Dell 2900 Power Distribution Board Service-Only Procedure, Removing the Power Distribution Board

Page 110

3Reinstall the CPU processor(s). See "Replacing a Processor" on page 89.

4Reinstall the memory modules. See "Installing Memory Modules" on page 85.

5Reconnect all cables to the connectors on the front edge of the system board.

6Reinstall the TOE key, if applicable. See Figure 6-2.

7Reinstall the expansion-bay bracket:

a Align the expansion-bay bracket with the tabs on the system board and the chassis wall and then carefully push the bracket into the tabs.

b Gently push the bracket toward the back of the chassis until the latch on the left side of the bracket engages.

8Install all expansion cards. See "Installing an Expansion Card" on page 68.

9Reinstall the SAS controller daughter card. See "SAS Controller Daughter Card" on page 96.

10If a RAC card is present, attach the cables to the RAC connectors on the system board. See "Installing a RAC Card" on page 87.

11Reinstall the center and rear fan brackets. See "Replacing the Center Fan Bracket" on page 81 and "Replacing the Back Fan Bracket" on page 82.

12Install the memory cooling shroud. See "Installing the Cooling Shroud" on page 81.

NOTICE: Never operate your system with the memory cooling shroud removed. Overheating of the system can develop quickly resulting in a shutdown of the system and the loss of data.

13Install all of the cooling fans. See "Removing and Installing a Fan" on page 65

14Reconnect all cables to the expansion cards.

15Close the system. See "Closing the System" on page 53.

16Reconnect all cables to the front and rear of the system.

17Reconnect the system to the power source and turn on the system and attached peripherals.

18Replace the front bezel, if removed.

Power Distribution Board (Service-Only Procedure)

Removing the Power Distribution Board

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

110

Installing System Components

Image 110
Contents Dell PowerEdge 2900 Systems W . d e l l . c o m s u p p o r t . d e l l . c o mDecember Contents Installing System Components Baseboard Management Controller ConfigurationGeneral Memory Module Installation Guidelines Removing or Installing the Cooling Shroud FanInstalling the Diskette Drive Into the Drive Carrier 105 Cabling the SAS Controller Non-RAID101 109Using Server Administrator Diagnostics 135 Troubleshooting System Cooling Problems 123Troubleshooting an External Scsi Tape Drive 128 116139 Returning Items for Warranty Repair or Credit 149137 141About Your System About Your SystemSystem Orientation Other Information You May NeedAccessing System Features During Startup Front-Panel Features and Indicators USB connectors LCD lights amber when the system needsWhether the system has been powered on Tape backup unitHard-Drive Indicator Codes Amber About Your SystemAbout Your System System status indicator Power supply 2 optional Back-Panel Features and IndicatorsConnecting External Devices Connector Power supplyIndicator Function Power Indicator CodesRedundant Power Supply Indicators Green indicates that the power supply is operationalNIC Indicator Codes LCD Status MessagesE1116 Temp Memory E1000 FAILSAFE, CallSupport E1114 Temp Ambient E1210 Cmos BattE1418 CPU # Presence E1410E1414 CPU # Thermtrip E141C CPU MismatchE1614 PS # Status E1422 CPU Machine ChkE1610 PS # Missing E1618 PS # PredictivePCI Serr Slot # E1810 HDD ## FaultE1712 E1714 Unknown ErrE1A14 SAS Cable a E2011 Mem Config ErrE2013 Shadow Bios Fail E1A15 SAS Cable BE2019 Parity Error E2017 Timer FailE2018 Prog Timer E201F Drac ConfigFully Buffered Dimm FBD Removing LCD Status Messages Solving Problems Described by LCD Status MessagesSystem Messages Attempting to update Disabled! MemoryConfiguration does not Remote ConfigurationError Remote Access Been disabled by BiosDiskette subsystem reset Dual-rank Dimm paired withConfiguration, Resource FBD training errorDisabled Branch Manufacturing modeNo timer tick Interrupt No boot device availableNo boot sector on hard drive Northbound merge errorError PCI Bios failed to installPlug & Play Configuration Read fault Requested sector not foundUpdate loaded for Please run Setup programTimer chip counter Following Dimm pair isDiagnostics Messages Alert MessagesAbout Your System Using the System Setup Program Entering the System Setup ProgramResponding to Error Messages Main Screen System Setup OptionsUsing the System Setup Program Logical Processor option. See Table System memory test option, and redundant memory statusCPU Information Network System Setup Program Options Description Sata PortBoot Sequence From external devicesCPU Information Screens Integrated Devices Screen Serial Communication Screen System Security ScreenExit Screen System and Setup Password Features Using the System PasswordUsing the System Setup Program Using the Setup Password Deleting or Changing an Existing System PasswordSee Disabling a Forgotten Password on Disabling a Forgotten PasswordBaseboard Management Controller Configuration Entering the BMC Setup Module BMC Setup Module OptionsUsing the System Setup Program Installing System Components Recommended ToolsOpening and Closing the System Removing the BezelInstalling and Removing the Optional Bezel Tower Keylock Bezel latch Installing System ComponentsPeripheral bay panel Installing the Peripheral Bay Panel Tower OnlyRemoving the Peripheral Bay Panel Tower Only Bay panel Bezel inside view Tab slotClosing the System Installing the BezelOpening the System Hot-Plug Hard Drives Cover latchBefore You Begin Hard-Drive Bay Numbers Rack 1x2 flex bay hard drivesRemoving a Drive Blank Installing a Drive BlankInstalling a Hot-Plug Hard Drive Removing a Hot-Plug Hard DriveInstalling a Hot-Plug Hard Drive Removing a Hard Drive From a Hard-Drive Carrier Installing a SAS Hard Drive Into a SATAu Drive CarrierReplacing a Hard-Drive Carrier Installing a Sata Hard Drive Into a Sata Drive Carrier Sata hard drive Sata hard-drive Hole labels Installing System Components Power Supplies Removing a Power SupplyInstalling a Power Supply Power supply Handle Tab Power supply blank ScrewFans Removing the Power Supply BlankInstalling the Power Supply Blank Removing and Installing a Fan Processor fan FAN2 Processor fan FAN3Removing or Installing the Cooling Shroud Fan Fan connector on system boardFan bracket latch Installing System Components Installing an Expansion Card Expansion Cards15. Installing and Removing Expansion Cards Card-edge guide Expansion cardRemoving an Expansion Card Internal Scsi Tape Backup UnitRemoving an Internal Scsi Tape Backup Unit Installing an Internal Scsi Tape Backup Unit Peripheral bay Optical driveInstalling System Components Removing an Optical Drive Installing an Optical DriveOptical Drive Diskette Drive Removing the Diskette DriveDiskette drive power cable Installing the Diskette Drive Into the Drive Carrier Installing the Diskette DriveSystem Battery Replacing the System BatteryNegative side of connector Cooling Shroud Removing the Cooling ShroudCooling shroud latch right Removing the Center Fan Bracket Installing the Cooling ShroudFan Brackets Replacing the Center Fan BracketReplacing the Back Fan Bracket MemoryRemoving the Back Fan Bracket 21. Dimm Sockets Installing System Components Memory Sparing Support General Memory Module Installation GuidelinesNon-Optimal Memory Configurations Installing Memory Modules Memory Mirroring SupportMemory module socket ejectors Installing a RAC Card Removing Memory Modules23. Installing a RAC Card Notch in card edge Back standoff RAC card RAC connector Expansion-bay bracketReplacing a Processor Activating the Integrated NIC TOEMicroprocessor 24. Installing and Removing the Heat Sink Heat sink ZIF socket Processor Installing System Components Removing the 1x8 SAS Backplane Board Installing the 1x8 SAS Backplane Board1x8 SAS Backplane Board Optional 1x2 Flex Bay Drive Bracket Removing the 1x2 Flex Bay Drive BracketInstalling the 1x2 Flex Bay Drive Bracket 26. Installing and Removing the Flex Bay Drive BracketReplacing the SAS RAID Controller Daughter Card Battery SAS Controller Daughter CardRemoving the SAS Controller Daughter Card RAID battery cableCable RAID battery Connector release tab Battery bay CardOnly out to 1x8 backplane Sasb connector or Sasbin connector Cable Requirements Installing the SAS Controller Daughter CardCabling the SAS Backplane Boards Cabling the SAS Controller Non-RAIDSasa connector 100Cabling the SAS RAID Controller 101102 SAS1 connectorCard Dimm not shown 1x8 SAS backplane Sasb connector 103 104 Removing the Control Panel Assembly Configuring the Boot DriveControl Panel Assembly Service-Only Procedure 105Installing the Control Panel Assembly Display module107 System Board Service-Only ProcedureRemoving the System Board Installing System Components Installing the System Board 109110 Power Distribution Board Service-Only ProcedureRemoving the Power Distribution Board 111 Installing the Power Distribution Board 113 114 115 Safety First-For You and Your SystemStart-Up Routine Checking the Equipment Troubleshooting IRQ Assignment ConflictsTroubleshooting External Connections 116Monitor is not working properly Video memory is faulty Troubleshooting the Video SubsystemTroubleshooting the Keyboard ProblemTroubleshooting Basic I/O Functions Troubleshooting the Mouse119 Troubleshooting a Serial I/O DeviceTroubleshooting a USB Device NIC cannot communicate with network Troubleshooting a NICTroubleshooting a Wet System Liquid spilled on the system Excessive humidity121 Troubleshooting a Damaged SystemSystem was dropped or damaged Troubleshooting the System Battery Troubleshooting Power Supplies123 Troubleshooting System Cooling ProblemsTroubleshooting a Fan Troubleshooting System Memory 125 Troubleshooting a Diskette Drive Error message indicates a diskette drive problemTroubleshooting an Optical Drive 127Troubleshooting an External Scsi Tape Drive Troubleshooting a Hard Drive 129Troubleshooting a SAS or SAS RAID Controller Daughter Card Troubleshooting Expansion Cards 131Action Troubleshooting the Microprocessors 133Troubleshooting Your System When to Use the System Diagnostics Using Server Administrator DiagnosticsSystem Diagnostics Features 135Using the Custom Test Options Running the System DiagnosticsSystem Diagnostics Testing Options Selecting Devices for Testing137 Selecting Diagnostics OptionsViewing Information and Results 138 139 Jumpers and ConnectorsSystem Board Jumpers System boot BootConfiguration settings in Nvram are cleared at next 140System Board Connectors 141SAS Backplane Connectors 143 X2 SAS Backplane Connectors Power connector Sasbin connector 145 146 147 Online ServicesTechnical Assistance Getting HelpTechnical Support Service AutoTech ServiceAutomated Order-Status Service Electronic Quote Service149 Before You Call 150151 Contacting Dell 152153 154 155 156 157 158 159 160 161 162 163 Fax SwitchboardCustomer Service Fax Country Code Technical Support for all other Dell products164 165 Country Code Precision Technical Support PowerApp, PowerEdge 166167 168 BTU British thermal unit 169Amperes AC Alternating current Celsius170 Cm Centimeters Cmos Complementary metal-oxide semiconductorFBD Fully buffered Dimm 171Fahrenheit Kilo Kb Kilobits 1024 bits Glossary172 LVD Low voltage differential Meters MA Milliamperes173 174 TCP/IP Transmission Control Protocol/Internet Protocol175 Volts VAC Volts alternating current VDC Volts direct current176 177 IndexSAS backplane 1x8, 93 SAS controller daughter Installing Sata in a SATAu drive carrierCard SAS hard drive in a SATAu drive carrierPost 179Index 181 182
Related manuals
Manual 2 pages 61.02 Kb