Linksys WET200 manual Administration Snmp, Administration Factory Defaults

Page 23

Chapter 6

Advanced Configuration

Web HTTPS Access  If you want to enable https access, select Enabled. The default setting is Disabled.

Click Apply to apply your changes, or click Cancel to cancel your changes.

Administration > SNMP

This screen is used to configure Simple Network Management Protocol (SNMP), a popular network monitoring and management protocol.

Administration > SNMP

SNMP  To disable SNMP, leave Disabled selected (default) . To enable SNMP, select Enabled, then select the type of SNMP to use, either SNMP V1 & V2 or SNMP V3.

Device Name  Enter the name of the Wireless Bridge. Contact  Enter the contact information for the Bridge. Location  Enter the location of the Wireless Bridge.

SNMP V.3 Username  Enter the username for the SNMP V3 administrator who will access and manage the MIB objects.

Authentication Password  Enter the authentication password for the SNMP V3 administrator. The password must be at least 8 characters in length.

Privacy Password  Enter the privacy password for the SNMP V3 administrator. The password must be at least 8 characters in length.

Get Community  Enter the name of your Get community. Set Community  Enter the name of your Set community.

SNMP Trap-Community Enter the name of your Trap community.

SNMP-Trusted Host  Enter the IP address of your Trusted host. To have the Access Point respond to SNMP messages from every host in your LAN, enter 0.0.0.0.

SNMP Trap-Destination Enter the destination IP address for traps. To prevent traps from being sent to any of your LAN hosts, enter 0.0.0.0.

Administration > Configuration Management

Administration > Configuration Management

This screen lets you save the system configuration to a file as well as restore the system configuration from a previously saved file.

To save the configuration, click Save Configuration To File, then follow the prompts to save the file to your computer.

To restore the configuration from a file, enter the name of the file or click Browse to locate it, then click Apply.

Administration > Factory Defaults

This screen is used to restore the Bridge’s factory default settings. When you do this, you will lose all previously configured settings and cannot recover that configuration unless you have saved it using the Configuration Management screen.

Administration > Factory Defaults

Select Yes next to Restore Factory Defaults, then click Apply to restore the defaults and restart the Bridge.

Wireless-G Business Ethernet Bridge

19

Image 23
Contents Wireless-G Business Ethernet Bridge Online Resources About This GuideAbout This Guide Icon DescriptionsTable of Contents Appendix E Regulatory Information Appendix a Wireless Security ChecklistAppendix B Glossary Chapter Introduction ChapterNetwork Layout Chapter Planning Your Wireless NetworkNetwork Topology Example of WET200 in Ad-Hoc Mode Back Panel Chapter Product OverviewProduct Overview Front PanelOverview Chapter InstallationInstallation Placement OptionsWall-Mount Option InstallationWireless Chapter Quick Configuration OverviewAccessing the Web-Based Utility SetupSystem Status SwitchAdministration Setup Chapter Advanced ConfigurationAdvanced Configuration Wireless Site Survey WirelessWireless Basic Settings WPA-Personal aka WPA-PSK Wireless Wireless SecurityWPA2-Enterprise WPA2-PersonalWPA-Enterprise Switch Port Management SwitchWireless Advanced Settings Port Mirroring Setting Switch Port MirroringSwitch Vlan 802.1Q Port-Based Switch MAC Based ACLSwitch Spanning Tree Switch QoSAdministration Web Access AdministrationSwitch MAC Table Administration PasswordAdministration Factory Defaults Administration SnmpSystem Status System Status Administration Firmware UpgradeSystem Status Wireless Status System StatusPersonal, etc System Status Port StatisticsAd-Hoc General Network Security Guidelines Appendix a Wireless Security ChecklistWireless Security Checklist Appendix aGlossary Appendix BAppendix B Glossary Http HyperText Transport Protocol GlossarySnmp Simple Network Management Protocol a Smtp Simple Mail Transfer Protocol The standard eAppendix B Appendix C Appendix C SpecificationsSpecifications Appendix D Warranty InformationLimited Warranty Regulatory Information Appendix EAvis d’Industrie Canada Wireless DisclaimerDansk Danish Miljøinformation for kunder i EU Appendix E Norsk Norwegian Miljøinformasjon for kunder i EU Appendix E Contact Information Appendix F
Related manuals
Manual 3 pages 10.7 Kb

WET200 specifications

The Linksys WET200 Wireless-G Ethernet Bridge is designed for businesses looking to extend their network capabilities without the hassle of running Ethernet cables throughout their premises. This high-performance device effectively connects wired devices to a wireless network, providing businesses with efficient access to internet resources and network shares.

One of the standout features of the WET200 is its dual-functionality. It operates as both an Ethernet bridge and a wireless access point, allowing users to connect multiple wired devices, such as printers, servers, or computers, to a wireless network. This flexibility makes it an excellent choice for environments where network mobility is crucial, such as offices, retail establishments, and warehouses.

Another key characteristic of the Linksys WET200 is its support for Wireless-G technology, offering a maximum wireless speed of up to 54 Mbps. This ensures that data transfer between connected devices is quick and reliable while providing adequate bandwidth for various applications, including file sharing and streaming. The device also adheres to the IEEE 802.11b/g standard, which means it is compatible with a vast number of other wireless devices.

The WET200 features a simple setup process, aided by its web-based configuration interface. This user-friendly interface allows for easy management of networking settings, making it accessible for both novice and experienced users. Security is a significant consideration, and the WET200 includes robust encryption protocols such as WEP, WPA, and WPA2 to protect data transmission over the wireless network.

Moreover, the Ethernet Bridge is equipped with two 10/100 Ethernet ports, enabling connections to multiple wired devices simultaneously. Its compact design allows for easy placement in various locations, and the inclusion of LEDs provides users with real-time feedback on connectivity status.

Overall, the Linksys WET200 Wireless-G Ethernet Bridge stands out with its combination of performance, flexibility, and ease of use, making it an invaluable asset for businesses aiming to expand their wired network capabilities without compromising on performance or security. It's a smart solution for those who need to harness the power of wireless connectivity while ensuring that their critical wired devices remain connected to the network efficiently.