Altinex MT106-100 manual Min

Page 9

MULTI-TASKER

Example:

One MT106-100card is in slot #2 of unit 3. Sending the command [VERC2U3] to the Multi-Tasker™ Basic Enclosure will yield the following feedback:

MT106-100 690-0129-004

MT106-100 = card type

default values and place the card in NTSC format.

4. [ + ] or [ - ]

These commands allow the user to increase or decrease the selected attribute value. They must be used immediately following one of the following STATUS commands.

690-0129-004 = software version

2. [C]

This command receives the status of the card.

Command Format: [CnUi]

Cn = card ID (n = a slot # from 1 to 19)

(1-8 for MT100-101 or 1-4 for MT100-106)

Ui = unit id (i = 0 to 9) (refer to the MT100-100

user’s guide for explanation)

STATUS Command

[ HPOSCi ]

[ VPOSCi ]

[ HSIZECi ]

[ VSIZECi ]

[ BRIGCi ]

[ SHARPCi ]

[ QZOOMCi ]

MIN

Value

0

0

0

0

1

1

0

MAX Value

20

20

20

20

4

8

4

Default Value

10

10

10

13

1

5

0

Example:

There is one MT106-100 card in slot #2 of unit

3 set for NTSC outputs. Sending the command

[C2U3] to the Multi-Tasker™ will provide the

following feedback:

INPUT:640x480; OUTPUT:NTSC C02

INPUT:640x480

= Input resolution

OUTPUT:NTSC

= Output mode

C02

= card is in slot 2

If there is no card in slot #2 of unit 3, sending the [C2U3] command will not return any feedback from the card.

3.[CLR]

This command resets the card configuration to factory defaults.

Command Format: [CLRCi]

Ci = card ID (n = a slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)

Example:

There is an MT106-100 in slot 4 of unit 0. All controls are set to various levels and the output is in PAL mode. Sending the command [CLRC4] will set the level controls to their

Attempting to cycle past the minimum or maximum values will have no effect on the attribute's value. Only QZOOM will cycle back around through its range of values.

Any command other than [ + ] or [ - ] will reset the previous selection and the STATUS command will need to be reissued.

Example:

There is an MT106-100 in slot 4 of unit ID 2. The current Horizontal Position is set to a value of 10. Use the [ + ] and [ - ] controls to find the best horizontal position. Starting from 10, first increment the value to 12.

Next, decrement the value back down to 8 for the best picture.

[HPOSC4U2] 10 [ + ][ + ][ - ][ - ][ - ][ - ]

[HPOSC4U2]

= STATUS/Current value

10

= Feedback of current value

[ + ][ + ]

= Increment twice to 12

[ - ][ - ][ - ][ - ]

= Decrement 4 times to 8

[HPOSC4U2]

= STATUS/Current Value

8

= Feedback of new value

8

Image 9
Contents MT106-100 Table of Contents Installation Precautions / Safety WarningsCleaning GeneralAbout Your MT106-100 Technical Specifications MechanicalMT106-100 Description of MT106-100 Application Application DiagramApplication Internal View of the MT106-100 Installing Your MT106-100 Description of CommandsOperation MIN HPOSCi Status/Adjust Command Format HPOSnCiUyVPOSCi Status/Adjust HPOSnCi Set ValueVSIZECi Status/Adjust HSIZECi Status/AdjustQZOOMCi Status/Adjust HSIZEC2U3QZOOMC2U3 OUT SHARPC2U3BAR HelpTroubleshooting Guide Altinex Policy LED is Blinking REDNo Display