. 19.8

3

(3S)

4 S

7.85

3.00

5.28

Approx. 26.5

4

(4S)

5 1/2 S

8.64

4.00

6.81

Approx. 35.3

For SI unit

Meter size

Joint size

L1

D1

D2

Weight

mm (inch)

(ISO2852)

(mm)

(mm)

(mm)

(kg)

25 (1S)

2 S

156.4

25.4

79

Approx. 6

40(1 1/2S)

2 1/2 S

171.4

38.1

93

Approx. 8

50 (2S)

3 S

186.4

50.8

106

Approx. 9

80 (3S)

4 S

199.4

76.3

134

Approx. 12

100 (4S)

5 1/2 S

219.4

101.6

173

Approx. 16

Note: Tri-clamp® is available to use the same joint size instead of ISO2852 clamp except meter size 100 mm (4").

Note: 1 inch = 25.4 mm

Figure 4. LF490/LF610 and LF494/LF610F

Flowmeters

(Ferrules and Clamps attached)

5

Image 5
Contents Combined type Separate type IntroductionModel LF490 and LF494 Detectors SpecificationsOverall Specifications Model LF610 and LF612 converters Dimensions and Weights Power supplySurge protection Cable connection ports Cable glandsDimensions Combined type InstallationDimensions Separate type Ferrule dimensions Combined type LF490/LF610 and LF494/LF610F flowmeters External ConnectionsSeparate type LF490/LF612 and LF494/LF612F flowmeters Wiring Precautions Profibus Wiring PrecautionsMeter Size To select the meter sizeCalibration Range Ordering InformationStandard Flow Range About establishment environmentSpecification Code Sanitary type detector LF490 Series Type Specification Code for Maintenance Parts Specification Code for convertersThis Page Intentionally Blank TIC-LF494B ISO9001 and ISO14001 are certified