Metrologic Instruments MS951 RS-232 Parameter Scanning Control DTR Signal, DE Disable Command

Page 18

Recall Defaults

D F 1

RS-232 Parameter - Scanning Control (DTR Signal)

When the DTR (Data Terminal Ready) input is enabled, the scanner will not transmit unless an active (+12V) DTR signal is present on the scanner’s DTR input pin. The scanner can be disabled by making DTR inactive (-12V) at the DTR input pin.

The DTR Scan Disable feature will prevent any scanning when the Enable DTR input feature is chosen. Before enabling the Enable DTR Scan Disable feature, first scan the EN- ABLE DTR INPUT bar code. To turn off this feature, scan the Recall Defaults bar code.

Enable DTR Input

H H 3

** Disable DTR Input

H H 4

Enable DTR Scan Disable

R 3 2

"DE" Disable Command

Enable "DE"

Disable Command

R 9 4

When this option is enabled, the scanner will stop scanning when it receives an ASCII "D"from the host device. Scanning will resume when the scanner receives an ASCII "E". This feature will only work with RS-232 communication.

*Disable "DE" Disable Command

R 9 5

When this option is chosen, the scanner will not stop scanning when it receives an ASCII "D" from the host device.

13

Image 18
Contents Metrologic INSTRUMENTS, INC Locations Table of Contents Page Page Scope of the MS951 Programming Guide Programming the Scanner Enter Program Mode Recall DefaultsLaser Activation Range Laser OperationSame Symbol Re-Scan Identical Symbol Re-Scan IndicatorVs 2 Scan Buffers Decode Options Beeper Tones Audible Indicators for Communication Timeouts RS-232 Interface RS-232 Parameter Baud RateRS-232 Parameter Parity RS-232 Parameter Data BitsRS-232 Parameter Hardware Handshaking RS-232 Parameter Software HandshakingIntercharacter Delay RS-232 Parameter Scanning Control DTR Signal DE Disable CommandLongitudinal Redundancy Check LRC Record Header/Terminator SelectSTX Prefix Off UPC/EAN Identifiers Keyboard Wedge KB Interface KB Parameter Keyboard TypeKB Parameter Keyboard Country Type Recall Defaults Reserved KB Parameter Caps Lock Mode KB Parameter Alt ModeKB Parameter Inter Scan Code Delay AT and PS/2 Modes KB Parameter XT Clean-Up BitWhen this option is on, the scanner will transmit a TAB Ascii 09H after each bar code KB Parameter Special Features Ocia Options IBM 46XX Parameter Inter Record Delay IBM 46XX OptionsLight Pen Options Light Pen Emulation Feature Code Type SelectionsPage Enable Code Disable Code Code Length Minimum Feature Minimum Code Length for All Code TypesUPC/EAN Code UPC-A OptionsUPC-E Options Disable 5 Digit Supps UCC Supplemental OptionsSupplemental Isbn Options Coupon CodeCode Ner will scan Code 39 bar codesEnable Clsi Editing Do Not Transmit Start/Stop CodabarInterleaved 2 of 5 ITF Interleaved 2 of 5 ITF Symbol Lengths Digits Recall Defaults Digits ITF Minimum Symbol Length Test MSI Plessey Check DigitUK Plessey Options Some UK librariesScanPal Data Collector Test ModesSpecial Features Way to disable this feature is by Locks on 16, 20, 23, 28 and 30 character bar codes User Programmable Prefix and Suffix ID Characters RB0 RB9 Bar Codes Ascii Reference Table HEX Value Decimal Character Less than Letter O 104 PC Extended Reference Key Tables PC Extended Key Reference Tables Function keys F1 F12 and other keys No E0H requiredReserved Codes Code Assigned FunctionRAA Page Page Page Page Page Page Page Page Page Page Disclaimer DisclaimerIndex ACK/NAKNewcode UPC-A

MS951 specifications

The Metrologic Instruments MS951 is a versatile, high-performance handheld laser scanner designed for a wide range of applications in retail and industrial settings. Featuring an advanced laser scanning technology, the MS951 provides exceptional speed and accuracy, making it ideal for environments that require quick and efficient barcode scanning.

One of the main features of the MS951 is its aggressive scan rate. Capable of reading barcodes at a remarkable rate of up to 300 scans per second, this scanner minimizes the time spent on each transaction, thus improving overall operational efficiency. The MS951 is specifically engineered to decode various barcode symbologies, including popular formats like UPC, EAN, and PDF417, ensuring broad compatibility for users.

The MS951 incorporates advanced laser technology, which enhances its performance in challenging scanning conditions. The precise laser beam allows it to read damaged, faded, or poorly printed barcodes with ease. This reliability is critical in busy retail environments where quick identification of products is necessary.

Another notable characteristic of the MS951 is its ergonomic design. Weighing approximately 6 ounces, it is lightweight and easy to handle, allowing for extended periods of use without causing discomfort to the operator. Additionally, the scanner features a comfortable grip, making it intuitive to use during long scanning sessions.

The MS951 is also equipped with an impressive range of connectivity options. It supports USB, RS-232, and keyboard wedge interfaces, enabling seamless integration into existing systems. This flexibility allows users to connect the scanner to various POS systems and computers without hassle.

Durability is another attribute that sets the MS951 apart. Constructed to withstand the rigors of daily use, it is designed to resist drops from a height of up to five feet, safeguarding it against accidental falls. This ruggedness ensures a longer lifespan and reduces the need for frequent replacements.

In conclusion, the Metrologic Instruments MS951 embodies a perfect blend of speed, accuracy, and durability, making it an excellent choice for businesses that require a reliable handheld laser scanner. Its advanced technology, ergonomic design, and versatile connectivity options position it as an essential tool for improving productivity in both retail and industrial applications. With the MS951 in hand, users can expect enhanced performance and efficient operations, ultimately driving business success.