Toshiba VF-AS1 Series, RS485 Electric Power quantity, Forcibly braked Preliminary excitation

Page 47

E6581315

„Communication command2 (Communication Number : FA20, FA22)

This command is enabled only when the communication command is enabled. Set Bit 15 of Com- munication Command 1 (communication Number: FA00, FA04) to “1” (enable). When enabling the communication command by Communication Command 1, commands by communication can be given the priority irrespective of the setting of the command mode selection parameter (). However, if “48 (49): Forced switching from communication to local,” “56 (57): Forced continuous operation,” or “58 (59): Specified speed operationj” is set by input terminal function selection ( to ), the enabled command and frequency will be given the priority.

Once enabled, this setting will be enabled till disable is set (0 setting), power is turned off or is reset, or factory default setting () is selected.

Table 2 Data construction of communication command 2 (FA20, FA22)

Bit

Function

0

1

 

Remarks

 

 

 

 

Torque control

 

 

0

Control switching

Speed control

 

 

 

1

electric

power quantity

OFF

 

Reset

Electric

power quantity

reset

 

 

(FE76, FE77) reset

 

 

 

 

 

2

(Reserved)

 

 

 

3

Braking request (BC)

Normal

 

Forcibly braked

 

 

4

Preliminary excitation

Normal

 

Enabled

 

 

5

Brake release (B)

Brake applied

 

Brake released

 

 

6

Braking answer (BA)

Brake applied

 

Brake released

 

 

7

Maximum

deceleration

Normal

 

Enabled

 

 

forced stop

 

 

 

 

 

 

 

 

 

8

Acceleration/deceleration

 

 

 

Select

Acceleration/ de-

pattern selection 1

00: Acceleration/deceleration 1

celeration 1 - 4 by combi-

 

 

 

 

nation of two bits

 

 

 

01: Acceleration/deceleration 2

 

 

 

AD1: , 

 

Acceleration/deceleration

10: Acceleration/deceleration 3

9

AD2: , 

pattern selection 2

11: Acceleration/deceleration 4

 

AD3: , 

 

 

 

 

 

 

 

 

 

 

 

 

AD4: , 

10

V/Fswitching 1

00: V/F 1

 

 

 

 

01: V/F 2

 

 

Select V/F 1 - 4 by combi-

 

 

 

 

 

 

 

 

10: V/F 3

 

 

nation of two bits

11

V/Fswitching 2

 

 

11: V/F 4

 

 

 

 

 

 

 

 

 

 

 

12

Torque limit switching 1

00: Torque limit 1

 

 

 

 

01: Torque limit 2

 

 

Select torque limit 1 - 4 by

 

 

 

 

 

13

Torque limit switching 2

10: Torque limit 3

 

 

combination of two bits

11: Torque limit 4

 

 

 

 

 

 

 

 

 

 

 

14

Speed gain 1/2

Gain 1

 

Gain 2

Gain 1: , 

 

Gain 2: , 

 

 

 

 

 

 

15

(Reserved)

 

 

 

Note: The acceleration/deceleration change command ORs with Bit 6 of Communication number FA00 and FA04.

Set Bit 6 of FA00 and FA04 to “0” and use FA20 and FA22 when changing acceleration/deceleration in four types. Acceleration/deceleration 4 will be set when both Bit 8 of Communication number FA20 and FA22 (or Bit 6 of Communication number FA00 and FA04) and Bit 9 of Communication number FA20 and FA22 are set.

46

Image 47
Contents E6581315② Tosvert VF-AS1 Series RS485 Communication FunctionE6581315 Read first Safety precautionsContents Bit Word General outlines of the communication functionBIT15 BIT8BIT7 BIT0 BIT2 Data transmission specificationsMOUBUS-RTU Communication protocolAbout the handling of received frames Toshiba Inverter Protocol Binary mode 2FHData Data transmission format used in Ascii modeData transmission format INV-NO CMD28H Bytes Checksum area 5bytes BlankData SUM INV-NOData transmission format used in binary mode Sum 1 bytes Checksum not omissible 00H to FFH Command receivedReturned for the 57H W and 50H P commands Byte Bytes2FH Byte 4EH6EH Bytes NornTransmission format of Block Communication Page Bytes Blank Start Code INV-NO Block communication Computer Inverter CommandsDummy data is required for this command Reads the data with the specified communication numberRFE03077BCR RFE03CRPage Communication There is no communication number that matches Transmission errorsFormat error Data transmission format does not match Broadcast communication function VF-AS1 RFC90CR Examples of the use of communication commandsAscii mode Computer → Inverter Inverter → Computer From the computer H = 24d  trip statusExamples of Communication programs Goto =LENS$ For I=1 to LNext Input #1,B$Print #1,B$ 160 T=TIMER COUNT=TIMER-TIf Count 0 then T=TIMER Page Text2.Text = Text1.Text = End Sub End IfMSComm1.Output = Text2.Text & Chr13 End Sub Inverter number  MODBUS-RTU protocolCRC Read commandMODBUS-RTU transmission format Text size is 8 bytes fixed Inverter Write commandBlank Command 1 byte 5bytes Blank Command 1 byteEnd Return CRC Error codesCRC Generation Bit counter =Inter-drive communication Never use pin-7 P11 QWiring 4-wire RS485 communication) E6581315 QWiring 2-wire RS485 communicationPage Parameters relating to the slave side example =0.01% Proportional control of speed80.00Hz 40.00Hz Slave 100.00Hz 00%90.00Hz 45.00Hz Slave 100.00Hz1 00%INV-NO 1 byte Inverter number Transmission format for inter-drive communication0OFF Communication parametersMODBUS-RTU Inverter number Baud rate,  , Parity  INV INV → PC PC → INV „ Timer Time-out period Computer link PC → INV Master INV To SlaveUse this function for the following case Send waiting time , Free notes OFF Commands and monitoring from the computerCommunication commands commands from the computer PI OFFBraking answer BA Electric Power quantityForcibly braked Preliminary excitation Brake release BWire RS485 communication FA32 Output terminal no Specified data output „ Terminal board output data FA50„ FM analog output FA51 „ AM analog output FA52Unit 0.01% N·m Monitoring from the computerRFD00CR BIT15 „ Input terminal board status FD06, FE06RES Input terminal function selection 9 f119„ Output terminal board status FD07, FE07 ST=ON ST=OFF „ Inverter operating status 1 FD01, FE01„ Inverter operating status 3 FD49, FE49 „ Inverter operating status 2 FD42, FE42Preset speed operation „ Inverter operating command mode status FD45, FE45„ Inverter operating frequency mode status FD46, FE46 Bit Specifications Remarks „ Alarm information monitor FC91„ Cumulative operation time alarm monitor FE79 E6581315 Model Data „ Inverter model capacity code FB05Utilizing panel LEDs and keys by communication LED setting by communicationParameter Name Range Setting „ Block Communication Function for LED Display Blank Ascii LED display data code 00H-1FH are blankFA10=1 Key utilization by communicationFA10=0 Parameter data ROM EEPPage FE29 Input power Alarm codeFE02 Frequency command value 01Hz FE19 Torque commandFE84 Binary input value option Tion FE80 Cumulative power on timeE6581315 FD50 Light-load high-speed torque 01% ESC Appendix 1 Table of data codesCan SUBResponse time „ Data transmission time Appendix 2 Response timeVF-A7 Appendix 3 Compatibility with the communication functionAppendix 4 Troubleshooting Appendix 5 Connecting for RS485 communication TXB RXARXB TXA