Altinex MT106-101 manual Troubleshooting Guide, LED is not LIT, No Display

Page 15

MULTI-TASKER

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied MT106-101; however, we would like to offer suggestions for the following:

8.1 LED IS NOT LIT

8.2 LED IS BLINKING RED

8.3 NO DISPLAY

8.1 LED IS NOT LIT

Cause 1: Card cage is not plugged in.

Solution: Plug the card cage in. If the LED lights, the problem is solved. If the LED is still not ON, see Cause 2.

Cause 2: Card is not plugged in all the way.

Solution: Push the card in all the way. If the LED is still not ON, see Cause 3.

Cause 3: Card cage slot has a problem.

Solution 1: Test the card in other slots of the card cage. If the slot was damaged, the card may work in other slots. If other slots work and the LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2.

Solution 2: Take any other known good card with an LED and verify that the slot used is good by seeing if the other card’s LED lights in that slot. If it lights, then the original card may be the source of the problem. Call ALTINEX at (714) 990-2300.

8.2 LED IS BLINKING RED

Cause 1: The CPU on the card is not working properly.

Solution 1: Look at the card and verify that there is no damage. If there is no damage, see Solution 2.

Solution 2: Verify that all IC’s are seated in their sockets. If the LED is still blinking red, see Cause 2.

Cause 2: The card and its serial device are not communicating.

Solution 1: Turn the system OFF and then ON again. If there is still an error, see Cause 3.

Cause 3: RS485 communication error

Solution 1: Make sure that the card is pushed all the way into the slot. If there is still an error, see Solution 2.

Solution 2: Turn the system OFF and then ON again. If there is still an error, see Solution 3.

Solution 3: Call ALTINEX at (714) 990-2300.

8.3 NO DISPLAY

Cause 1: The source has a problem.

Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2.

Cause 2: The card output is not selected.

Solution: Select the card output. See RS-232 accessible commands in Section 7. If no display is present, see Cause 3.

Cause 3: Cable connections are incorrect.

Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4.

Cause 4: The display has a problem.

Solution: Make sure the display has power and is turned ON. If there is still no display, please call Altinex at (714) 990-2300.

14

Image 15
Contents MT106-101 Table of Contents General Precautions / Safety WarningsInstallation CleaningTechnical Specifications About Your MT106-101Mechanical Description of MT106-101 Application Application DiagramApplication 2 Internal View of MT106-101 Installing Your MT106-101 Description of CommandsOperation MT106-101 Command Format CnUiCommand Format CLRCi Command Format ONnCiUyStatus MIN MAX HSIZEnCi Set Value HSIZECi Status/AdjustVSIZECi Status/Adjust VPOSC2U3SHARPC2U3 COLORC2U3 Hpos Summary of Commands VERSIG CLRTroubleshooting Guide LED is not LITNo Display Toll Free 1-800-ALTINEX Altinex Policy