Mackie SP1200 user service Upgrading the Software, Using the SPLinker Sound Palette Controller

Page 22

ADDRESS switch #6 in the Master position (up), and the other unit in the Slave position (down).

In this way, you can have one Remote control operate both amplifiers that are assigned to the same zone.

Note: The microprocessor polls the AMP ADDRESS switch when it initializes at power-up. If a change is made to the AMP ADDRESS switch, turn the SP1200 off for five seconds, then turn it back on again for the new settings to take effect.

Using the SPLinker Sound Palette Controller

The RS485 connection can also be used to connect the SP1200 to a computer loaded with the SPLinker software application. The PC-compatible computer must have an RS485 port to properly connect to the SP1200. It may be necessary to install an RS485 interface card, or use an RS232 port with an RS232-to-RS485 converter.

The SPLinker is a PC-based graphical interface to provide real-time monitoring and control (for up to 32 zones when used with SP2400s). It provides individual program source selection and volume control for each zone. Select boxes are located at the bottom of each zone for selecting multiple zones. All selected zones can then be modified at the same time in the Multiple settings box located on the right-hand side of the screen.

Using a 3rd Party Control System

The RS485 connection can also be used to interface with common third-party control systems. Contact the third-party provider or Mackie Industrial Technical Support to determine if your control system is compatible with the SP1200.

Upgrading the Software

From time to time, Mackie Industrial will release upgrades for the internal operating software in the SP1200. This can be downloaded from our website (www.mackieindustrial.com) to a PC-compatible computer. Use the serial port on the computer to connect to internal connector on the SP1200's CPU board to transfer the data to the on-board flash memory. Instructions will be provided when upgrades are available.

SP1200 – 22

Image 22
Contents OL on PowerOutput Suitable For Class 2 Wiring Paging MICSafety Instructions Table of ContentsKey Features IntroductionFront Panel Features Rear Panel FeaturesDo not Open Avis Risque DE Choc Electrique NE PAS Ouvrir LOW High PriorityRisk of Fire Replace with Same Type Fuse and Rating Output SuitableApplication Diagrams InstallationTypical Monaural Application Local Inputs Multiple SP1200s-Multiple Zones-Shared SourcesProgram Inputs Paging MIC Paging Program EQExpansion Expansion OUT Expansion with Local MicExpansion Expansion OUT Output Record Room Combining-ZonesPort Comm Remote BUS Outputs DirectTips on Installing and Using the SP1200-Plan Ahead ApplicationsConnecting the Speakers Connecting the Program SourcesConnecting the Microphones ConnectionsConnecting the Expansion Bus Connecting the Remote BusConnecting the RS485 Serial Port Internal SettingsBus Assign 70V/100V/8 Ohm Settings EQ BypassThermal Considerations AC Power ConsiderationsVoltage Conversion Operation External Switch SettingsInternal Switch and Jumper Settings SP1200 Quick StartRemote Local MIC/LINE InputAmbient MIC Input RS485Input 1 and the Direct Output Using InputsUsing the 3-Band EQ Input 4 PrioritySetting the Gain Using the Paging MicUsing the Ambient Mic Setting the VOX ThresholdUsing the Local MIC/LINE Input Ambient Mic Calibration and PlacementUsing the RS485 Connection Using the PRE OUT/AMP ConnectionsUsing the Remote Connection Zone a OutputUsing a 3rd Party Control System Using the SPLinker Sound Palette ControllerUpgrading the Software Specifications SP1200 Block DiagramSP1200 Specifications Power Amplifier SectionService Information Appendix a Default SettingsPress 2 on Power Up Ambient Mic Preamp Metering Appendix B Button Modes SP1200 Button ModesAppendix C Voltage Conversion Mackie Industrial