Dell R420xr owner manual Installing The Power Distribution Board Shroud

Page 83

3.Lift the power distribution board (PDB) shroud away from the system.

Figure 39. Removing and Installing the PDB Shroud

1. PDB shroud tabs (2)

2. PDB shroud

3.arrow marked on the PDB shroud

Installing The Power Distribution Board Shroud

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE: For proper seating of the power distribution shroud in the chassis, ensure that the cables inside the system are routed through the cable securing latch.

1.Align the PDB shroud with the numbered fan bay and the arrow as the guide.

2.Lower the PDB shroud into the chassis so that the two tabs on the PDB shroud rest on the cooling fan bracket.

When firmly seated, the PDB shroud aligns flush with the power supply unit bracket and the arrow marked on the shroud aligns with the arrow on the power supply bracket.

3.Close the system.

4.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

83

Image 83
Contents Dell PowerEdge R420xr Page Contents Installing System Components Troubleshooting Your System Getting Help 128 About Your System Front-Panel Features And IndicatorsLCD Panel Features LCD Panel Features Hard-Drive Indicator PatternsDrive-Status Condition Indicator Pattern RAID Only Back-Panel Features And IndicatorsGreen NIC Indicator CodesIndicator Indicator Code Link and activity Indicators are off Link indicator isFlashing amber Power Indicator CodesIndicator Indicator Code Power Indicator Condition Pattern Not litOther Information You May Need Power Indicator Condition PatternPower supply Using The System Setup and Boot Manager Using The System Setup Navigation Keys Choosing The System Boot ModeEntering System Setup Responding To Error MessagesSystem Bios Screen System Setup OptionsSystem Setup Main Screen System Information Screen Memory Settings ScreenProcessor Settings Screen Sata Settings Screen Integrated Devices Screen Boot Settings ScreenSerial Communications Screen System Profile Settings Screen System Security Screen Miscellaneous Settings System And Setup Password FeaturesPassword Or Uefi settings of your system Assigning a System And/Or Setup PasswordOperating With a Setup Password Enabled Deleting Or Changing An Existing Setup PasswordUsing Your System Password To Secure Your System Using The Boot Manager Navigation Keys Entering The Uefi Boot ManagerEmbedded System Management Boot Manager ScreenUefi Boot Menu Menu Item Description Select Uefi BootChanging The Thermal Settings IDRAC Settings UtilityEntering The iDRAC Settings Utility Front Bezel Optional Recommended ToolsRemoving the Bezel Filter Installing The Front BezelBezel Filter Optional Removing The Front BezelOpening And Closing The System Installing The Bezel FilterOpening The System Opening and Closing the System Closing The SystemInside the System Inside The SystemRemoving The Cooling Shroud Cooling ShroudRemoving and Installing the Cooling Shroud Installing The Cooling ShroudRdimm System MemoryMemory Socket Locations ProcessorMode-Specific Guidelines General Memory Module Installation GuidelinesMemory Optimized Independent Channel Mode Sample Memory ConfigurationsMT/s A1, B1 1600 MT/s 1333 A1, A2, B1, B2 Removing Memory Modules Memory module Memory-module socket ejectors Removing The Memory Module Installing Memory ModulesInstalling The Memory Module Removing a Hot-Swap Hard Drive Hard DrivesRemoving and Installing a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Installing a Hard Drive Into a Hard-Drive CarrierLocation of the Spare Hard-Drive Screws Cooling FansRemoving a Cooling Fan Removing and Installing a Cooling FanReplacing The Internal USB Key Installing a Cooling FanInternal USB Memory Key Optional Expansion Cards And Expansion-Card Risers Expansion Card Installation GuidelinesRemoving An Expansion Card Page Expansion card Expansion-card latch Riser touch points Removing Expansion-Card Risers 1 Installing An Expansion CardRemoving and Installing the Expansion-Card Riser Removing The iDRAC Enterprise Card Installing Expansion-Card Risers 1IDRAC Enterprise Card Optional Removing and Installing the iDRAC Enterprise Card Installing The iDRAC Enterprise CardReplacing An SD vFlash Card SD vFlash CardInternal Dual SD Module Removing The Internal Dual SD Module Removing and Installing the Internal Dual SD Module Installing The Internal Dual SD ModuleRemoving An Internal SD Card Installing An Internal SD CardInternal SD Card Integrated Storage Controller CardRemoving The Integrated Storage Controller Card Installing The Integrated Storage Controller Card Removing a Processor ProcessorsRemoving and Installing the Processor Heat Sink Removing and Installing a Processor Installing a ProcessorPage Removing a Power Supply Power SuppliesHot Spare Feature Replacing The System Battery System BatteryInstalling a Power Supply Hard-Drive Backplane Replacing the System BatteryRemoving The Hard-Drive Backplane Press the release tabs and slide the backplane upward Release tabs Hard-drive backplane Guide pins Chassis hooks Cabling Diagram Installing The Hard-Drive BackplaneRemoving The Control Panel Control Panel AssemblyRemoving The Control-Panel Module Installing The Control PanelRemoving and Installing the Control-Panel Module Installing The Control-Panel ModuleRemoving The Power Distribution Board Shroud Power Distribution Board ShroudRemoving and Installing the PDB Shroud Installing The Power Distribution Board ShroudRemoving The Power Distribution Board Power Distribution BoardRemoving and Installing the Power Distribution Board Installing The Power Distribution BoardRemoving The System Board System BoardRemoving and Installing the System Board Installing The System BoardPage Troubleshooting a USB Device Troubleshooting External ConnectionsTroubleshooting The Video Subsystem Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting System Memory Troubleshooting Cooling ProblemsTroubleshooting Cooling Fans Troubleshooting An Internal USB Key Troubleshooting a Hard Drive Troubleshooting An SD CardTroubleshooting a Storage Controller Troubleshooting Expansion Cards Troubleshooting Processors System Diagnostic Controls Dell Embedded System DiagnosticsWhen To Use The Embedded System Diagnostics Running The Embedded System DiagnosticsDisplayed if at least one event description is recorded System Board Jumper Settings Jumpers And ConnectorsFAN5 System Board ConnectorsDisabling a Forgotten Password Page Technical Specifications NIC For temperatures between 40 C and 45 C, de Page Page Removing LCD Messages System Error MessagesLCD Messages Viewing LCD MessagesAction Error CodeAMP0302 Message DetailsCPU0000 Message ASR0003 MessageBAT0002 Message BAT0017 MessageCPU0204 Message CPU0005 MessageCPU0010 Message CPU0023 MessageCPU0703 Message CPU0701 MessageCPU0702 Message FAN1201 Message CPU0704 MessageFAN0000 Message FAN0001 MessageMEM0000 Message HWC1001 MessageHWC2003 Message HWC2005 MessageMEM1205 Message MEM0007 MessageMEM0701 Message MEM0702 MessagePCI1308 Message MEM8000 MessagePCI1302 Message PCI1304 MessagePDR0001 Message PCI1342 MessagePCI1348 Message PCI1360 MessagePSU0002 Message PST0128 MessagePST0129 Message PSU0001 MessagePSU0033 Message PSU0016 MessagePSU0031 Message PSU0032 MessagePSU0037 Message PSU0034 MessagePSU0035 Message PSU0036 MessagePWR1005 Message PSU1201 MessagePSU1204 Message PWR1004 MessageRFM2001 Message RFM1008 MessageRFM1014 Message RFM1201 MessageSEL0006 Message RFM2006 MessageSEC0031 Message SEC0033 MessageTMP0120 Message SEL1204 MessageTMP0118 Message TMP0119 MessageVLT0204 Message Diagnostic MessagesAlert Messages Documentation Feedback Locating Your System Service TagContacting Dell