Altinex MT106-100 manual SHARPC2U3, Out, Bar, Help, 22. WR

Page 13

MULTI-TASKER

Example:

There is an MT106-100 in slot 2 of unit ID 3. View the current Sharpness and make Sharpness the active control.

[SHARPC2U3] 2

[SHARPC2U3]

= STATUS/Current value

2

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

19. [OUT]

This command selects the output signal format for the video signal. There are two modes to select, either NTSC or PAL.

Command Format: [OUTnCiUy]

n = format type (0=NTSC, 1=PAL)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

To change the format from the MT106-100 in slot 3 of unit ID 2, from PAL to NTSC, send the command [OUT0C3U2].

The default mode is NTSC.

20. [BAR]

The BAR command allows the user to choose among outputting the applied input video signal, a color test pattern or a grey scale test pattern.

Command Format: [BARnCiUy]

n

=

0 to 2

 

 

0

= Video

 

 

1

= Color Test Pattern

 

 

2

= Grey Scale Test Pattern

Ci

= card ID (i = slot number)

Uy

=

unit id (i = 0 to 9) (refer to the MT100-

 

 

100 user’s guide for explanation)

Example:

Supply a color test pattern from the MT106-100 in slot 4 of unit ID 0. Send the command [BAR1C4U0] to enable the color test pattern

output. In order to view the actual video signal again, send the command [BAR0C4U0].

21. [HELP]

In MTSetup.exe, this command displays a list of the commands available for the MT106-100 along with a brief description.

Command Format: [HELPCiUy]

Ci =card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100- 100 user’s guide for explanation)

22. [WR]

This command groups multiple cards in the Enclosure. Each unit contains a maximum of nine groups.

Command Format: [WRCn…GkUi]

Cn = card ID No. (n = slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)

Gk = group number (k = # from 1-9)

Ui = unit number (i = # from 0-9)

Example:

To group cards #1, 2, and 3 as group 5 of unit #1, send the command [WRC1C2C3G5U1]. After executing this command, cards 1, 2 and 3 will be grouped together as group 5 of unit 1.

23. [CLR]

This command clears the members for a single group or for all nine groups.

Command Format: [CLRGkUi]

Gk = group number (k = # from 1-9)

Ui = unit number (i = # from 0-9)

Example:

1)To clear group #1, send the [CLRG1U1] command. This command clears the members for the specified group only.

2)To clear all groups of unit 1, send the [CLRG[U1] command.

12

Image 13
Contents MT106-100 Table of Contents Installation Precautions / Safety WarningsCleaning GeneralMechanical About Your MT106-100 Technical SpecificationsMT106-100 Description of MT106-100 Application Application DiagramApplication Internal View of the MT106-100 Description of Commands Installing Your MT106-100Operation MIN HPOSCi Status/Adjust Command Format HPOSnCiUyVPOSCi Status/Adjust HPOSnCi Set ValueVSIZECi Status/Adjust HSIZECi Status/AdjustQZOOMCi Status/Adjust HSIZEC2U3QZOOMC2U3 OUT SHARPC2U3BAR HelpTroubleshooting Guide LED is Blinking RED Altinex PolicyNo Display