S T E P 1

Installing Plug-in Module CS-U

If Plug-in Module CS-U has already been installed according to the instructions in the Getting Started Guide that came with the scanner, there is no need to perform the following procedures. Proceed to Step 2, Scanning Preparations.

Caution

Before you can install Plug-in Module CS-U, you must have installed

PhotoDeluxe 2.0 or Photoshop (Ver. 3.0 or higher) on your hard disk.

Install this program before attempting to install Plug-in Module CS-U.

Operating Environment

Hardware

Power Macintosh G3 or iMac computers equipped with USB ports (Performance with Macintosh compatibles is not guaranteed)

Main Memory

32 MB or more recommended

Application Software

PhotoDeluxe 2.0

Adobe Photoshop (Ver. 3.0 or higher)

Display

16-tone grayscale-capable monitor (32,000-color-capable monitor recommended). Black and white and 4-tone monochrome monitors cannot be used.

System Software

System 8.5.1 or later (iMac computers running Macintosh System Software 8.5.1 require the iMac Update 1.1)

iMac Update 1.1 can be obtained from CD-ROMs included with Macintosh-related magazines and the iMac support page of the Apple Computer, Inc., web site.

13

Image 13
Contents Users Guide Getting Started How to Make Best Use of the ManualsWhere to Look How to Use this GuideAbout the Conventions Used in this Guide Table of Contents Appendices Adjusting and Editing Scanned ImagesControl Panel Features Adjusting and Editing Scanned Images Scanning ProceduresE P Scanning Preparations pSee the Results of Adjustments Immediately Dynamic Preview Plug-in Module CS-U Special FeaturesGamma Curve Adjusts Image Brightness Supports ColorSync 2.0 or higher Auto Tone CorrectionQuick Start Instructions Installing Plug-in Module CS-UStart Plug-in Module CS-U Start the Preview ScanSpecify the Area of the Image to be Scanned p Set the preferences, magnification and scan mode settingsClick on the Browser button Select the area to be scanned by clicking and draggingClick on the Scan button Scan the Image pSave the image with the application software, specifying a Folder, file name and file formatE P E P Installing Plug-in Module CS-UOperating Environment Click the Install the Software button E P ProceduresClick the Yes button to start the installation E P E P Scanning Preparations Buttons Display Plug-in Module CS-U Control PanelAdobe PhotoDeluxe E P Operating ProceduresAdobe Photoshop Set the original on the scanner document glass PreviewingClick on the Preview button Unit Set PreferencesE P Setting Basic Resolution E P Preview Window Size Preview Window Settings Dialog BoxE P Calibration Return to Default SettingsSelect the Prefs menu in the control panel Select the desired option from the pull-down menuSet Magnification Output Device Resolution= 360 dpi, Magnification= 100%Set the desired magnification factor on the control panel E P To Set the Magnification FactorBlack and White Mode Line Set Scan ModeBlack and White Mode Diffusion Dither Grayscale Mode 8-bitHigh Definition Color Color Mode 24-bitSelect the scan mode that you want To Set the Scan ModeTo Verify the Image Verify Image Before ScanningE P Scanning Position the pointer in the preview window Scan Area SettingsTo Zoom ZoomingSelect the area you want to enlarge with the zoom function To return to normal view, click the Zoom Out button Click on the Zoom In buttonTo Initiate the Scan ScanningSpecify the Scan Area To Save an Image Saving Scanned ImagesGrayscale Mode Color ModeBlack & White Mode Diffusion DitherHow to Interpret Histograms Using the Histogram Feature to Adjust Image ContrastHow to Adjust Histograms Click on the Histogram button E P To Adjust a HistogramClick the Auto button Click on the OK buttonSetting the Gamma Adjusting the Image with Gamma SettingsGamma Gamma =Contrast Brightness and Contrast SettingsBrightness Click the gamma button E P To Adjust the Brightness and ContrastClick the OK button CRT Type a Adjusting Gamma with the MenuCRT Type B CRT Type CClick the radio button for Menu Setting E P To Change the Gamma Value SettingsAdjusting the Gamma Value to Match the Display Gamma Value SettingsSending Output to a Printer Slider Manipulating the Graph Tone Curve SettingsE P To Edit the Tone Curve To Activate the ColorSync Function Auto Tone Correction ColorSyncDescreen ProcedureOpen the Image menu and select Descreen Set the threshold value in the Control Panel To Set the Threshold ValueTo Save Settings in a Settings File Saving / Recalling SettingsE P To Recall a Settings File Many special effects may be achieved with filters Editing Scanned ImagesOptical and Enhanced Resolutions Matching Scan Resolution to PurposeScanning Techniques Functional Specifications SpecificationsSystem Requirements Problem TroubleshootingClicked on the Plug-in Module CS-U control panel Scan button cannot be selected Error Message Error MessagesCause ResponseGlossary Image File ResolutionPreview ScannerIndex P E N D I C E S Helpdesk Canon Customer Support Help DeskOE-030AA 0799 CDS Canon Inc