AirLink Raven II CDPD Modem

The Raven's rugged form factor is ideal for industrial and commercial applications that require real-time communications. The Raven provides wireless data communications for a variety of applications, such as oil and gas monitoring, public safety, automated signs, financial transactions, and security systems. It works with Remote Telemetry Units (RTUs) from several manufacturers (configuration instructions are detailed in the Raven/PinPoint User’s Manual).

Front of Raven IIBack of Raven II

1.2 Modem LEDs: What They Mean

When the modem is operating, the LEDs on the front panel provide the following information. (see Finding CDPD Service for more info):

LED

Description

 

 

 

Chan

The unit has acquired a valid CDPD channel (solid), or is

 

scanning for CDPD channels (flashing).

 

 

Link

A link has been established and a TEI (Temporary

 

Equipment Identifier) has been assigned.

 

 

Reg

The unit is registered on the CDPD network (solid), or has

 

switched to a non-preferred side (flashing).

 

 

RSSI

Flash patterns identify different RSSI levels in dBm:

 

-69 and up

Solid ON [best reception]

 

-70 to -79

300 ms (fast blink)

 

-80 to -89

600 ms (medium blink)

 

-90 to -99

1200 ms (slow blink)

 

-100 to -113

Off [worst reception]

TxRx

The unit is transmitting/receiving blocks of data.

 

 

Err

Block errors on the forward or reverse channels.

 

 

 

Pwr

The unit is powered on.

 

 

 

 

Page 2

AirLink Communications, Inc.

Image 6
Contents AirLink Page Table of Contents Getting StartedPage What is CDPD? Cdpd NetworkFront of Raven IIBack of Raven Modem LEDs What They Mean DescriptionContacting the Cdpd Service Provider Configuring the ModemAirLink Raven II Cdpd Modem Select Don’t detect my modem…., then Next AirLink Raven II Cdpd Modem User’s Manual Select Start→Settings→Dial-Up Networking Creating the PPP ConnectionUser’s Manual Select the Server Types tab. Make the following selections Uncheck disable Use IP header compression Clear the User Name, Password and Domain field Uncheck disable Start terminal screen minimizedUser name and Password are blank Installing and Using Wireless ACE User’s Manual AirLink Raven II Cdpd Modem User’s Manual Finding Cdpd Service AirLinkRegistration Problems Troubleshooting Error 629 or Error Adding the Modem in Windows for moreMounting the Raven Raven II Mounted in Mounting BracketSnap-in Mounting Bracket Connecting the power cable Connecting the antennaConnecting the serial cable Grounding the Raven CaseRTU RTU to Raven II setup Modem Technical Specifications Additional InformationMore Information Info@airlink.comAirLink Raven II Cdpd Modem