Siemens IPC427C Internal ports, Compact Flash card interface, Port Position Connector Description

Page 111

Detailed descriptions

16.1 Internal components

16.1.4Internal ports

16.1.4.1Overview

Port

Position

Connector

Description

Compact Flash card

Internal

X3

50-pin CF socket, types I / II

(True IDE mode)

 

 

 

PCI -104

Internal

 

PCI interface

16.1.4.2

Compact Flash card interface

 

 

 

 

Compact Flash card interface, X3

 

 

 

 

 

 

 

 

Pin no.

Short description

Description

 

 

41

RESET#

Reset (output)

 

 

7

CS0#

Chip select 0(output)

 

 

32

CS1#

Chip select 1(output)

 

 

34

IORD#

I/O read (output)

 

 

35

IOWR#

I/O write (output)

 

 

20, 19, 18,

A0-A2

Address bit 0-2 (output)

 

 

17, 16, 15, 14, 12, 11, 10, 8

A3-A10

Address bit 3-10 (output) to ground

 

 

21, 22, 23, 2, 3, 4, 5, 6, 47, 48, 49,

D0-D15

Data bits 0-15 (in/out)

 

 

27, 28, 29, 30, 31

 

 

 

 

37

INTRQ

Interrupt request (input)

 

 

9

OE# /ATA SEL#

Enables True IDE mode

 

 

24

IOCS16#

I/O-chip select 16 (input)

 

 

39

CSEL#

Cable select (output)

 

 

42

IORDY

I/O ready (input)

 

 

46

PDIAG#

Passed diagnostic

 

 

45

DASP#

Drive active/slave present (not

 

 

 

 

connected)

 

 

26, 25

CD1#, CD2#

Card detect (not connected)

 

 

33, 40

VS1#, VS2#

Voltage sense (not connected)

 

 

43

DMARQ

DMA request (input)

 

 

44

DMACK#

DMA acknowledge (output)

 

 

36

WE#

Write enable

 

 

1, 50

GND

Ground

 

 

13, 38

VCC

+ 5V power

SIMATIC IPC427C

 

111

Operating Instructions, 04/2009, A5E02414743-01

 

Image 111
Contents Industrial PC Simatic IPC427C SimaticLegal information Table of contents Table of contents 105 Index AppendixESD guidelines List of abbreviationsPreface IntroductionGuideline to the Operating Instructions Contents format Table of ContentsSystem expansions Safety InstructionsGeneral safety instructions RepairsESD directives BatteryOverview DescriptionApplications Features Basic dataDrives and storage media Monitoring and safety functions Basic data PortsSoftware Operating systems Function Hard disk / SSD version Compact Flash card version Windows Embedded StandardActivation of Horm and creation of a Hiber File Design External DesignDevice components Pos Description Connection components Ports and power supplyOn/Off switch Position of on/off switch DescriptionOperator controls Status displays Status displaysMeaning Transport Application planningUnpacking and checking the delivery unit Unpacking the deviceNoting the device identification data COA Label Windows Embedded Standard Ambient and Environmental Conditions Permitted mounting positions Installing/mountingHorizontal preferred position Permitted temperatures Vertical Power supply at the topSuspended Upright mounting Permitted temperaturesMounting information Mounting the deviceMounting methods Mounting on DIN rails Mounting the device on DIN railsSteps for mounting on DIN rails Removing the device from the DIN rail Installing/mounting 5.4 Mounting on DIN railsRemoving mounting clamps from the device Installing brackets on the deviceSteps for installing the mounting brackets Mounting with mounting bracketsMounting examples Material Bore diameter Mounting/demounting the deviceMounting the vertical mounting bracket onto the device Upright mountingConnecting peripheral equipment ConnectingTo be noted before you connect the device Connecting the 24 V DC power supplyConnecting Steps for connecting the device to the 24 V DC power supplyProtective earth terminal Protective ground connectionUSB strain-relief Steps for connecting the USB strain-reliefCommissioning Factory stateConnections before commissioning Requirements Configuring the operating systemCommissioning Windows Embedded Standard Basic commissioning initial startupSwitch off the device Commissioning Windows XP Professional Switch off the device Commissioning other operating systems Commissioning guideAdditional information Integration into an Automation System EthernetRS232 Integration into an Automation System 8.1 Overview Simatic PC DiagMonitor software FunctionsMonitoring Functions Simatic PC DiagBase softwareTemperature monitoring Temperature monitoring/displayWD monitoring times Watchdog WDFunction Watchdog reactionsSet EWF Function CommandEnhanced Write Filter EWF Purpose and functionEwfmgr c -enable Special features for the use of Enhanced Write Filters EWFConfiguring Fbwf File Based Write Filter FbwfComparison between EWF and Fbwf Functions Sram buffer memory Battery monitoring Operation without monitor and keyboard Preparation Expansions and ConfigurationsOpen the device front panel ToolsSteps in opening the device front panel Open the deviceMemory expansion options Installing the memory moduleHow to remove a memory module Memory expansionInstalling a memory module Display of the current memory configurationHow to install a memory module Installing PCI-104 / PC/104 Plus modules Mounting PCI-104 or PC/104 Plus modules Mounting PCI-104 or PC/104-PlusmodulesSteps for mounting an expansion module Mounting additional PCI-104 or PC/104-Plusmodules Configuring/installing a PCI-104 or PC/104-PlusmoduleInstallation options for Compact Flash cards Installing/Removing Compact Flash CardsInstalling/removing an accessible Compact Flash card Opening the module receptacleSteps for opening the module receptacle Steps for installing a Compact Flash card Installing the Compact Flash cardSteps for removing a Compact Flash card Removing the Compact Flash cardSteps for removing a built-in Compact Flash card Installing/removing a built-in Compact Flash cardCarrying out repairs Maintenance and ServiceRemoving and Installing Hardware Components RepairsComponent Exchange interval Preventive maintenanceHow to remove a drive Replacing hard disk or SSD driveRemoving drives Installing a drive Tool Replace the backup batteryTo be noted before you replace the battery DisposalReplacing the battery Reconfiguring the Bios SetupSteps for replacing the battery Reinstalling the operating system General installation procedureWindows Embedded Standard Restoring the factory state Simatic IPC427C Windows XP Professional Setting up the operating system with the Recovery CDRestoring the factory state Maintenance and Service Reinstalling the operating system Setting up the operating system via the Recovery CD/DVD Booting with the Recovery CD/DVDPartition setup CDDRIVE\MUI Installation of the operating systemPartitioning the hard disk Setting up the partitions under Windows Embedded StandardPartitioning data media Partitioning the Compact Flash cardPartition Name Size File system Setting up the partitions under Windows XP ProfessionalInstalling drivers and software Driver installation under Windows Embedded StandardInstalling drivers and software Windows Installing updatesInstalling or updating application programs and drivers Updating the operating systemDownload from Bios update Performing a Bios updateCreating an image Data backupOn-screen error message Meaning / tip Alarm, error and system messagesBoot error messages On-screen error messagesAlarm, error and system messages 12.1 Boot error messages Troubleshooting/FAQs General problemsProblem Possible cause To correct or avoid error Problems when using modules of third-party manufacturers Safety Technical specificationsGeneral specifications General specificationsGeneral specifications Climatic Conditions Horizontal mounting positionVertical / portrait mounting position Drives / storage media General specifications Mech. Ambient conditionsSpecial Features MotherboardStatus displays on the device General specifications PortsMaximum power consumption of the auxiliary components Power requirements of the componentsCurrent consumption Power consumption At 24 V rated voltage 14.3 Integrated DC power supplyTechnical specifications Typical power consumptionOverview of the dimensional drawings Dimension drawingsDimensional drawing of the device Front view Dimension drawings of the deviceDimension drawings of the device with mounting brackets 100 101 Dimensional drawings of the device with expansion frames Dimensional drawing of the blinding plate Dimension drawing of the blanking plateDimension drawings Dimension drawing of the blanking plate Detailed descriptions Internal componentsOverview of internal components CPU Technical features of the motherboardBios Component Description Parameters PortPort Position Description External portsOverview 16.1.3.2 COM1/2DVI-I USB port, 4 channel high current Pin no 16.1.3.5 USBEthernet RJ45 connection Pin no Short description Description Input / outputCan bus ProfibusPort Position Connector Description Internal ports16.1.4.2 Compact Flash card interface PCI-104 or PCI part of the PC/104-Plus interface Pin no PCI-104 or PC/104-Plus interface PCI partOverview Bios SetupBios Setup program Changing the device configurationStarting Bios Setup Starting Bios SetupBios Setup menus Menu Description Menu layoutBy submenus Settings in the main menuMain menu Field MeaningSerial ATA Port 0, Serial ATA Port System time and dateBoot Options submenu Keyboard Features submenu Hardware Options submenu Entry MeaningPCI MPI / DP Advanced Menu Settings in the Advanced MenuIO Device Configuration submenu Ahci Sata Configuration submenuSecurity menu 12 Boot menu Boot menu13 Legacy submenu Legacy14 Boot Type Order field 129 15 Version menu example Version menuExit Menu Default Bios Setup entries Documenting your device configurationBios Setup default settings Legacy Boot Type Order IO device configurationSata Configuration BootVersion Simatic PC IPC427C ProfibusCPU ID Currently allocated system resources System resourcesSystem resources used by the BIOS/DOS PCI Interrupt LinesInterrupt Interrupt type Addresses 16.4 I/O Address AreasOverview of the internal module registers Overview of the internal module registersWatchdog trigger register read only, address 066h Meaning of the bitsWatchdog trigger register Can base address register write only, address 066h Output register LED 1 / 2 read/write, address 404Eh Output register LED 1 / 2 read/write address 404Eh BitsLED L2 Battery status tab read-only, address 50Fh Sram address register Sram address registerDeclaration of conformity Connecting peripheralsGuidelines and declarations EMC directiveSoftware License Agreement Approvals for the USA, Canada and Australia Product safetyCertificates and approvals DIN ISO 9001 certificate145 Service and support Training centerTechnical support Definition of ESD ESD GuidelinesBasic protective measures against electrostatic discharge Electrostatic chargingAbbreviation Term Meaning AbbreviationsDram FAQCRT CSAHtml HDAHDD HMIODD NCQNema NMISSD SO-DIMMSOM SPP154 Glossary Chipset Configuration filesConfiguration software CE markingDual Core CPU Device configurationDisc-at-once DriversGender changer ESD directiveFile Based Write Filter EWF FormattingInterface, multi-point ImageIntel VT InterfaceInterfaceLPT interface License keyLicense key disk Low-voltage directivePC card NEC ClassOperating system Packet writingPlug&Play PIC modePEG interface PixelPXE server Recovery CDReset Restore DVDSession at once Setup Bios SetupTroubleshooting Scsi interfaceWlan Warm restart166 Can IndexIndex Simatic S7 170
Related manuals
Manual 5 pages 54.7 Kb

IPC427C specifications

The Siemens IPC427C is a robust and versatile industrial PC designed to meet the demands of various applications in manufacturing, automation, and process control. This advanced system is tailored for use in harsh environments and is renowned for its high reliability and performance. One of the key features of the IPC427C is its compact design, allowing seamless integration into existing setups without consuming excessive space. This makes it particularly suitable for environments where space is at a premium.

The IPC427C utilizes powerful Intel processors, providing the necessary computational power to handle complex tasks and data processing. The system supports a range of Intel Core and Xeon processors, ensuring that users can select the configuration that best meets their performance requirements. Additionally, the IPC427C is equipped with an impressive amount of RAM, capable of supporting high-speed memory modules that enhance overall system performance.

Storage options in the IPC427C include both solid-state drives (SSD) and traditional hard disk drives (HDD), catering to various data storage needs. The solid-state drives offer faster data access speeds and higher durability compared to HDDs, making them ideal for critical applications. Users can also benefit from the flexibility in expansion options, as the IPC427C features multiple slots for add-on cards, enabling additional functionalities such as enhanced graphics capabilities or specialized communication interfaces.

Connectivity is another strong point of the IPC427C. Equipped with multiple USB ports, Ethernet connections, and serial interfaces, the system allows seamless integration with various peripherals and networks. This connectivity facilitates real-time data acquisition and communication, essential for modern industrial environments. The IPC427C also supports various protocols and standards, enhancing its compatibility with existing systems and software.

In terms of durability, the IPC427C is designed to withstand extreme temperatures, vibrations, and dust, making it suitable for industrial applications. Its fanless design reduces the likelihood of mechanical failures while ensuring silent operation. With its robust build quality, the IEC527C can operate continuously in demanding conditions, making it a reliable choice for a wide range of industrial applications.

Overall, the Siemens IPC427C stands out as a powerful and flexible industrial PC, combining advanced technologies and robust construction to provide reliable performance in challenging environments. Whether used in factory automation, machine control, or data processing, the IPC427C delivers efficiency and resilience, making it an essential component of modern industrial systems.