Dell R420xr owner manual System Profile Settings Screen

Page 23

Menu Item

Description

 

NOTE: Only Serial Device 2 can be used for SOL. To use console redirection

 

by SOL, configure the same port address for console redirection and the serial

 

device.

Failsafe Baud Rate

Displays the failsafe baud rate for console redirection. The BIOS attempts to

 

determine the baud rate automatically. This failsafe baud rate is used only if the

 

attempt fails and the value must not be changed. By default, the Failsafe Baud Rate

 

option is set to 115200.

Remote Terminal

Allows you to set the remote console terminal type. By default, the Remote

Type

Terminal Type option is set to VT 100/VT 220.

Redirection After

Allows you to enable or disable to the BIOS console redirection when the

Boot

operating system is loaded. By default, the Redirection After Boot option is set to

 

Enabled.

System Profile Settings Screen

Menu Item

Description

System Profile

Allows you to set the system profile. If you set the System Profile option to a mode

 

other than Custom, the BIOS automatically sets the rest of the options. You can

 

only change the rest of the options if the mode is set to Custom. By default, the

 

System Profile option is set to Performance Per Watt Optimized (DAPC). DAPC is

 

Dell Active Power Controller.

 

NOTE: The following parameters are available only when the System Profile is

 

set to Custom.

CPU Power

Allows you to set the CPU power management. By default, the CPU Power

Management

Management option is set to System DBPM (DAPC). DBPM is Demand-Based

 

Power Management.

Memory

Allows you to set the memory frequency. By default, the Memory Frequency

Frequency

option is set to Maximum Performance.

Turbo Boost

Allows you to enable or disable the processor to operate in turbo boost mode. By

 

default, the Turbo Boost option is set to Enabled.

C1E

Allows you to enable or disable the processor to switch to a minimum

 

performance state when it is idle. By default, the C1E option is set to Enabled.

C States

Allows you to enable or disable the processor to operate in all available power

 

states. By default, the C States option is set to Enabled.

Monitor/Mwait

Allows you to enable Monitor/Mwait instructions in the processor. By default, the

 

Monitor/Mwait option is set to Enabled for all system profiles, except Custom.

 

NOTE: This option can be disabled only if the C States option in Custom

 

mode is disabled.

 

NOTE: When C States is enabled in Custom mode, changing the Monitor/

 

Mwait setting does not impact system power/performance.

23

Image 23
Contents Dell PowerEdge R420xr Page Contents Installing System Components Troubleshooting Your System Getting Help 128 About Your System Front-Panel Features And IndicatorsLCD Panel Features LCD Panel Features Hard-Drive Indicator PatternsDrive-Status Condition Indicator Pattern RAID Only Back-Panel Features And IndicatorsGreen NIC Indicator CodesIndicator Indicator Code Link and activity Indicators are off Link indicator isFlashing amber Power Indicator CodesIndicator Indicator Code Power Indicator Condition Pattern Not litOther Information You May Need Power Indicator Condition PatternPower supply Using The System Setup and Boot Manager Using The System Setup Navigation Keys Choosing The System Boot ModeEntering System Setup Responding To Error MessagesSystem Bios Screen System Setup OptionsSystem Setup Main Screen System Information Screen Memory Settings ScreenProcessor Settings Screen Sata Settings Screen Integrated Devices Screen Boot Settings ScreenSerial Communications Screen System Profile Settings Screen System Security Screen Miscellaneous Settings System And Setup Password FeaturesPassword Or Uefi settings of your system Assigning a System And/Or Setup PasswordOperating With a Setup Password Enabled Deleting Or Changing An Existing Setup PasswordUsing Your System Password To Secure Your System Using The Boot Manager Navigation Keys Entering The Uefi Boot ManagerEmbedded System Management Boot Manager ScreenUefi Boot Menu Menu Item Description Select Uefi BootChanging The Thermal Settings IDRAC Settings UtilityEntering The iDRAC Settings Utility Front Bezel Optional Recommended ToolsRemoving the Bezel Filter Installing The Front BezelBezel Filter Optional Removing The Front BezelOpening And Closing The System Installing The Bezel FilterOpening The System Opening and Closing the System Closing The SystemInside the System Inside The SystemRemoving The Cooling Shroud Cooling ShroudRemoving and Installing the Cooling Shroud Installing The Cooling ShroudRdimm System MemoryMemory Socket Locations ProcessorMode-Specific Guidelines General Memory Module Installation GuidelinesMemory Optimized Independent Channel Mode Sample Memory ConfigurationsMT/s A1, B1 1600 MT/s 1333 A1, A2, B1, B2 Removing Memory Modules Memory module Memory-module socket ejectors Removing The Memory Module Installing Memory ModulesInstalling The Memory Module Removing a Hot-Swap Hard Drive Hard DrivesRemoving and Installing a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Installing a Hard Drive Into a Hard-Drive CarrierLocation of the Spare Hard-Drive Screws Cooling FansRemoving a Cooling Fan Removing and Installing a Cooling FanReplacing The Internal USB Key Installing a Cooling FanInternal USB Memory Key Optional Expansion Cards And Expansion-Card Risers Expansion Card Installation GuidelinesRemoving An Expansion Card Page Expansion card Expansion-card latch Riser touch points Removing Expansion-Card Risers 1 Installing An Expansion CardRemoving and Installing the Expansion-Card Riser Removing The iDRAC Enterprise Card Installing Expansion-Card Risers 1IDRAC Enterprise Card Optional Removing and Installing the iDRAC Enterprise Card Installing The iDRAC Enterprise CardReplacing An SD vFlash Card SD vFlash CardInternal Dual SD Module Removing The Internal Dual SD Module Removing and Installing the Internal Dual SD Module Installing The Internal Dual SD ModuleRemoving An Internal SD Card Installing An Internal SD CardInternal SD Card Integrated Storage Controller CardRemoving The Integrated Storage Controller Card Installing The Integrated Storage Controller Card Removing a Processor ProcessorsRemoving and Installing the Processor Heat Sink Removing and Installing a Processor Installing a ProcessorPage Removing a Power Supply Power SuppliesHot Spare Feature Replacing The System Battery System BatteryInstalling a Power Supply Hard-Drive Backplane Replacing the System BatteryRemoving The Hard-Drive Backplane Press the release tabs and slide the backplane upward Release tabs Hard-drive backplane Guide pins Chassis hooks Cabling Diagram Installing The Hard-Drive BackplaneRemoving The Control Panel Control Panel AssemblyRemoving The Control-Panel Module Installing The Control PanelRemoving and Installing the Control-Panel Module Installing The Control-Panel ModuleRemoving The Power Distribution Board Shroud Power Distribution Board ShroudRemoving and Installing the PDB Shroud Installing The Power Distribution Board ShroudRemoving The Power Distribution Board Power Distribution BoardRemoving and Installing the Power Distribution Board Installing The Power Distribution BoardRemoving The System Board System BoardRemoving and Installing the System Board Installing The System BoardPage Troubleshooting a USB Device Troubleshooting External ConnectionsTroubleshooting The Video Subsystem Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting System Memory Troubleshooting Cooling ProblemsTroubleshooting Cooling Fans Troubleshooting An Internal USB Key Troubleshooting a Hard Drive Troubleshooting An SD CardTroubleshooting a Storage Controller Troubleshooting Expansion Cards Troubleshooting Processors System Diagnostic Controls Dell Embedded System DiagnosticsWhen To Use The Embedded System Diagnostics Running The Embedded System DiagnosticsDisplayed if at least one event description is recorded System Board Jumper Settings Jumpers And ConnectorsFAN5 System Board ConnectorsDisabling a Forgotten Password Page Technical Specifications NIC For temperatures between 40 C and 45 C, de Page Page Removing LCD Messages System Error MessagesLCD Messages Viewing LCD MessagesAction Error CodeAMP0302 Message DetailsCPU0000 Message ASR0003 MessageBAT0002 Message BAT0017 MessageCPU0204 Message CPU0005 MessageCPU0010 Message CPU0023 MessageCPU0703 Message CPU0701 MessageCPU0702 Message FAN1201 Message CPU0704 MessageFAN0000 Message FAN0001 MessageMEM0000 Message HWC1001 MessageHWC2003 Message HWC2005 MessageMEM1205 Message MEM0007 MessageMEM0701 Message MEM0702 MessagePCI1308 Message MEM8000 MessagePCI1302 Message PCI1304 MessagePDR0001 Message PCI1342 MessagePCI1348 Message PCI1360 MessagePSU0002 Message PST0128 MessagePST0129 Message PSU0001 MessagePSU0033 Message PSU0016 MessagePSU0031 Message PSU0032 MessagePSU0037 Message PSU0034 MessagePSU0035 Message PSU0036 MessagePWR1005 Message PSU1201 MessagePSU1204 Message PWR1004 MessageRFM2001 Message RFM1008 MessageRFM1014 Message RFM1201 MessageSEL0006 Message RFM2006 MessageSEC0031 Message SEC0033 MessageTMP0120 Message SEL1204 MessageTMP0118 Message TMP0119 MessageVLT0204 Message Diagnostic MessagesAlert Messages Documentation Feedback Locating Your System Service TagContacting Dell