Mackie SP1200 user service Using the Local MIC/LINE Input, Ambient Mic Calibration and Placement

Page 20

Ambient Mic Calibration and Placement

1.Connect the MT-3100 (or other microphone) to the AMBIENT MIC connector on the rear panel. Make sure the ambient mic switch is on (AMP ADDRESS switch #8 up). Locate the ambient mic in an appropriate position to pick up the ambient noise in the room. It can be mounted on the ceiling or on a wall. Avoid placing the ambient mic close to the speaker over which the announcement is being made. Keep the ambient mic away from a constant noise source, such as a refrigerator or other mechanical device that emits a continuous noise. The best placement is where the mic can pick up an average representation of the ambient noise level in the room.

Note: Each zone or channel must be calibrated individually.

2.Turn off the SP1200, then turn it back on again while pressing and holding the Input 2 button. This causes the ambient mic preamp level to appear on the meter.

3.Establish the highest noise level that you would expect to have in the room using a pink or white noise source, or a music source. Input 1 is operational in this mode to use as a music source, if desired.

4.The ambient mic preamp gain trim is located just above the ambient mic connector on the rear panel, through the unmarked hole. Adjust it with a non- conductive alignment tool until all the green LEDs on the meter are lit. Insure that no yellow or red LEDs are lit, which runs the risk of clipping the ambient mic preamp or ADC.

5.Press the “OFF” button when finished to return to normal operation.

Paging Microphone Calibration Procedure (When Used with Ambient Mic)

1.Perform the “Ambient Microphone Calibration Procedure” described above.

2.Switch the ambient mic OFF (AMP ADDRESS switch #8 down).

3.Adjust the MASTER VOLUME control by pressing the Up/Down buttons so the meter indicates a level at the “0” mark.

4.Adjust the PAGING MIC GAIN control as high as it will go before feedback occurs while speaking into the paging microphone.

5.Switch the ambient mic on (AMP ADDRESS switch #8 up).

6.Turn off the SP1200, then turn it back on again while pressing and holding the “3” button.

7.Release the Input 3 button after a few seconds and the third LED starts flashing slowly.

SP1200 – 20

8.Use the front panel Up/Down buttons to set the lower level of the paging mic (how loud it is with very quiet background noise). It should be loud enough to be heard clearly throughout the coverage area.

9.Press the “OFF” button and the level is stored. The third LED starts flashing faster.

10.Use the front panel Up/Down buttons to set the upper level of the paging mic (how loud it is with very loud background noise). As a general rule, set this level as high as it will go before feedback (at the "0" mark if steps 3-4 above were followed).

11.Press the Input 3 button when finished to store the level and return to normal operation.

12.Verify that the paging microphone’s volume is sufficient to be heard over the background noise in the room.

Note: For best results, with the background noise level at a minimum, the paging mic volume should be approximately the same as the music volume.

13.If the paging microphone is not loud enough to be heard over the background noise, verify that the ambient mic is properly placed to pick up an accurate representation of the background noise. If it is, it may be necessary to readjust the lower and upper levels for the paging mic gain (steps 6-11).

Using the Local MIC/LINE INPUT

The MIC/LINE INPUT A is provided for the zone to connect a microphone for a speaker in a conference room, or similar sound reinforcement applications. If the local mic is a condenser mic, move the PHANTOM switches to the down position.

Setting the GAIN

When a microphone is connected directly to the MIC/LINE INPUT, the GAIN +40 dB switch should be set in the down position (for a mic-level signal).

When the mic is going through an external mixer, sending a line-level signal to the input, move the GAIN +40 dB switch to the up position (for a line- level signal only).

Press the OFF button to select the MIC/LINE INPUT. Adjust the MASTER VOLUME control by pressing the up/down buttons so the meter indicates a level at the “0” mark. With all music sources off, speak into the mic with a normal voice. Adjust the MIC/LINE INPUT GAIN control with a non-conductive alignment tool so that the meter indication is near the "0" mark. This provides the best signal-to-noise ratio for the mic and insures that its relative volume will be equivalent to the program sources.

Image 20
Contents Power Output Suitable For Class 2 WiringOL on Paging MICSafety Instructions Table of ContentsKey Features IntroductionFront Panel Features Rear Panel FeaturesLOW High Priority Risk of Fire Replace with Same Type Fuse and RatingDo not Open Avis Risque DE Choc Electrique NE PAS Ouvrir Output SuitableTypical Monaural Application InstallationApplication Diagrams Multiple SP1200s-Multiple Zones-Shared Sources Program Inputs Paging MICLocal Inputs Paging Program EQExpansion Expansion OUT Output Expansion with Local MicExpansion Expansion OUT Room Combining-Zones Port Comm Remote BUS OutputsRecord DirectTips on Installing and Using the SP1200-Plan Ahead ApplicationsConnecting the Program Sources Connecting the MicrophonesConnecting the Speakers ConnectionsConnecting the Expansion Bus Connecting the Remote BusBus Assign Internal SettingsConnecting the RS485 Serial Port 70V/100V/8 Ohm Settings EQ BypassVoltage Conversion AC Power ConsiderationsThermal Considerations External Switch Settings Internal Switch and Jumper SettingsOperation SP1200 Quick StartLocal MIC/LINE Input Ambient MIC InputRemote RS485Using Inputs Using the 3-Band EQInput 1 and the Direct Output Input 4 PriorityUsing the Paging Mic Using the Ambient MicSetting the Gain Setting the VOX ThresholdUsing the Local MIC/LINE Input Ambient Mic Calibration and PlacementUsing the PRE OUT/AMP Connections Using the Remote ConnectionUsing the RS485 Connection Zone a OutputUpgrading the Software Using the SPLinker Sound Palette ControllerUsing a 3rd Party Control System Specifications SP1200 Block DiagramSP1200 Specifications Power Amplifier SectionService Information Appendix a Default SettingsPress 2 on Power Up Ambient Mic Preamp Metering Appendix B Button Modes SP1200 Button ModesAppendix C Voltage Conversion Mackie Industrial