SPECIAL APPLICATION

7.[IN]

This command is used to select the PE1004CF input that will be directed to the plasma display’s active expansion input.

Command Format: [INnCi]

n= Input Number (n = 1, 2, 3 or 4) Ci = Unit ID (i = # from 0 to 99) Example:

Output the PE1004C’s CAT-5 #2 input to the plasma display input number 3. First, set the plasma to expansion input three. Then send the command [IN2] to output the PE1004CF’s CAT-5 #2 input to the plasma monitor.

REMEMBER: When an expansion input is selected on the monitor, its corresponding PE1004CF input is selected automatically.

8.[EQn]

This command is used to set the amount of video equalization when software equalization is selected, and to make it active for adjustments using the [+] and [ - ] commands.

Command Format: [EQnCi]

n= Equalization amount (n = # from 0 to 254) Ci = Unit ID (i = # from 0 to 99)

Example:

Set the video equalization level to 150 by sending the command [EQ150].

9.[EQ]

This command displays the current level of software equalization and makes it active for adjustments using the [+] and [ - ] commands.

Command Format: [EQCi]

Ci = Unit ID (i = # from 0 to 99) Example:

Check the video equalization level to by sending the command [EQ]. The system will return the following feedback for the previous example:

150

10.[ + ]

This command increments a selected property, in this case equalization, to be adjusted using RS-232 control.

Command Format: [ + ], [+k]

[+]= Increment level by one-step [+k] = Increment level by 'k' steps Example:

Select the equalization command by sending the command [EQ]. The current level is 150, but it is not the optimal value. After sending the following commands, an optimum level of 160 is obtained:

1.[EQ]

The current level is 10.

2.[+][+][+][+][+][+][+][+][+][+] or [ + 10 ]

The level is now 160 and no further adjustments are required.

11.[ - ]

This command decrements a selected property, in this case equalization, to be adjusted using RS-232 control.

Command Format: [ - ], [-k]

[-] = Decrement level by one-step [-k] = Decrement level by 'k' steps Example:

Select the equalization command by sending the command [EQ]. The current level is 160, but it is not the optimal value. After sending the following commands, an optimum level of 140 is obtained:

1.[EQ]

The current level is 160.

2.[ ] [ ] [ ] … [ ] or [20]

The level is now 140 and is no further adjustments are required.

400-0210-001

10

Image 11
Contents PE1004CF Table of Contents Precautions / Safety Warnings About Your PE1004CF Technical SpecificationsManual Input Selection Description of PE1004CF Application DiagramsDiagram 1 Input Selection Automatic Input Selection Diagram 2 Typical Setup Typical Application Diagram 3 Internal View PE1004CF Block Diagram Equalization Diagram 4 Switch SettingsRS-232 Control Installing Your PE1004CFDescription of Commands OperationStatus Freset10. + EQnTroubleshooting Guide Altinex Policy