Air Filter
WARNING • Please carefully read the “Before using” section of this manual.
•Before caring, make sure the power switch is off and the power cable is not plugged in, then wait at least 45 minutes for the lamp to cool sufficiently.
•Use only the air filter of the specified type only.
•Do not use the projector with the air filter and filter cover removed. The use without the air filter could result in damage.
CAUTION • If the air filter becomes clogged by dust or the like, internal temperature rises and could cause malfunction. The power is automatically turned
off in order to prevent the projector from overheating internally.
Caring For The Air Filter
Cleaning the air filter every 100 hours using the FILTER MESSAGE function 42 is recommended. If the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible. Please check and clean the air filter periodically, even if there is no message. If the soiling will not come off the air filter, or it becomes damaged, then it needs to be replaced. Please replace the air filter as soon as possible.
memo When you replace the lamp, please replace also the air filter.
Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at
1least 45 minutes.
After making sure that the projector has cooled adequately, remove the filter cover
2and air filter.
Apply a vacuum cleaner to the top of the filter cover and
3the air filter to clean.
If the soiling will not come off the air filter, or it becomes damaged, it needs to be replaced.
If the air filter needs to be replaced, contact your dealer to prepare a new air filter. Tell the dealer your air filter type.
Hold the release buttons of the filter cover while pulling down it.
Insert the cleaned air filter or a new air filter, and replace
4the filter cover.
Turn on the projector power, and reset the filter timer.
5(1) While the projector running, press the MENU button to open the menu.
(2)Choose the “OPTION” on the menu using the / button, then press the button or ENTER button.
(3)Choose the “FILTER TIME” using the / button, then press the button or RESET button.
(4)Choose the “RESET” using the button.
Hold the release button of the air filter while pulling out it.
memo Incorrectly resetting of the filter timer (resetting
without replacement, or neglect of resetting after replacement) will result in incorrect message functions.