1. OUTLINE
NOTES:
1.5 Supply Specifications
1.To ensure print quality and print head life use only TOSHIBA TEC approved media.
2.When using a media roll of
3.Precaution for use of labels
When labels are used for printing, please only use outside wound labels. Use of an inside wound label causes a paper jam.
| Outside wound | Inside wound |
|
|
|
Label | Usable | Not usable |
|
|
|
Tag Paper | Usable | Usable |
|
|
|
1.5.2 Detection Area of the Transmissive Sensor
The Transmissive sensor is fixed and positioned at 6.35 mm right of the center of the media path. The Transmissive Sensor detects a gap between labels, as illustrated below.
|
| Area to be detected. | ||
Sensor position | ||||
|
|
|
| Label |
Min. 2 mm |
|
|
| Gap |
|
|
| ||
|
|
| ||
(Min. 6 mm: |
|
|
| Label |
cut mode) |
|
|
| |
|
|
|
| |
|
| Min. 8 mm |
Sensor position
Print side
Media feed direction
6.35mm
1.5.3 Detection Area of the Reflective Sensor
The figure below illustrates the relation between the head effective print width and media width. (for GS14 Type)
Out of print range |
|
|
|
| Print head element |
|
|
|
|
| Out of print range |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 mm | 108.0 mm±0.2mm |
| 2 mm | |||||||
|
|
|
|
| (Head Effective Print Range) |
|
|
|
|
|
|
112.0 mm (Max. media width)
(for TS14 Type)
Out of print range
3 mm
Out of print range
| Print head element |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 106.0 mm±0.2mm |
| 3 mm | ||
| (Head Effective Print Range) |
|
|
|
|
|
|
|
|
|
|
112.0 mm (Max. media width)