Altinex MT106-101 manual SHARPC2U3

Page 12

MULTI-TASKER

15. [BRIGnCi] - Set Value

This command selects the Brightness adjustment and makes it the active control. It also returns the status of the current Brightness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [BRIGnCiUy]

n = a value from 0 to 20 (Default = 10)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 4 of unit ID 2. Set the Brightness to the value of 2 by sending the command [BRIG2C4U2].

16. [BRIGCi] - Status/Adjust

This command selects the Brightness adjustment and makes it the active control. It is also used to return the value of the current Brightness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [BRIGCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 2 of unit ID 3. View the current Brightness and adjust the brightness for a good image.

[BRIGC2U3] 2

[BRIGC2U3]

= STATUS/Current value

2

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

17. [SHARPnCi] - Set Value

This command sets the Sharpness to an absolute value. It also makes the Sharpness adjustment the active control.

Command Format: [SHARPnCiUy]

n = a value from 0 to 3 (Default = 2)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 4 of unit ID 2. Set the Sharpness to the value of 2 by sending the command [SHARP2C4U2].

18. [SHARPCi] - Status/Adjust

This command selects the Sharpness adjustment and makes it the active control. It is also used to return the status of the current Sharpness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [SHARPCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 2 of unit ID 3. View the current Sharpness and adjust the sharpness for a clean, clear image.

[SHARPC2U3] 2

[SHARPC2U3]

= STATUS/Current value

2

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

19. [COLORnCi]

The COLOR command sets the Color to an absolute value. It also makes the Color adjustment the active control.

Command Format: [COLORnCiUy]

n = a value from 0 to 10 (Default = 10)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

If there is an MT106-101 in slot 4 of unit ID 2, the color may be set to a value of 2 by sending the command [COLOR2C4U2].

11

Image 12
Contents MT106-101 Table of Contents Precautions / Safety Warnings InstallationCleaning GeneralTechnical Specifications About Your MT106-101Mechanical Description of MT106-101 Application Diagram ApplicationApplication 2 Internal View of MT106-101 Installing Your MT106-101 Description of CommandsOperation Command Format CnUi Command Format CLRCiCommand Format ONnCiUy MT106-101Status MIN MAX HSIZECi Status/Adjust VSIZECi Status/AdjustVPOSC2U3 HSIZEnCi Set ValueSHARPC2U3 COLORC2U3 Summary of Commands VER SIGCLR HposTroubleshooting Guide LED is not LITNo Display Altinex Policy Toll Free 1-800-ALTINEX