Mackie user service Specifications, SP1200 Block Diagram

Page 23

5. Specifications

SP1200 Block Diagram

DIRECT L OUTPUT R

L

INPUT 1

R

L

INPUT 2

R

L

INPUT 3

R

L

INPUT 4

R

BUS

 

 

 

ASSIGN

 

 

 

 

+

 

 

 

TO EXPANSION I/O

 

 

 

LOCAL/REMOTE

+

 

+

FROM

DIGITALLY

+

 

EXPANSION

 

CONTROLLED

I/O

ATTENUATORS

 

 

+

 

+

LOCAL/REMOTE

FROM

 

+

 

 

EXPANSION

 

 

I/O

 

 

+

BUS

TO EXPANSION I/O

 

ASSIGN

+

 

 

+

+

LOCAL/REMOTE

FROM

 

+

 

 

EXPANSION

 

 

I/O

 

 

+

 

+

LOCAL/REMOTE

+

FROM

 

 

EXPANSION

 

 

I/O

 

 

+

BUS

TO EXPANSION I/O

 

ASSIGN

+

 

 

+

+

LOCAL/REMOTE

+

FROM

 

 

EXPANSION

 

 

I/O

 

 

+

 

+

LOCAL/REMOTE

FROM

 

+

 

 

EXPANSION

 

 

I/O

 

 

+

BUS

TO EXPANSION I/O

 

ASSIGN

+

 

 

+

+

LOCAL/REMOTE

FROM

 

+

 

 

EXPANSION

 

 

I/O

 

 

+

 

+

LOCAL/REMOTE

+

FROM

 

 

EXPANSION

 

 

I/O

 

 

+

TO EXPANSION I/O

 

 

3

 

 

0

 

 

3

WOODINVILLE

REDMOND

6

9

 

FROM P

 

 

15

 

MACKIE

30

 

INDUSTRIAL

 

55

 

 

 

PROGRAM EQ

J6

 

ADC

TO P

 

 

 

 

 

EQ

 

 

 

 

LO

MID FREQ HI

BYPASS

 

J4

 

 

 

 

 

 

INSERT

 

 

80

12K

 

DIGITALLY

(INTERNAL

 

 

 

FOR OPTIONAL

 

 

 

 

 

CONTROLLED

 

 

 

 

 

DSP CARD)

 

 

 

 

 

ATTENUATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE A

 

 

 

 

 

 

PRE OUT

VOX

TO P

 

 

 

 

 

ACTIVATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V+

 

 

 

 

ZONE A

 

 

 

 

 

 

AMP IN

 

 

 

 

 

 

 

 

FROM

 

LEFT/ZONE A

 

 

 

OVERLOAD

TEMP

 

+24VDC

GAIN

PHANTOM

+40dB

2

 

1

 

PAGING MIC 3

 

1

GAIN

 

 

+40dB

3

 

+24VDC

GAIN

 

PHANTOM

+40dB

1

 

MIC/LINE

 

INPUT A

 

3

 

 

GAIN

+24VDC

+40dB

 

GAIN

+

VOX

GAIN

LO HI

80 12K

BUS

ASSIGN

TO EXPANSION I/O

 

 

MIC

 

 

+ —

 

(TO P)

 

 

 

 

PAGING

 

 

MIC VOX

 

LO

HI

 

80

12K

ZONE A

PAGE MIC

 

ALL CALL

SWITCH

GND

CONTROL

TO EXPANSION I/O

SENSOR

 

 

 

 

 

 

 

OUTPUT

(ON HEATSINK)

 

 

 

 

 

 

 

V—

 

 

 

 

 

+

 

 

PROTECTION

 

 

 

 

 

 

 

 

 

 

V+

 

 

 

 

 

 

 

 

 

70V/100V

 

 

 

 

 

V—

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXPANSION IN

 

 

 

 

 

25

13

 

 

 

 

+15VDC (w/J3 INSTALLED)

–15VDC (w/J2 INSTALLED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGING MIC CONTROL

N/C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGING MIC (–)

PAGING MIC (+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 4 RIGHT (–)

INPUT 4 RIGHT (+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 4 LEFT (–)

INPUT 4 LEFT (+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

INPUT 3 RIGHT (–)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 3 RIGHT (+)

INPUT 3 LEFT (–)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 3 LEFT (+)

GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 2 RIGHT (–)

INPUT 2 RIGHT (+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 2 LEFT (–)

INPUT 2 LEFT (+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

INPUT 1 RIGHT (–)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHANTOM

AMBIENT MIC 1

(ZONE A)

3

INTERNAL

TRIM

 

ADC

 

TO P

 

 

 

 

 

 

INPUT 1 LEFT (–)

 

 

 

INPUT 1 RIGHT (+)

 

 

 

 

 

 

INPUT 1 LEFT (+)

14

1

 

 

 

 

25

13

+15VDC (w/J3 INSTALLED)

–15VDC (w/J2 INSTALLED)

 

 

 

 

 

 

PAGING MIC CONTROL

N/C

 

 

 

 

 

 

PAGING MIC (–)

PAGING MIC (+)

 

 

 

 

 

 

INPUT 4 RIGHT (–)

INPUT 4 RIGHT (+)

 

 

 

 

 

 

INPUT 4 LEFT (–)

INPUT 4 LEFT (+)

 

 

 

 

 

 

GROUND

INPUT 3 RIGHT (–)

 

 

 

 

 

 

INPUT 3 RIGHT (+)

INPUT 3 LEFT (–)

 

 

 

 

 

 

INPUT 3 LEFT (+)

GROUND

 

 

 

 

 

 

INPUT 2 RIGHT (–)

INPUT 2 RIGHT (+)

 

 

 

 

 

 

INPUT 2 LEFT (–)

INPUT 2 LEFT (+)

 

 

 

ATTENUATOR

CONTROL

(FROM P)

MACKIE INDUSTRIAL

INPUT 1 RIGHT (–)

 

 

 

GROUND

 

 

 

 

 

 

SP1200

 

 

 

INPUT 1 RIGHT (+)

INPUT 1 LEFT (–)

 

 

 

 

 

 

INPUT 1 LEFT (+)

14

1

BLOCK DIAGRAM

 

 

 

 

 

 

 

 

 

(#01.02.01.DF)

 

EXPANSION OUT

 

SP1200 – 23

Image 23
Contents Paging MIC PowerOutput Suitable For Class 2 Wiring OL onTable of Contents Safety InstructionsIntroduction Key FeaturesRear Panel Features Front Panel FeaturesOutput Suitable LOW High PriorityRisk of Fire Replace with Same Type Fuse and Rating Do not Open Avis Risque DE Choc Electrique NE PAS OuvrirTypical Monaural Application InstallationApplication Diagrams Paging Program EQ Multiple SP1200s-Multiple Zones-Shared SourcesProgram Inputs Paging MIC Local InputsExpansion Expansion OUT Output Expansion with Local MicExpansion Expansion OUT Direct Room Combining-ZonesPort Comm Remote BUS Outputs RecordApplications Tips on Installing and Using the SP1200-Plan AheadConnections Connecting the Program SourcesConnecting the Microphones Connecting the SpeakersConnecting the Remote Bus Connecting the Expansion BusBus Assign Internal SettingsConnecting the RS485 Serial Port EQ Bypass 70V/100V/8 Ohm SettingsVoltage Conversion AC Power ConsiderationsThermal Considerations SP1200 Quick Start External Switch SettingsInternal Switch and Jumper Settings OperationRS485 Local MIC/LINE InputAmbient MIC Input RemoteInput 4 Priority Using InputsUsing the 3-Band EQ Input 1 and the Direct OutputSetting the VOX Threshold Using the Paging MicUsing the Ambient Mic Setting the GainAmbient Mic Calibration and Placement Using the Local MIC/LINE InputZone a Output Using the PRE OUT/AMP ConnectionsUsing the Remote Connection Using the RS485 ConnectionUpgrading the Software Using the SPLinker Sound Palette ControllerUsing a 3rd Party Control System SP1200 Block Diagram SpecificationsPower Amplifier Section SP1200 SpecificationsAppendix a Default Settings Service InformationAppendix B Button Modes SP1200 Button Modes Press 2 on Power Up Ambient Mic Preamp MeteringAppendix C Voltage Conversion Mackie Industrial