Metrologic Instruments MS951 manual UPC-E Options

Page 38

Recall Defaults

D F 1

UPC-E Options

Expand UPC-E

E X 1

UPC-E Check Digit On

When this option is selected, the scanner will expand UPC-E to the 12 digit equivalent UPC-A.

** Do Not Expand UPC-E

E X 2

When this option is on, the scanner will transmit the UPC-E check digit.

C K 2

** UPC-E Check Digit Off

C K 1

UPC-E Leading 0 On

When this option is on, the scanner will output a zero before each UPC-E bar code.

L Z 1

** UPC-E Leading 0 Off

L Z 2

Disable EAN-8 Check Digit Transmission

R 3 6

** Enable EAN-8 Check Digit Transmission

R 3 7

Disable EAN-13 Check Digit Transmission

R 3 8

** Enable EAN-13 Check Digit Transmission

R 3 9

33

Image 38
Contents Metrologic INSTRUMENTS, INC Locations Table of Contents Page Page Scope of the MS951 Programming Guide Programming the Scanner Enter Program Mode Recall DefaultsLaser Activation Range Laser OperationVs 2 Scan Buffers Same Symbol Re-ScanIdentical Symbol Re-Scan Indicator Decode Options Beeper Tones Audible Indicators for Communication Timeouts RS-232 Interface RS-232 Parameter Baud RateRS-232 Parameter Parity RS-232 Parameter Data BitsRS-232 Parameter Hardware Handshaking RS-232 Parameter Software HandshakingIntercharacter Delay RS-232 Parameter Scanning Control DTR Signal DE Disable CommandLongitudinal Redundancy Check LRC Record Header/Terminator SelectSTX Prefix Off UPC/EAN Identifiers Keyboard Wedge KB Interface KB Parameter Keyboard TypeKB Parameter Keyboard Country Type Recall Defaults Reserved KB Parameter Caps Lock Mode KB Parameter Alt ModeKB Parameter Inter Scan Code Delay AT and PS/2 Modes KB Parameter XT Clean-Up BitWhen this option is on, the scanner will transmit a TAB Ascii 09H after each bar code KB Parameter Special Features Ocia Options IBM 46XX Parameter Inter Record Delay IBM 46XX OptionsLight Pen Options Light Pen Emulation Feature Code Type SelectionsPage Enable Code Disable Code Code Length Minimum Feature Minimum Code Length for All Code TypesUPC/EAN Code UPC-A OptionsUPC-E Options Disable 5 Digit Supps UCC Supplemental OptionsSupplemental Isbn Options Coupon CodeCode Ner will scan Code 39 bar codesEnable Clsi Editing Do Not Transmit Start/Stop CodabarInterleaved 2 of 5 ITF Interleaved 2 of 5 ITF Symbol Lengths Digits Recall Defaults Digits ITF Minimum Symbol Length Test MSI Plessey Check DigitUK Plessey Options Some UK librariesScanPal Data Collector Test ModesSpecial Features Way to disable this feature is by Locks on 16, 20, 23, 28 and 30 character bar codes User Programmable Prefix and Suffix ID Characters RB0 RB9 Bar Codes Ascii Reference Table HEX Value Decimal Character Less than Letter O 104 PC Extended Reference Key Tables PC Extended Key Reference Tables Function keys F1 F12 and other keys No E0H requiredReserved Codes Code Assigned FunctionRAA Page Page Page Page Page Page Page Page Page Page Disclaimer DisclaimerIndex ACK/NAKNewcode UPC-A