Altinex MT106-100 manual QZOOMC2U3

Page 12

MULTI-TASKER

Zoom value. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [QZOOMCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 2 of unit ID 3. View the current Quadrant Zoom value and make Quadrant Zoom the active control.

[QZOOMC2U3] 0

[QZOOMC2U3]

= STATUS/Current value

0

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

The zoom value will cycle through all five values repeatedly when using the [ + ] and [ - ] controls. For example, when the zoom value is at 4 and the increment command is sent, the next zoom value will be 0.

15. [BRIGnCi] - Set Value

This command sets the Brightness to an absolute value and makes the Brightness adjustment the active control.

Command Format: [BRIGnCiUy]

n = a value from 1 to 4

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 4 of unit ID 2. Set the Brightness to the value of 2 by sending the command [BRIG2C4U2].

16. [BRIGCi] - Status/Adjust

This command selects the Brightness adjustment and makes it the active control. It also returns the status of the current Brightness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [BRIGCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 2 of unit ID 3. View the current Brightness and make Brightness the active control.

[BRIGC2U3] 2

[BRIGC2U3]

= STATUS/Current value

2

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

17. [SHARPnCi] - Set Value

This command sets the Sharpness to an absolute value. It also makes the Sharpness adjustment the active control.

Command Format: [SHARPnCiUy]

n = a value from 1 to 8

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 4 of unit ID 2. Set the Sharpness to the value of 2 by sending the command [SHARP2C4U2].

18. [SHARPCi] - Status/Adjust

This command selects the Sharpness adjustment and makes it the active control. It is also used to return the status of the current Sharpness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [SHARPCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

11

Image 12
Contents MT106-100 Table of Contents Precautions / Safety Warnings InstallationCleaning GeneralAbout Your MT106-100 Technical Specifications MechanicalMT106-100 Description of MT106-100 Application Diagram ApplicationApplication Internal View of the MT106-100 Installing Your MT106-100 Description of CommandsOperation MIN Command Format HPOSnCiUy HPOSCi Status/AdjustVPOSCi Status/Adjust HPOSnCi Set ValueHSIZECi Status/Adjust VSIZECi Status/AdjustQZOOMCi Status/Adjust HSIZEC2U3QZOOMC2U3 SHARPC2U3 OUTBAR HelpTroubleshooting Guide Altinex Policy LED is Blinking REDNo Display