Canon FB636U, FB630U To Set the Threshold Value, Set the threshold value in the Control Panel

Page 54

S T E P 4

Brightness Settings for Black & White Images (Threshold Value)

When the scan mode is set to Black & White (Line), the image brightness can be adjusted. The threshold value setting determines whether a half tone will be expressed as a black or a white data point. The possible threshold values range between 1 and 255. Below a given threshold value, all data is converted to black. Likewise, all data with a value above the threshold is converted to white. Accordingly, higher threshold values produce darker images while lower threshold values result in brighter images.

Threshold Value = 128 (Standard)

Threshold Value = 180

Threshold Value = 70

To Set the Threshold Value

Set the threshold value in the Control Panel.

The threshold value adjustment categories will only appear when the scan mode is set to Black & White (Line), the image brightness can be adjusted.

Drag the slider left or right or click on the left or right direction arrows to change the threshold value to the desired setting.

Click the arrow to restore the default values. (128)

The value in the box will change as the slider or direction arrows are moved. A value may also be input directly into the box without moving the slider.

Hint

The changes will be reflected in the preview image.

54

Image 54
Contents Users Guide How to Make Best Use of the Manuals Getting StartedHow to Use this Guide Where to LookAbout the Conventions Used in this Guide Table of Contents Adjusting and Editing Scanned Images AppendicesControl Panel Features E P Scanning ProceduresAdjusting and Editing Scanned Images Scanning Preparations pGamma Curve Adjusts Image Brightness Plug-in Module CS-U Special FeaturesSee the Results of Adjustments Immediately Dynamic Preview Supports ColorSync 2.0 or higher Auto Tone CorrectionStart Plug-in Module CS-U Installing Plug-in Module CS-UQuick Start Instructions Start the Preview ScanClick on the Browser button Set the preferences, magnification and scan mode settingsSpecify the Area of the Image to be Scanned p Select the area to be scanned by clicking and draggingSave the image with the application software, specifying a Scan the Image pClick on the Scan button Folder, file name and file formatE P Installing Plug-in Module CS-U E POperating Environment E P Procedures Click the Install the Software buttonClick the Yes button to start the installation E P E P Scanning Preparations Display Plug-in Module CS-U Control Panel ButtonsE P Operating Procedures Adobe PhotoDeluxeAdobe Photoshop Previewing Set the original on the scanner document glassClick on the Preview button Set Preferences UnitE P Setting Basic Resolution Preview Window Settings Dialog Box E P Preview Window SizeSelect the Prefs menu in the control panel Return to Default SettingsE P Calibration Select the desired option from the pull-down menuOutput Device Resolution= 360 dpi, Magnification= 100% Set MagnificationE P To Set the Magnification Factor Set the desired magnification factor on the control panelBlack and White Mode Diffusion Dither Set Scan ModeBlack and White Mode Line Grayscale Mode 8-bitColor Mode 24-bit High Definition ColorTo Set the Scan Mode Select the scan mode that you wantVerify Image Before Scanning To Verify the ImageE P Scanning Scan Area Settings Position the pointer in the preview windowZooming To ZoomSelect the area you want to enlarge with the zoom function Click on the Zoom In button To return to normal view, click the Zoom Out buttonScanning To Initiate the ScanSpecify the Scan Area Saving Scanned Images To Save an ImageBlack & White Mode Color ModeGrayscale Mode Diffusion DitherUsing the Histogram Feature to Adjust Image Contrast How to Interpret HistogramsHow to Adjust Histograms Click the Auto button E P To Adjust a HistogramClick on the Histogram button Click on the OK buttonAdjusting the Image with Gamma Settings Setting the GammaGamma = GammaBrightness and Contrast Settings ContrastBrightness E P To Adjust the Brightness and Contrast Click the gamma buttonClick the OK button CRT Type B Adjusting Gamma with the MenuCRT Type a CRT Type CE P To Change the Gamma Value Settings Click the radio button for Menu SettingGamma Value Settings Adjusting the Gamma Value to Match the DisplaySending Output to a Printer Slider Tone Curve Settings Manipulating the GraphE P To Edit the Tone Curve Auto Tone Correction ColorSync To Activate the ColorSync FunctionProcedure DescreenOpen the Image menu and select Descreen To Set the Threshold Value Set the threshold value in the Control PanelSaving / Recalling Settings To Save Settings in a Settings FileE P To Recall a Settings File Editing Scanned Images Many special effects may be achieved with filtersMatching Scan Resolution to Purpose Optical and Enhanced ResolutionsScanning Techniques Specifications Functional SpecificationsSystem Requirements Troubleshooting ProblemClicked on the Plug-in Module CS-U control panel Scan button cannot be selected Cause Error MessagesError Message ResponseGlossary Preview ResolutionImage File ScannerIndex P E N D I C E S Canon Customer Support Help Desk HelpdeskOE-030AA 0799 CDS Canon Inc