Honeywell 4800dr manual BEPBIP0

Page 110

 

Setting

Serial

 

Selection

Command

Page

* Indicates default

# Indicates a

 

 

 

 

numeric entry

 

 

 

 

 

 

 

 

 

Beeper Duration - Good Read

*Normal Beep

BEPBIP0

3-2

 

 

 

 

 

Short Beep

BEPBIP1

3-2

 

 

 

 

LED - Good Read

Off

BEPLED0

3-2

 

 

 

 

 

*On

BEPLED1

3-2

 

 

 

 

LED - Indicator State

*Off

BEPPOI0

3-2

 

 

 

 

 

On

BEPPOI1

3-2

 

 

 

 

Number of Beeps - Good Read

*1

BEPRPT1

3-2

 

 

 

 

 

Range 1 - 9

BEPRPT#

3-2

 

 

 

 

Good Read Delay

*No Delay

DLYGRD0

3-3

 

 

 

 

 

Short Delay (500 ms)

DLYGRD500

3-3

 

 

 

 

 

Medium Delay (1000 ms)

DLYGRD1000

3-3

 

 

 

 

 

Long Delay (1500 ms)

DLYGRD1500

3-3

 

 

 

 

User-Specified Good Read Delay

Range 0 - 30,000 ms

DLYGRD#####

3-3

 

 

 

 

Manual/Serial Trigger

*Manual/Serial Trigger Mode

TRGMOD0

3-3

 

 

 

 

 

Read Time-Out

TRGSTO####

3-4

 

(0 - 300,000 ms) *30,000

 

 

 

 

 

 

 

 

Scan Stand

Scan Stand Mode

TRGMOD4

3-4

 

 

 

 

 

Scan Stand Symbol

FNC3

3-4

 

 

 

 

Presentation

Presentation Mode

TRGMOD3

3-4

 

 

 

 

Presentation Sensitivity

Range 0-20 (*1)

TRGPMS##

3-5

 

 

 

 

Hands Free Time-Out

Range 0 - 300,000 ms

TRG-

3-5

 

 

PTO######

 

 

 

 

 

Reread Delay

Short (500 ms)

DLYRRD500

3-5

 

 

 

 

 

*Medium (750 ms)

DLYRR750

3-5

 

 

 

 

 

Long (1000 ms)

DLYRRD1000

3-5

 

 

 

 

 

Extra Long (2000 ms)

DLYRRD2000

3-5

 

 

 

 

User-Specified Reread Delay

Range 0 - 30,000 ms

DLYRRD#####

3-6

 

 

 

 

LED Power Level

Off

PWRLDC0

3-6

 

 

 

 

 

Low (50%)

PWRLDC50

3-6

 

 

 

 

 

*High (100%)

PWRLDC100

3-6

 

 

 

 

Imager Time-Out

Range 0 - 999,999 ms

SDRTIM#####

3-6

 

(*60,000 ms)

#

 

 

 

 

 

Aimer Delay

200 milliseconds

SCNDLY200

3-7

 

 

 

 

 

400 milliseconds

SCNDLY400

3-7

 

 

 

 

 

*Off (no delay)

SCNDLY0

3-7

 

 

 

 

User-Specified Aimer Delay

Range 0 - 4,000 ms

SCNDLY####

3-7

 

 

 

 

Aimer Mode

Off

SCNAIM0

3-7

 

 

 

 

 

Interlaced

SCNAIM2

3-7

 

 

 

 

10 - 6

Image 110
Contents 4800dr Disclaimer Table of Contents Data Editing UPC-A UPC-A/EAN-13 Interface Keys Product Specifications OCR Programming Chart About This Manual Connecting the Document Reader with USBGetting Started Unpacking the Document ReaderConnecting the Document Reader with TTL-232 Serial Port USB Connection Supported TerminalsProgramming the Interface Plug and Play IBM SurePosUSB PC or Macintosh Keyboard USB COM Port EmulationTTL-232 Serial Port Connection Aligning the Document Reader TrayReading Techniques Using the Imager Out of the StandLinear barcodes 2D Matrix symbols Terminal Interfaces Keyboard CountryKeyboard Style Keyboard CountryKeyboard Modifiers TTL-232 Baud Rate RS-232 Handshaking RS-232 Word Length Data Bits, Stop Bits, and ParityTTL-232 Receiver Time-Out Page Output Good Read IndicatorsBeeper Volume Good Read Beeper Good ReadLED Good Read LED Indicator StateBeeper Duration Good Read Number of Beeps Good ReadTrigger Modes Good Read DelayUser-Specified Good Read Delay Manual/Serial TriggerScan Stand Symbol Scan Stand ModePresentation Mode Presentation Sensitivity Reread DelayHands Free Time-Out Imager Time-Out User-Specified Reread DelayLED Power Level User-Specified Aimer Delay Aimer DelayAimer Mode CenteringTom and Right Decode Window Decode Search Mode Preferred SymbologyPreferred Symbology Time-out High Priority SymbologyLow Priority Symbology Preferred Symbology DefaultOutput Sequence Editor Output Sequence OverviewRequire Output Sequence Output Sequence Examples SeqblkMultiple Symbols Video Reverse Print WeightNo Read Mandatory Alignment FlagWorking Orientation Points to Keep In Mind Data EditingPrefix/Suffix Overview To Clear One or All Prefixes or Suffixes Scan the Add Prefix or Add Suffix symbolTo Add a Prefix or Suffix Scan Add SuffixPrefix Selections To Add a Carriage Return Suffix to all SymbologiesScan the Clear One Prefix or Clear One Suffix symbol Suffix SelectionsUser Specified Intercharacter Delay Intercharacter, Interfunction, and Intermessage DelaysIntercharacter Delay Function Code TransmitInterfunction Delay Intermessage DelayPage Data Format Editor Introduction Scan the Enter Data Format symbol Primary/Alternate FormatData Formatting To Add a Data FormatOther Programming Selections Data Format Editor CommandsEditor Commands Clear One Data FormatMove Commands Alternate Data Formats Data Format EditorData Formatter Alternate Data Format Page Symbologies MSICodabar Check Character Message Length DescriptionCodabar Start/Stop Characters Codabar Concatenation Codabar Message LengthCode 39 Start/Stop Characters Code 39 Check CharacterCode 32 Pharmaceutical Paraf Code 39 Message LengthCode 39 Append Full Ascii Code 39 CodeCheck Digit Interleaved 2 of 5 Message LengthCode 93 Message Length Code 93 CodeStraight 2 of 5 Industrial Message Length Straight 2 of 5 Iata Straight 2 of 5 Iata Message LengthMatrix 2 of 5 Message Length Isbt 128 Concatenation Check Digits RequiredCode 11 Message Length Code 128 Message Length Code 128 CodeTelepen Output Telepen Message LengthUPC-A Check Digit UPC-A Number SystemUPC-A Addenda Separator UPC-A AddendaUPC-A Addenda Required UPC-E0 Addenda Separator UPC-E0 ExpandUPC-E0 Addenda Required UPC-E0 Addenda UPC-E0 Check DigitUPC-E0 Number System EAN/JAN-13 Check Digit EAN/JAN-13 AddendaIsbn Translate EAN/JAN-13 Addenda RequiredEAN/JAN-13 Addenda Separator EAN/JAN-8 Check Digit EAN/JAN-8 AddendaMSI Check Character EAN/JAN-8 Addenda RequiredEAN/JAN-8 Addenda Separator MSI Message Length Plessey Message LengthGS1 DataBar Expanded Message Length PosiCode a and B PosiCode Message LengthCodablock F Message Length Code 16K Message Length Code 49 Message Length Minimum Message Length Maximum Message Length Off Eanucc Composite Codes UPC/EAN VersionEanucc Emulation Eanucc Composite Code Message LengthPostnet Intelligent Mail BarcodeID-tag UPU 4-State Postnet Check DigitBritish Post Planet CodePlanet Code Check Digit Canadian PostAustralian Post Australian Post InterpretationChina Post Message Length Japanese PostChina Post Korea Post Korea Post Message LengthQR Code Message Length Data Matrix Message LengthMaxiCode Message Length Aztec Code Message LengthAztec Runes Page OCR Programming OCR FontsOCR Templates Currency FontCreating an OCR Template Template CharactersStringing Together Multiple Formats Creating Or Statements Adding SpacesOCR User-Defined Variables Reading Multi-Row OCROCR Check Character OCR Modulo 10 Check CharacterProgramming a User-Defined Check Character OCR User-Defined Check CharacterOCR Modulo 36 Check Character Scan the Enter OCR Check Character barcode, belowWeighting Options Weighted Modulo 10 Check CharacterOCR Isbn Application Example 0128454OCR Template Codes Exit SelectionsInterface Keys Keyboard Function RelationshipsSupported Interface Keys Ascii HEXUtilities Test Menu Resetting the Standard Product DefaultsShow Data Format 2D PQA Print Quality AssessmentVisual Xpress Operations ConfigureVisual Xpress Introduction Scan DataHeld Products-Visual Xpress Installing Visual Xpress from the WebImaging Query Commands Serial Programming CommandsMenu Command Syntax ConventionsResponses Concatenation of Multiple CommandsExamples of Query Commands Enter cbr? Response CBRENA1ACK Trigger CommandsEnter cbrena? Response CBRENA1ACK CK20ACKTerminal Interfaces Menu CommandsSetting Serial Selection Command Output Selections KBDNPS1BEPBIP0 DECWIN1 Symbologies Prefix/Suffix SelectionsCBRCCT0 CBRCCT1 C93DCP TELENA0 TELENA1 UPEAD21 MSICHK0 C49DFT PLNCKX1 OCR Selections Product Specifications Parameter SpecificationPage Standard Cable Pinouts Serial OutputPage Repairs MaintenanceMaintenance Troubleshooting To Replace the Interface CableDocument reader won’t read your barcode at all Page Technical Assistance Product Service and RepairCustomer Support Online Technical AssistanceNorth America Limited WarrantyOnline Product Service and Repair Assistance Page Page Appendix a Symbology ChartSymbology Possible AIM ID Code ID hex Modifiers mOCR-B1 Ascii Conversion Chart Code Hex CharCode Page Mapping of Printed Barcodes Code Standard DescriptionPage Page Page Sample Symbols QR Code OCR Programming Chart Discard Save Programming Chart Save Discard Honeywell
Related manuals
Manual 2 pages 56.38 Kb