Dell PERC S300, (PERC) S100 manual Deleting Virtual Disks

Page 53

Table 6-3. Selection of Virtual Disk Sizes

To Create This

Perform This Task

Virtual Disk Size

 

 

 

 

< 2.199 TB

Use the <Page Up> or <Page Down> keys to select a size in large

 

increments

 

or

 

 

Use the up arrow or down arrow keys to select a size in small

 

increments.

 

Continue with "Creating Virtual Disks" on page 51.

 

 

> 2.199 TB

1 Press the <Page Up> or the up arrow key to increase the virtual

 

 

disk size.

 

2

At the maximum size, a dialog box appears in the User Input

 

 

field. It inquires if you want to limit the size of the virtual disk or

 

 

exceed the normal maximum size.

 

3

Press <Esc> to create a larger virtual disk.

 

4

Press the <Page Up> or the up arrow key, until the desired or

 

 

maximum available size has been attained.

 

5

Continue with "Creating Virtual Disks" on page 51.

NOTE: When physical disks of different capacities are used, the maximum size of the virtual disk is limited by the size of the physical disk with the smallest capacity.

NOTE: If you want to have a bootable virtual disk, make sure that INT 13 support is enabled on the controller, as described in "Controller Options" on page 58.

Deleting Virtual Disks

CAUTION: Although any virtual disk in the Virtual Disks field can be deleted, including the first-listed virtual disk in the field, do not delete the first- listed virtual disk. It may be the system’s bootable virtual disk. Deleting the bootable virtual disk erases the operating system and the controller drivers.

CAUTION: When a physical disk is removed from a system, the current PERC S100 adapter or PERC S300 adapter configuration information (metadata) remains on the disk. If the removed physical disk causes a virtual disk to fail, and the virtual disk is then deleted and a Rescan is performed, re-inserting the physical disk causes the PERC Virtual Disk Management utility to merge the re-inserted physical disk's

RAID Configuration and Management

53

Image 53
Contents User’s Guide February Contents Complete the Hardware Installation Installing the Perc S300 AdapterInstalling the Microsoft Windows Drivers Physical Disk-Related ErrorsIndustry Canada Notice Canada Only RAID Technology Understanding Disk ArraysContents Page Safety When Working Inside Your System Safety GeneralProtecting Against Electrostatic Discharge Page Introduction OverviewOverview Supported Platforms Physical disks RequirementsOverview Boot to it Summary of RAID Levels About RAIDDisk Mirroring RAID TerminologyDisk Striping Parity Data Spanned RAID LevelsExample of Distributed Parity RAID Description FeaturesGeneral Features Description Allows hot-swapping Physical disks, in the same virtual disk That supports hot-swapping DisksBackplane with hot-swap capability Features Migration during an OCE Virtual diskSpecifications RAID General Considerations Hardware InstallationBefore You Begin Installing the Perc S300 Adapter Installing a Perc S300 Adapter Connecting the Cables Connect Physical Disks to the Perc S300 Adapter Complete the Hardware InstallationHardware Installation Downloading the Controller Driver Media Installing the DriversInstalling the Microsoft Windows Drivers To Use Pre-Installation Requirements for the Controller DriversOperating System And Device Driver Media Sata Controller to either ATA Mode or Ahci Pre-Installation Procedures For The Controller Drivers Steps DVD, and so on, perform the following For Microsoft Windows Server 2008 and Windows Server 2008 R2 For Microsoft Windows Server For Microsoft Windows Server 2008 and Windows Server 2008 R2 Installing the Drivers Installing the Drivers Perc Virtual Disk Management Utility Operations Description RAID Configuration ManagementAccessing the Perc Virtual Disk Management Utility Perc Virtual Disk Management Text Colors Description Initializing Physical Disks Before You Begin Creating Virtual DisksRAID Configuration and Management Deleting Virtual Disks RAID Configuration and Management Swapping Two Virtual Disks Delete a Global Hot Spare Managing Global Hot SparesCreate a Global Hot Spare Viewing Virtual Disk Details Viewing Physical Disk DetailsController Options Controller Options Description How to OperateRescanning Disks Pause if Degraded Continuing to BootRAID Configuration and Management RAID Mode to ATA Mode TroubleshootingSystem Startup Problems Boot Mode, Boot Sequence Bios Bios Screen Corrective Action Lost This warning message appears when multiple virtual disks are Bios not Installed User Disabled INT13 Bios Load From virtual disk creation Virtual Disk-Related Errors A Virtual Disk is in a Failed State On the virtual diskRedundant virtual disk 12. Cannot Create a Global Hot Spare Select View Virtual Disk Details 14. a Dedicated Hot Spare Fails Physical Disk-Related ErrorsTroubleshooting Appendix a Controller SpecificationsRead, Write, and Cache Policy S300 adapterPhysical Disk Tasks Controller TasksTable A-3. Physical Disk Tasks Physical Disk Task Name Perc S300 adapterSupported RAID Levels Virtual Disk TasksTable A-4. Virtual Disk Tasks Virtual Disk Task Name AdapterVirtual Disk Specifications RAID Technology Understanding Disk Arrays and Virtual Disks Appendix BUnderstanding RAID Levels Appendix B Table B-2. Physical Disk States Definition Disk States Virtual and Physical DisksTable B-3. Virtual Disk States State Definition Failure StatesCreating Virtual Disks Future Expansion Table B-5. Minimum and Maximum Physical Disk ConfigurationsUnderstanding Physical Disks Physical Disk StatesRescanning Physical Disks for Changes in State Dedicated Hot SparesGlobal Hot Spares Regulatory Notices Appendix CFCC, Class a FCC Notice U.S. OnlyFCC, Class B CE Notice European Union Industry Canada Notice Canada OnlyIndustry Canada, Class a Industry Canada, Class BAppendix C CE Mark Notice Contacting Dell Appendix DAppendix D Index Index Index 100 101 102 103 Glossary104 105 106 Acronym for nanoseconds, one billionth of a second 107108 109 110